The “Cool” circuit has an automatic 3 minute delayed 
start if the unit is turned off and on quickly. This prevents 
overheating of the compressor and possible circuit breaker 
tripping. The fan will continue to run during this time. 
There is a 2 second delay for the compressor to stop when 
selecting FAN ONLY/HEAT. This is to cover the possibility 

of having to roll through to select another mode. 
The control will maintain the set temperature within 1°F 
between 62°F and 86°F in cool or heat mode (on some 
models). 
After a power outage, the unit will remember last setting 
and return the unit to that setting when power is restore. 

Air Direction

Air directional louvers control air flow direction.
The louvers will allow you to direct the air flow up or down 
and left or right throughout the room as needed until the 
desired left/right direction is obtained. Pivot horizontal 
louvers until the desired up/down direction is obtained.

Ventilation

To open the ventilation port, remove the adjustable air discharge louvers by gently pulling forward the right end until 
it is released from the pivot point. Shift the louvers to the right to release the left end from its pivot point. To open the 
ventilation port, pull the lever forward. The lever will lock in place. To replace the air discharge louvers, reverse the 
above procedure

Remote Wall Thermostat (Heat/Cool models only)

All heat/cool models are capable of being controlled by a 
24 VAC remote wall thermostat. The thermostat control 
connection board is located behind a metal cover on the 
right side of the metal chassis cover. To open the cover, 
remove the Phillips head screw and lift from the slots at the 
bottom. To properly connect the wiring from a remote wall 
thermostat, follow these steps:
1.  Order the 8-pin connector from GE Appliances Service. 

Call 1-800-626-2002 and order WP26X24981. A 
connector is required for each unit being controlled by 
a wall thermostat

2.  Install the remote thermostat according to the 

directions included with it.

8VLQJZLUHQXWVLQFOXGHGZLWKWKHSLQFRQQHFWRU

connect the wiring from the wall thermostat per the 
following; (Proper connection of the wiring is critical. 
Improper hookups could result in damage to the air 
conditioner components and may not be covered by 
the product warranty) After properly making the wire 
nut connections, wrap the 7 connectors together with 
electrical tape and push them into the lower right 

FRUQHURIWKHFRQWUROER[RSHQLQJWRNHHSWKHPRXWRI

the way.

Connector Wire Color Codes

 

Thermostat Connections

Black 

   Common

White 

   Electric Heater

Yellow 

   Compressor

Blue 

    B terminal  

(heatpump models only)

Green 

   Fan High

Tan 

   Fan low

Red 

   24 VAC

Summary of Contents for AJCM10ACH

Page 1: ...www GEAppliances com FRANÇAIS For a French version of this manual visit our Website at www GEAppliances ca Pour un version français de ce manuel d utilisation veuillez visiter notre site web à l adresse www GEAppliances ca SAFETY INFORMATION 3 USING THE AIR CONDITIONER 4 CARE AND CLEANING 7 INSTALLATION INSTRUCTIONS 8 TROUBLESHOOTING TIPS 17 CONSUMER SUPPORT Warranty 19 Consumer Support 20 OWNER S...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...ditioner HOW TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO NOT use an adapter plug with this appliance The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of elec...

Page 4: ... Mode 8VH WR VHW 22 7 RQ VRPH PRGHOV 5 872 or FAN modes Indicator lights on the controls will show the mode selected 4 Temp Increase Decrease Pads 8VH WR VHW WHPSHUDWXUH ZKHQ LQ XWR RRO U RU HDW on some models mode 5 Fan Speed 8VH WR VHW WKH IDQ VSHHG DW 2 0 80 25 872 QGLFDWRU OLJKWV ZLOO VKRZ WKH VSHHG VHOHFWHG 6 Timer ON 8VH WR VHW WKH DLU FRQGLWLRQHU WR DXWRPDWLFDOO WXUQ ON from 5 to 24 hours l...

Page 5: ...en the time of TIMER ON is displayed press the Timer button again the TIMER OFF indicator light illuminates It indicates the Auto Stop program is initiated Ŷ 3UHVV RU KROG WKH 83 RU 2 1 EXWWRQ WR FKDQJH WKH Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start Ŷ The selected time will register in 5 second...

Page 6: ...t To open the ventilation port pull the lever forward The lever will lock in place To replace the air discharge louvers reverse the above procedure Remote Wall Thermostat Heat Cool models only All heat cool models are capable of being controlled by a 24 VAC remote wall thermostat The thermostat control connection board is located behind a metal cover on the right side of the metal chassis cover To...

Page 7: ... from the user interface press the rear of the tab and gently pull apart Front Grille Re installation 1 Reconnect the multi pin low voltage connector 2 Before engaging the 4 tabs on the inside top of the grille align the ventilation lever on the chassis into the mating slot on the inside of the discharge opening in the grille After ensuring proper alignment of the ventilation lever push the grille...

Page 8: ...sing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician ELECTRICAL REQUIREMENTS Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this ai...

Page 9: ...e slots in each side of the metal chassis cover When released pull out both bottom corners of the IURQW JULOOH DERXW WR H SRVH WKH WZR VFUHZ KROHV on the lower area of the metal chassis cover 5 Locate the 2 metal brackets stamped 26 that were included with the air conditioner Hook the short flange of the bracket behind the sleeve inside edge and rotate it so the long side can be pressed flat again...

Page 10: ...vers for better air distribution Front of unit is blocked by drapes blinds furniture etc which restricts air distribution Clear blockage in front of unit Doors windows registers etc may be open Close doors windows registers Unit recently turned on in hot room Allow additional time to remove stored heat from walls ceiling floor and furniture Air conditioner turns on and off rapidly Dirty air filter...

Page 11: ...ZDUUDQW H FOXGHV WKH FRVW RI VKLSSLQJ RU VHUYLFH calls to your home 6RPH VWDWHV GR QRW DOORZ WKH H FOXVLRQ RU OLPLWDWLRQ RI LQFLGHQWDO RU FRQVHTXHQWLDO GDPDJHV 7KLV OLPLWHG ZDUUDQW gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General W...

Page 12: ...UFKDVH D SSOLDQFHV H WHQGHG ZDUUDQW DQG OHDUQ DERXW VSHFLDO GLVFRXQWV WKDW DUH DYDLODEOH ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty or call 800 626 2224 during normal business hours CONSUMER SUPPORT Parts and Accessories Individuals qualified to service t...

Reviews: