background image

Write the model and serial 
numbers here:

Model # _________________

Serial # _________________

You can find the rating label on the 
side of the air conditioner.

GE is a trademark of the General Electric Company. Manufactured under trademark license.

OWNER’S MANUAL

AIR CONDITIONER

ROOM

49-5000719   Rev. 1   10-22   GEA

SAFETY INFORMATION

  . . . . . . . . .3

USING THE AIR CONDITIONER

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Remote Control  . . . . . . . . . . . . . . . . . . . . . . .6
Cool Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Eco    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Air Direction . . . . . . . . . . . . . . . . . . . . . . . . . .7

CARE AND CLEANING

Grille and Case . . . . . . . . . . . . . . . . . . . . . . . .8
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Outdoor Coils . . . . . . . . . . . . . . . . . . . . . . . . .8
Install Batteries in Remote . . . . . . . . . . . . . .8

INSTALLATION INSTRUCTIONS

Before you begin . . . . . . . . . . . . . . . . . . . . . .9
Electrical Requirements  . . . . . . . . . . . . . . . .9
Parts Included . . . . . . . . . . . . . . . . . . . . . . . . 10
Window Requirements  . . . . . . . . . . . . . . . . 11
Prepare the Air Conditioner . . . . . . . . . . . . 11
Install the Air Conditioner . . . . . . . . . . . . . . 12

TROUBLESHOOTING TIPS

 . . . . . . 14

Normal Operating Sounds  . . . . . . . . . . . . . 15

CONSUMER SUPPORT

Limited Warranty . . . . . . . . . . . . . . . . . . . . . 17
Consumer Support . . . . . . . . . . . . . . . . . . . . 18

AHLE06CA

ENGLISH/ESPAÑOL

Summary of Contents for AHLE06CA

Page 1: ...FETY INFORMATION 3 USING THE AIR CONDITIONER Controls 5 Remote Control 6 Cool Mode 6 Eco 6 Air Direction 7 CARE AND CLEANING Grille and Case 8 Air Filter 8 Outdoor Coils 8 Install Batteries in Remote 8 INSTALLATION INSTRUCTIONS Before you begin 9 Electrical Requirements 9 Parts Included 10 Window Requirements 11 Prepare the Air Conditioner 11 Install the Air Conditioner 12 TROUBLESHOOTING TIPS 14 ...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...r liquids in the vicinity of this or any other appliance Ŷ If the receptacle does not match the plug the receptacle must be changed out by a qualified electrician Ŷ R QRW XVH PHDQV WR DFFHOHUDWH WKH GHIURVWLQJ SURFHVV or to clean other than those recommended by the manufacturer Ŷ The appliance shall be stored in a room without continuously operating ignition sources for example open flames an oper...

Page 4: ...c basis by first pressing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded Where a 2 prong wall outlet i...

Page 5: ...to 24 hours How to set Press the Delay 1 24hr pad on the unit or the remote control Each touch of the Increase Decrease pads on the unit or the remote control will set the timer in 1 hour intervals To review the remaining time on the Delay 1 24hr timer press the Delay 1 24hr pad on the unit or the UHPRWH FRQWURO 8VH WKH Increase Decrease pads on the unit or on the remote control to set a new time ...

Page 6: ... Set the thermostat at a higher number and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the Cool mode and High or Med fan with a middle set temp...

Page 7: ...to automatically set to the speed needed to provide optimum comfort settings with the set temperature If the room needs more cooling the fan speed will automatically increase If the room needs less cooling the fan speed will automatically decrease Air Direction 8VH WKH OHYHU WR DGMXVW WKH DLU GLUHFWLRQ OHIW WR ULJKW ...

Page 8: ...e air conditioner without a filter because dirt and lint will clog it and reduce performance Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned How to Insert the Batteries in the Remote Control 1 Remove the battery cover by sliding it according to the arrow direction 2 Insert new ba...

Page 9: ... models require a 115 120 volt AC 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet CAUTION Do not under any circumstances cut or remove the...

Page 10: ...de Curtain Frame Type B 9 RRG Screws Foam top window gasket Side Curtain 2 Top mounting rail Air conditioner Window locking bracket 1 Side Brackets 2 PARTS INCLUDED Appearance may vary Remote Control Left Right Type A 3 DELAY MODE ON OFF SPEED TEMP TIME TEMP TIME Power Speed Mode Eco Delay ...

Page 11: ...l supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model 2 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will NHHS LW IURP GUDLQLQJ SURSHUO 7R DGMXVW IRU WKLV attach a piece of wood to the sill WOO...

Page 12: ...indow so that is it centered Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill B Bring the window down so that the front edge of the top mounting is in front of the window Make sure that the air conditioner is level or tilting slightly to the outside C Extend the curtain panels until they fill the window Mark the location of the holes in ...

Page 13: ...or damage to windows on vinyl or other similarly constructed windows attach the window locking bracket to the ZLQGRZ VLGH MDPE ZLWK RQH Type B screw B Cut the foam top window gasket to the window width C Stuff the foam between the glass and the window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to pr...

