background image

Printed in China

AJCS06 AJCS09 AJES10 AJEH12
AJCH08 AJES09 AJHS10 AJES12
AJCS08 AJCH10 AJCH12
AJHS08 AJCS10 AJCS12

What Is Not 
Covered

FULL ONE-YEAR WARRANTY

For one year from date of original pur-

chase, we will provide, free of charge,

parts and service labor in your home to

repair or replace 

any part of the room air

conditioner 

that fails because of a manu-

facturing defect.

FULL FIVE-YEAR WARRANTY

For five years from the date of original

purchase, we will provide, free of charge,

parts and service labor in your home to

repair or replace 

any part of the sealed refrig-

erating system 

(the compressor, condenser,

evaporator and all connecting tubing)

that fails because of a manufacturing

defect.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use

within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you

specific legal rights, and you may also have other rights which vary from state to state. To know what your legal

rights are in your state, consult your local or state consumer affairs office or your state’s Attorney General.

Staple sales slip or cancelled check here. Proof of original purchase 
date is needed to obtain service under warranty.
For service, call 800-GE-CARES.

AIR
CONDITIONER
WARRANTY

What Is Covered

Service trips to your home to teach

you how to use the product.

Improper installation.
If you have an installation problem,

or if the air conditioner is of 

improper cooling capacity for the

intended use, contact your dealer 

or installer. You are responsible for

providing adequate electrical 

connecting facilities.

Replacement of house fuses or reset-

ting of circuit breakers.

In commercial locations labor neces-

sary to move the unit to a location

where it is accessible for service by an

individual technician.

Failure of the product resulting from

modifications to the product or due

to unreasonable use including failure

to provide reasonable and necessary

maintenance.

Failure due to corrosion on models not

corrosion-protected.

Damage to product caused by improp-

er power supply voltage, accident, fire,

floods or acts of God.

Incidental or consequential damage to

personal property caused by possible

defects with this air conditioner.

Warrantor: General Electric Company. Louisville, KY 40225

Summary of Contents for AJCH12DC

Page 1: ...Care of Product 11 Helpful Information Things That Are Normal 12 If Something Goes Wrong Before You Call for Service GE Service Numbers Warranty GE Appliances GE Answer Center 800 626 2000 49 7361 1...

Page 2: ...chase Staple your receipt to the inside back cover of this manual You will need it to obtain service under warranty Start Here Before using your air conditioner Need Help Read this manual It contains...

Page 3: ...oes into the larger slot to provide the proper polarity for the power cord FOR PROPER GROUNDING 1 Screw the adapter to the outlet using the outlet cover screw 2 Ground the outlet through the house wir...

Page 4: ...speeds HIGH HEAT and LOW HEAT provide heating with different fan speeds LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating NOTE If you move the switch from a cool o...

Page 5: ...us up the fan runs all the time The unit is shipped in the CONT setting The vent control is located behind the front grille When set at CLOSE only the air inside the room will be circulated and condit...

Page 6: ...h is not visible from the out side If they are clogged with dirt or soot it will reduce the cooling or heating performance and the unit will not work properly They may be professionally steam cleaned...

Page 7: ...and out On other models pull it down Replace the clean filter by pushing it back into place CAUTION DO NOT operate the air conditioner without the filter in place If a filter becomes torn or damaged i...

Page 8: ...ing may present special problems consult a qualified electrician We recommend that the 230 208 volt 60 Hz models be installed on their own single branch circuit supplying 230 208 volt a c protected wi...

Page 9: ...J Model in an Existing Wall Case 9 J model air conditioners may fit in existing wall cases However they often need a kit to properly adapt the case to the GE air conditioner Answer these questions an...

Page 10: ...that the case installation is secure 4 Reinstall the locking plate with the tab behind the wall case flange Tighten the screw 5 Attach the power cord to the base pan with the clamp 6 When the wall ou...

Page 11: ...ick when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit On the heat pump un...

Page 12: ...flow Set the mode control at HIGH FAN or and stops the air conditioner HIGH COOL with the thermostat from cooling the room at a warmer setting Airflow is restricted Make sure there are no curtains bli...

Page 13: ...Notes 13...

Page 14: ...14 Notes...

Page 15: ...sories sent directly to their home VISA MasterCard and Discover cards are accepted Care and cleaning instructions con tained in this manual cover proce dures to be performed by any user Other servicin...

Page 16: ...To know what your legal rights are in your state consult your local or state consumer affairs office or your state s Attorney General Staple sales slip or cancelled check here Proof of original purcha...

Reviews: