10
49-5000712 Rev. 3
How to Install In Pre-Existing Wall Sleeve
1.
Identify the wall-sleeve brand for your installation, from the chart below.
Wall Sleeve Dimensions (inches)
Width
Height
Depth
White-Westinghouse
25-1/2
15-1/4
16, 17-1/2 or 22
Frigidaire
Carrier (52F Series)
GE/Hotpoint
26
15-5/8
15-7/8
Whirlpool
25-7/8
16-1/2
17-1/8 or 23
Fedders/Emerson
27
16-3/4
16-3/4 or 19-3/4
Sears/Kenmore
25-3/4
16-7/8
18-5/8
Carrier (51S Series)
Emerson/Fedders
26-3/4
15-3/4
15
Friedrich
27
16-3/4
16-3/4
NOTE:
All wall sleeves used to mount the new air conditioner must
be in sound structural condition and have a rear grille that securely
attaches to sleeve, or rear flange that serves as a stop for the air
conditioner.
IMPORTANT:
:KHQLQVWDOODWLRQLVFRPSOHWHUHSODFHPHQWXQLW0867
have a rearward slope as shown.
2.
Remove old air conditioner from wall sleeve and prepare wall sleeve as follows:
Ŷ&OHDQLQWHULRUGRQRWGLVWXUEVHDOV
Ŷ:DOOVOHHYHPXVWEHVHFXUHO\IDVWHQHGLQZDOOEHIRUHLQVWDOOLQJDLUFRQGLWLRQHU
. Drive more nails or screws
through sleeve, into wall, if needed.
Ŷ5HSDLUSDLQWLIQHHGHG
3.
If not pre-existing, drill a 1/8” hole to attach the supplied grounding wire to the
left side of the wall sleeve (see approximate hole location dimensions in the
LOOXVWUDWLRQEHORZ8VHWKHWRRWKHGZDVKHUDQGSRLQWHGVFUHZWRDWWDFKRQHHQG
of the supplied green striped ground wire to the inside of the wall sleeve. The
toothed washer must be between the eyelet of the wire and the wall sleeve.
BE
CAREFUL TO NOT OVERTIGHTEN THE SCREW.
Pull loose end of ground
wire out front of sleeve, and temporarily bend it down and around lower edge of
sleeve. This ground wire will later be attached to frame of air conditioner once it is installed.
4.
Prepare the wall sleeve for installation of the new unit per the following brand instructions.
1
Emerson
15” Deep
2
Fedders
19-3/4” Deep
3
Fedders or Friedrich
16-3/4” Deep
4
GE/Hotpoint
16-7/8” Deep
5
Sears or Carrier (51S Series)
18-5/8” Deep
6
Whirlpool
17-1/8” Deep
7
Whirlpool
23” Deep
8
White-Westinghouse/ Frigidaire/Carrier (52F Series)
16” + 17-1/2” Deep
9
White-Westinghouse/Frigidaire
22” Deep
5.
Identify your wall sleeve type and follow the instructions for that type in the following pages.
1
3
Max.
1/8
Hole
REAR
Wall Sleeve
UNIT
LEVEL
FRONT
to
3
INST
ALLA
TION INSTRUCTIONS
Installation Instructions