background image

8

49-5000492   Rev. 0  

INST

ALLA

TION INSTRUCTIONS

Installation Instructions

For more help, visit GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

 

IMPORTANT –

 

Save these 

instructions for local inspector’s use.

 

IMPORTANT –

 

Observe all 

governing codes and ordinances.

•  

Note to Installer 

– Be sure to leave these 

instructions with the consumer.

•  

Note to Consumer 

– Keep these instructions for 

future reference.

•  

Skill level 

– Installation of this appliance requires 

basic mechanical skills.

• Completion time 

±$SSUR[LPDWHO\KRXU

•  

We recommend that two people install this 

product.

•  

Proper installation is the responsibility of the 

installer.

•  

Product failure due to improper installation is not 

covered under the Warranty.

‡ <RX0867XVHSURSHULQVWDOODWLRQSURFHGXUHVDV

described in these instructions when installing this 

air conditioner.

  Power cord includes a current interrupter device. A 

TEST

 and 

RESET

 button are provided on the plug 

case. The device should be tested on a periodic 
basis by first pressing the 

TEST 

button and then the 

RESET 

button while plugged into the outlet. If the 

TEST 

button does not trip or if the 

RESET 

button 

will not stay engaged, discontinue use of the air 
conditioner and contact a qualified service technician.

ELECTRICAL REQUIREMENTS

Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this 
air conditioner.
Aluminum house wiring may present special 
problems—consult a qualified electrician.

For Existing Wall Sleeves

)RU([LVWLQJ:DOO6OHHYHV

Note that the air conditioner dimensions are:
Width-26”
Height-15 ¾”
Depth-18 ¼” (without front grille)
Depth-16” (rear of chassis to rear edge of front grille)
Install air conditioner according to these instructions 
to achieve the best performance. Installing this air 

FRQGLWLRQHULQH[LVWLQJVOHHYHVWKDWGRQRWDOORZIRU

proper fit or have proper outdoor grilles may affect 
performance and could void the manufacturer’s 
warranty. 

Parts Included

• Security bracket and screws for a 26” wall sleeve (2)
• Remote Control (1)

IMPORTANT NOTE

For optimal energy efficiency and performance, we 
recommend using the RAB26 or the RAB46B wall 
sleeves with the RAG13A rear grille.

CAUTION

Summary of Contents for AJCM10ACH

Page 1: ...www GEAppliances com FRANÇAIS For a French version of this manual visit our Website at www GEAppliances ca Pour un version français de ce manuel d utilisation veuillez visiter notre site web à l adresse www GEAppliances ca SAFETY INFORMATION 3 USING THE AIR CONDITIONER 4 CARE AND CLEANING 7 INSTALLATION INSTRUCTIONS 8 TROUBLESHOOTING TIPS 17 CONSUMER SUPPORT Warranty 19 Consumer Support 20 OWNER S...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...ditioner HOW TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO NOT use an adapter plug with this appliance The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of elec...

Page 4: ... Mode 8VH WR VHW 22 7 RQ VRPH PRGHOV 5 872 or FAN modes Indicator lights on the controls will show the mode selected 4 Temp Increase Decrease Pads 8VH WR VHW WHPSHUDWXUH ZKHQ LQ XWR RRO U RU HDW on some models mode 5 Fan Speed 8VH WR VHW WKH IDQ VSHHG DW 2 0 80 25 872 QGLFDWRU OLJKWV ZLOO VKRZ WKH VSHHG VHOHFWHG 6 Timer ON 8VH WR VHW WKH DLU FRQGLWLRQHU WR DXWRPDWLFDOO WXUQ ON from 5 to 24 hours l...

Page 5: ...en the time of TIMER ON is displayed press the Timer button again the TIMER OFF indicator light illuminates It indicates the Auto Stop program is initiated Ŷ 3UHVV RU KROG WKH 83 RU 2 1 EXWWRQ WR FKDQJH WKH Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start Ŷ The selected time will register in 5 second...

Page 6: ...t To open the ventilation port pull the lever forward The lever will lock in place To replace the air discharge louvers reverse the above procedure Remote Wall Thermostat Heat Cool models only All heat cool models are capable of being controlled by a 24 VAC remote wall thermostat The thermostat control connection board is located behind a metal cover on the right side of the metal chassis cover To...

Page 7: ... from the user interface press the rear of the tab and gently pull apart Front Grille Re installation 1 Reconnect the multi pin low voltage connector 2 Before engaging the 4 tabs on the inside top of the grille align the ventilation lever on the chassis into the mating slot on the inside of the discharge opening in the grille After ensuring proper alignment of the ventilation lever push the grille...

Page 8: ...sing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician ELECTRICAL REQUIREMENTS Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this ai...

Page 9: ...e slots in each side of the metal chassis cover When released pull out both bottom corners of the IURQW JULOOH DERXW WR H SRVH WKH WZR VFUHZ KROHV on the lower area of the metal chassis cover 5 Locate the 2 metal brackets stamped 26 that were included with the air conditioner Hook the short flange of the bracket behind the sleeve inside edge and rotate it so the long side can be pressed flat again...

Page 10: ...vers for better air distribution Front of unit is blocked by drapes blinds furniture etc which restricts air distribution Clear blockage in front of unit Doors windows registers etc may be open Close doors windows registers Unit recently turned on in hot room Allow additional time to remove stored heat from walls ceiling floor and furniture Air conditioner turns on and off rapidly Dirty air filter...

Page 11: ...ZDUUDQW H FOXGHV WKH FRVW RI VKLSSLQJ RU VHUYLFH calls to your home 6RPH VWDWHV GR QRW DOORZ WKH H FOXVLRQ RU OLPLWDWLRQ RI LQFLGHQWDO RU FRQVHTXHQWLDO GDPDJHV 7KLV OLPLWHG ZDUUDQW gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General W...

Page 12: ...UFKDVH D SSOLDQFHV H WHQGHG ZDUUDQW DQG OHDUQ DERXW VSHFLDO GLVFRXQWV WKDW DUH DYDLODEOH ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty or call 800 626 2224 during normal business hours CONSUMER SUPPORT Parts and Accessories Individuals qualified to service t...