Page 14: ...ot cool as it should Indoor airflow is restricted Make sure there are not curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set properly Turn the temperature control to a higher number The air filter is dirty Clean the filter at least every 30 days See Care and Cleaning section The room may have been hot When the air conditioner is first turned on y...

Page 15: ...H outdoor side of the unit Ŷ 7KH IDQ PD UXQ HYHQ ZKHQ WKH FRPSUHVVRU GRHV QRW Ŷ DWHU GURSOHWV EHLQJ WKURZQ DJDLQVW WKH RXWVLGH FRLOV FDQ PDNH D SLQJLQJ QRLVH 7KLV KHOSV FRRO WKH FRQGHQVHU You can reduce this noise by removing the subbase water plug To ensure maximum efficiency it is recommended to check to ensure the rubber drain plug is properly inserted This plug may be removed during operation ...

Page 16: ...16 49 5000719 Rev 1 Notes NOTES ...

Page 17: ...r providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Replacement of house fuses or resetting of circuit breakers Failure due to corrosion Damage to the product caused by improper power supply voltage accident fire floods or acts of God Inc...

Page 18: ...DWHULDO Q WKH 86 GEAppliances com register Parts and Accessories Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day Q WKH 86 GEApplianceparts com or by phone at 877 959 8688 during normal business hours Instructions contained in this manual cover proc...

Page 19: ...cluidas 8 Requisitos de la Ventana 9 Preparación del Acondicionador de Aire 9 Instalación del Acondicionador de Aire 10 CONSEJOS PARA LA SOLUCIÓN DE PROBLEMAS 14 Sonidos de Funcionamiento Normal 15 SOPORTE AL CLIENTE Garantía Limitada 17 Soporte al Cliente 18 GE es una marca registrada de General Electric Company Fabricado bajo licencia de marca MANUAL DEL PROPIETARIO Escriba los números de modelo...

Page 20: ...s y creemos que usted también Entre otras cosas el registro de su electrodoméstico asegura que podamos entregarle información importante del producto y detalles de la garantía cuando los necesite Registre su electrodoméstico GE ahora a través de Internet Sitios Web y números telefónicos útiles están disponibles en la sección de Soporte para el Consumidor de este Manual del Propietario También pued...

Page 21: ...ectrodoméstico Ŷ 6L HO UHFHSWiFXOR QR FRLQFLGH FRQ HO HQFKXIH HO FDPELR GHO mismo deberá ser realizado por un electricista calificado ADVERTENCIA Ŷ ILQ GH DFHOHUDU HO SURFHVR GH GHVFRQJHODFLyQ R para limpiar no use ningún método que no sea el recomendado por el fabricante Ŷ VWH HOHFWURGRPpVWLFR GHEHUi VHU JXDUGDGR HQ XQD sala donde no haya fuentes de encendido continuas SRU HMHPSOR OODPDV DELHUWDV...

Page 22: ...botón de evaluación y reinicio en la caja del enchufe El dispositivo deberá ser evaluado en forma periódica presionando primero el botón TEST YDOXDU OXHJR RESET 5HLQLFLR mientras se encuentre enchufado al tomacorriente Si el botón TEST YDOXDU QR VH DFWLYD R HO ERWyQ RESET 5HLQLFLR QR permanece en su posición deje de usar el acondicionador de aire y comuníquese con un técnico calificado del servici...

Page 23: ...e encendido se podrá configurar automáticamente para que se apague en un período de entre 1 y 24 horas Cómo configurar Presione la tecla Delay 1 24hr 5HWUDVR HQWUH KUV en la unidad o en el control remoto Cada vez que presione las teclas Increase Incrementar Decrease Reducir de la unidad del control remoto se ajustará el temporizador por intervalos de 1 hora Para revisar el tiempo restante en el te...

Page 24: ...pagado y luego se enciende mientras se ajusta en la configuración Cool UtR R VL VH SDVD GH XQD FRQILJXUDFLyQ GH YHQWLODFLyQ D XQD FRQILJXUDFLyQ GH RRO UtR HV SRVLEOH TXH DO FRPSUHVRU OH tome aproximadamente 3 minutos comenzar y que comience la refrigeración Descripciones de enfriamiento Para enfriamiento normal Seleccione el modo Cool Frío y ventilador High Alto o Med Medio con una temperatura de ...

Page 25: ...a en la velocidad necesaria para brindar ajustes de confort óptimos con la temperatura configurada Si se necesita más frío en la habitación la velocidad del ventilador se incrementará de forma automática Si se necesita más frío en la habitación la velocidad del ventilador se reducirá de forma automática Dirección del Aire 8VH OD SDODQFD SDUD DMXVWDU OD GLUHFFLyQ GHO DLUH KDFLD OD izquierda o la de...

Page 26: ...sin un filtro ya que la suciedad y las pelusas producirán atascamientos y reducirán su funcionamiento Bobinas Exteriores Las bobinas del lado exterior del acondicionador de aire se deberán controlar de forma regular Si se encuentran atascadas con tierra u hollín deberán ser limpiadas por un profesional CUIDADO Y LIMPIEZA Cómo insertar las pilas en el control remoto 1 Retire la cubierta de la pila ...

Page 27: ...con un fusible de dilatación de tiempo de 15 amperios o un cortacircuitos El enchufe de tres púas con conexión a tierra minimiza la posibilidad de descargas eléctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad hacer que un técnico lo reemplace por uno de tres tomas con conexión a tierra PRECAUCIÓN DMR QLQJXQD FLUFXQVWDQFLD FRUWH R UHPXHYD O...

Page 28: ...uma de la parte superior de la ventana Cortinas Laterales Riel de montaje superior Acondicionador de aire Soporte de Cierre GH OD 9HQWDQD Soportes Laterales PARTES INCLUIDAS La apariencia puede variar Control Remoto 7LSR Marcos de la Cortina Lateral dejado derecho DELAY MODE ON OFF SPEED TEMP TIME TEMP TIME Power Speed Mode Eco Delay ...

Page 29: ...e aseguradas a algún metal mampostería o a la madera El tomacorriente eléctrico debe estar al alcance del cable eléctrico del acondicionador de aire Siga las dimensiones de la tabla y la ilustración según su modelo 2 REQUISITOS DE UNA VENTANA DE TORMENTAS 8Q PDUFR GH YHQWDQD GH WRUPHQWDV QR SHUPLWLUi TXH el acondicionador de aire se incline hacia el exterior y evitará que drene apropiadamente Para...

Page 30: ...re de modo que el extremo frontal del riel de montaje inferior se encuentre contra el extremo trasero del alféizar B DMH OD YHQWDQD GH PRGR TXH HO H WUHPR IURQWDO GHO montaje superior se encuentre delante de la ventana Asegúrese de que el acondicionador de aire esté nivelado o apenas inclinado hacia el exterior C Extienda los paneles de la cortina hasta que llenen la ventana Marque la ubicación de...

Page 31: ...bre las ventanas sobre vinilo o ventanas construidas de manera similar adjunte el soporte de bloqueo de la ventana a la jamba lateral de la ventana con un tornillo 7LSR B Corte la junta de gomaespuma superior de la ventana del mismo ancho que la ventana C Coloque la gomaespuma entre el vidrio y la ventana para evitar el ingreso de aire e insectos a la habitación NOTA Si la junta provista no se aju...

Page 32: ...estringido Cerciórese de que no existe ninguna cortina persiana o mueble bloqueando el frente del acondicionador de aire El control de temperatura no está ajustado apropiadamente En los modelos con botones gire la temperatura a un número mayor El filtro de aire está sucio Limpie el filtro cada 30 días por lo menos Ver la sección de Cuidado y limpieza La habitación podría haber estado caliente Cuan...

Page 33: ...d Ŷ O YHQWLODGRU SRGUtD IXQFLRQDU DXQ VL HO FRPSUHVRU QR OR KDFH Ŷ DV JRWLWDV GH DJXD TXH FDHQ FRQWUD ODV ERELQDV H WHUQDV SXHGHQ KDFHU XQ UXLGR GH SLQJ VWR D XGD D HQIULDU HO FRQGHQVDGRU 3XHGH UHGXFLU HVWH UXLGR UHWLUDQGR HO HQFKXIH GH DJXD GH OD VXE EDVH Para asegurar la máxima eficiencia se recomienda verificar que el tapón de drenaje de goma esté correctamente insertado Este tapón se puede qui...

Page 34: ...16 49 5000719 Rev 1 Notas NOTAS ...

Page 35: ...l producto no posee la capacidad adecuada contacte a su vendedor minorista o instalador Usted es responsable de brindar instalaciones de conexión eléctrica adecuadas Ŷ DOOD GHO SURGXFWR FRPR UHVXOWDGR GH PRGLILFDFLRQHV VREUH el mismo o debido a un uso irrazonable incluyendo la falta de mantenimiento razonable o necesario Ŷ 5HHPSOD R GH IXVLEOHV GHO KRJDU R UHLQLFLR GH GLV XQWRUHV Ŷ DOODV FRPR FRQV...

Page 36: ...ances com register Piezas y Accesorios Aquellos individuos calificados para realizar el servicio técnico de sus propios electrodomésticos podrán solicitar el envío de SLH DV R DFFHVRULRV GLUHFWDPHQWH D VXV KRJDUHV VH DFHSWDQ ODV WDUMHWDV 9 6 0DVWHU DUG LVFRYHU 2UGHQH KR D WUDYpV GH QWHUQHW GXUDQWH ODV KRUDV WRGRV ORV GtDV Q 88 GEApplianceparts com o de forma telefónica al 877 959 8688 durante el h...