background image

4

49-5000566   Rev. 0

USING THE 

AIR CONDITIONER

Controls

Features and appearance will vary.
Lights beside the touch pads on the air conditioner control panel 
indicate the selected settings.

Remote Control

Air Conditioner Controls

Sleep

Low

Auto

Speed

Mode

WiFi

Med

Cool

High

Fan

F

F

Eco

Filter

1

2

3

4

5

8

7

9

1.   Power Pad

Turns air conditioner on and off. When turned on, the 
display will show the 

Set

 temperature.

2.   Display

Shows the 

Set

 temperature or time remaining on the 

Delay timer. Shows the

 Set 

temperature while setting 

the temperature in 

Cool 

or 

Eco 

modes.

3.   Temp and Delay In /Decrease - Pads

8VHWRVHWWHPSHUDWXUHRUGHOD\WLPH7HPSHUDWXUHFDQ

be set in 

Cool 

and 

Eco 

mode.

4.   Mode Pad

8VHWRVHWWKHDLUFRQGLWLRQHUWR

 Fan Only, Cool, 

or

 

Eco 

mode.

5.   Fan Speed Pad

In

 Cool

 or 

Eco 

PRGH8VHWRVHWWKHIDQVSHHGWR

 

Auto, High, Med 

or

 Low 

on the unit.

In 

Fan Only 

PRGH8VHWRVHWWKHIDQVSHHGWR

 High, 

Med, 

or

 Low 

on the unit.

6.   Delay Pad 

(set by remote control only)

Delay ON—

When the air conditioner is off, it can be 

set to automatically come on in 1 to 24 hours at its 
previous mode and fan settings. 

Delay OFF—

When the air conditioner is on, it can be 

set to automatically turn off in 1 to 24 hours. 

How to set:

Press the 

Delay 

pad on the remote control. Each 

touch of the 

Increase 

/ Decrease 

pads on the 

remote control will set the timer in 1-hour intervals. 

To review the remaining time on the 

Delay 

timer, press 

the 

Delay 

pad on the remote control. Use the

 Increase 

+

 / 

Decrease 

-

 

pads on the remote control to set a new time if 

desired.

To cancel the timer, 

press 

Decrease 

ޕ

 pad on the remote 

control until the set time is zero.

7.   

Sleep Pad 

(set by air conditioner controls only)

The 

SLEEP

 mode sets the unit to gradually change 

settings over an 8 hour period to allow for some 
increased energy efficiency during sleep hours.
The 

SLEEP

 mode is available only in 

COOL

 and 

FAN

 only settings.

Press the 

SLEEP

 mode pad and its light will 

illuminate. The fan indicator will stay at the same 
setting but the air conditioner will automatically 
change the 

FAN

 speed to low in either 

COOL

 or 

FAN

 only mode.

In 

FAN

 only mode, the fan will stay in the 

LOW

 

speed setting for 8 hours. After 8 hours, the air 
conditioner will resume the settings that were in 
place before the 

SLEEP

 mode pad was pressed.

In 

COOL

 mode, the fan will stay in the 

LOW

 speed 

setting for 8 hours from the time the 

SLEEP

 mode 

pad was pressed. The air conditioner will also 
raise the set point 2

°

F in 30 minutes and 2

°

F more 

in another 30 minutes where it will remain for the 

QH[WKRXUV$IWHUKRXUVWKHDLUFRQGLWLRQHUZLOO

resume the settings that were in place before the 

SLEEP

 mode pad was pressed.

While the unit is in 

SLEEP

 mode, pressing any pad 

will return it to the settings that were in place before 
the 

SLEEP

 mode pad was pressed.

8.   

Filter Reset Pad

This feature automatically notifies you that the air filter 
must be cleaned. The indicator light will come on after 
250 hours of operation. Clean the air filter (refer to 

SDJHSODFHLWEDFNLQWKHIURQWSDQHODQGSUHVVWKH

Filter Reset

 pad. The light will go off.

 

9.   WiFi Connect Pad

Enables connection of the air conditioner to the 
home WiFi. Download App for details at:

www.GEAppliances.com/connect

.

Solid light indicates WiFi 
connected
Blinking light indicates 
connecting
See Appliance Communication 
section in this manual

Power

Speed

Mode

Eco

Delay

1

4

5

6

3

Summary of Contents for AHTK18AAH1

Page 1: ...NFORMATION 3 USING THE AIR CONDITIONER Controls 4 Remote Control 5 Cool Mode 5 Energy Saver Mode 5 Air Direction 6 CARE AND CLEANING Grille and Case 6 Air Filter 6 Outdoor Coils 6 Install Batteries in...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...ndow Air Conditioner HOW TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO...

Page 4: ...e control until the set time is zero 7 Sleep Pad set by air conditioner controls only The SLEEP mode sets the unit to gradually change settings over an 8 hour period to allow for some increased energy...

Page 5: ...High or Med fan with a middle set temperature For Maximum Cooling Select the Cool mode and High fan with a lower set temperature For Quieter and Nighttime Cooling Select the Cool mode and Low fan wit...

Page 6: ...r Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce per...

Page 7: ...ding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong...

Page 8: ...l Top Mounting Rail may be installed already Foam Seal UDFNHW Screws 6 RRG Screws 8 ODW HDG ROW DQG Lock Nut 2 A B C D DELAY MODE ON OFF SPEED TEMP TIME TEMP TIME PARTS INCLUDED Appearance may vary Si...

Page 9: ...pes of windows The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm w...

Page 10: ...mounting rail if not already installed with four type A screws B Slide left hand curtain assembly into left end of top and bottom mounting rail Repeat for right hand curtain assembly C Fasten curtain...

Page 11: ...WKUHH W SH VFUHZV WR VHFXUH WKH FDVH WR the window sill Drill pilot holes if necessary Bottom rail Top rail Window sash SILL About RRG 6FUHZV RRG Screws 6 INSTALL OUTER CASE IN WINDOW D Thread nut ont...

Page 12: ...pe C screw to secure the window in place A B A Top of lower window sash B Foam seal Vinyl Wood 8 RETURN CHASSIS TO THE OUTER CASE A Once the case is securely attached to the window reinstall the air c...

Page 13: ...e there are not curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set properly Turn the temperature control to a higher number The air filter is dirty...

Page 14: ...RSHUO LQVHUWHG This plug may be removed during operation to minimize water in the back of the unit however removing it will lower the efficiency of your unit NOTE Do not drill hole in the base pan Bas...

Page 15: ...s been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfere...

Page 16: ...16 49 5000566 Rev 0 Notes NOTES...

Page 17: ...t Cover 7KLV OLPLWHG ZDUUDQW LV H WHQGHG WR WKH RULJLQDO SXUFKDVHU DQG DQ VXFFHHGLQJ RZQHU IRU SURGXFWV SXUFKDVHG IRU KRPH XVH ZLWKLQ WKH 86 I WKH SURGXFW LV ORFDWHG LQ DQ DUHD ZKHUH VHUYLFH E D SSOLF...

Page 18: ...LOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty or call 800 62...

Page 19: ...na 9 Preparaci n del Acondicionador de Aire 10 Instalaci n del Acondicionador de Aire 12 CONSEJOS PARA LA SOLUCI N DE PROBLEMAS 13 Sonidos de Funcionamiento Normal 14 CONFIGURACI N WIFI 14 SOPORTE AL...

Page 20: ...y creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Regis...

Page 21: ...JXQD FLUFXQVWDQFLD FRUWH R HOLPLQH HO WHUFHU FDEOH WLHUUD GHO FDEOH GH FRUULHQWH 3DUD VX VHJXULGDG SHUVRQDO HVWH electrodom stico debe estar adecuadamente conectado a tierra NO use un enchufe adaptado...

Page 22: ...raso de control UHPRWR 8VH ODV WHFODV Increase Incrementar Decrease Reducir de control remoto para configurar un tiempo nuevo si as lo desea Para cancelar el temporizador presione la tecla reducir en...

Page 23: ...tura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo Cool Fr o y ventilador Low Bajo con una temperatura de ajuste media Eco Modo de ahorro de energ a Controla...

Page 24: ...con agua caliente y jab n Enjuague y deje VHFDU HO ILOWUR DQWHV GH VX UHHPSOD R 1R OLPSLH HO ILOWUR HQ XQ lavavajillas PRECAUCI N 12 XWLOLFH HO DFRQGLFLRQDGRU GH aire sin un filtro ya que la suciedad...

Page 25: ...tamente conectado a tierra OJXQRV PRGHORV UHTXLHUHQ YROWLRV GH corriente alterna protegidos por un fusible de dilataci n de tiempo o un cortacircuitos Estos modelos deber an instalarse en un ramal exc...

Page 26: ...Riel de Montaje Superior HV SRVLEOH TXH D HVWp LQVWDODGR Sellador de Gomaespuma Tornillos de Soporte de Tornillos de Madera de Tornillo de Cabeza Plana de RQWUDWXHUFD A C PARTES INCLUIDAS La aparienc...

Page 27: ...coloque un SHGD R GH PDGHUD HQ HO XPEUDO SDUD KDFHUOD m s alta que la parte superior del marco de la ventana de tormentas o del marco vinilo P guelo firmemente con clavos o con tornillos proporcionad...

Page 28: ...el extremo izquierdo del riel de montaje superior e inferior Repita este proceso en la junta de la cortina del lado derecho C Ajuste las tiras de retenci n de la cortina a los costados de la caja ext...

Page 29: ...ga agujeros piloto Bottom rail Top rail Window sash SILL About 5 7RUQLOORV GH 0DGHUD GH Tornillos de 0DGHUD GH 6 INSTALE LA CAJA EXTERNA EN LA VENTANA D Enrosque la tuerca en el tornillo luego enrosqu...

Page 30: ...H TXH OD FDMD HVWp DGKHULGD GH IRUPD VHJXUD a la ventana vuelva a instalar el acondicionador de DLUH RV SHUVRQDV GHEHQ OHYDQWDU HO DFRQGLFLRQDGRU de aire y deslizar el mismo sobre la caja Aseg rese de...

Page 31: ...El flujo de aire est restringido Cerci rese de que no existe ninguna cortina persiana o mueble bloqueando el frente del acondicionador de aire El control de temperatura no est ajustado apropiadamente...

Page 32: ...sin embargo quitarlo reducir la eficiencia de su unidad NOTA 1R KDJD XQ DJXMHUR HQ OD ROOD GH OD EDVH enchufe basepan Configuraci n WiFi GE Appliances WiFi Connect Conexi n WiFi de GE Appliances Para...

Page 33: ...e al comerciante minorista o a un t cnico experimentado de radio televisi n Etiqueta Las modificaciones sobre esta unidad no aprobadas expresamente por parte del fabricante podr an anular la autoridad...

Page 34: ...49 5000566 Rev 0 Notas NOTAS...

Page 35: ...pV GH OD HQWUHJD Qu No Cubrir GE Appliances Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso UHVLGHQFLDO GHQWUR GH VWDGRV 8QLGRV 6L HO SU...

Page 36: ...ibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los Servicios de GE Appliances a n HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEAppliances com...

Reviews: