background image

 Dehumidifier

How it 

Moist, humid air is drawn over a
cold, refrigerated dehumidifying
coil. Moisture in the air condenses
on this coil and then drains into a
bucket (or through a hose into a

drain). Dry, clean air is then drawn
over the condenser where it is
actually heated several degrees and
discharged out the front grille into
the room. It is normal for the
surrounding air to become slightly
warmer as the dehumidifier
operates. This warming effect
further reduces the relative

humidity of the surrounding air.

Refrigeration
Unit 

-

SIDE VIEW

When locating the dehumidifier,
be sure to place it where there is no
restriction to the air flow either into
the coil at the rear or from the front
grille. Good air circulation through
the appliance is essential to efficient
operation.

Humidity Control

A Humidity Control, built into
your dehumidifier, automatically
maintains a selected humidity level.
It starts the dehumidifier when the
humidity is high and shuts it off
when the humidity is low.

 

3

2

FULL

OFF

CONTINUOUS

HUMIDITY CONTROL

For 
dehumidification

The Humidity Control has settings
from “l” to 

 Turning the

control knob to “10” provides the
greatest amount of dehumidification,
turning it to “l” provides the least.

Even when the Humidity Control is
set at 

 the dehumidifier will

run continuously during particularly
humid periods due to seepage of
humid air into the room through

the 

 around doors and windows

and through the use of clothes dryers
and similar equipment that add
moisture to the air. The continuous
operation of the dehumidifier during
such humid periods is normal and
necessary to maintain desired

conditions.

The 

 3 or 4 days that you have

your dehumidifier, run it at “10”
to allow it to remove large amounts
of accumulated moisture from the
room. When the room has reached
the desired humidity level, the
amount of moisture removed from
the air will be considerably less.
Rotate the Humidity Control knob

toward “l” until the dehumidifier

shuts off. The Humidity Control
will automatically maintain the

desired dryness in the room.

When the dehumidifier is 
turned on 
and the dehumidifying
coil is dry, a light coating of frost
will appear. This is normal. The
frost will usually disappear in 30 to

45 minutes.

If room temperature goes below

 frost may accumulate on the

dehumidifying coil, reducing the
unit’s operating efficiency. On Auto
Defrost models, the compressor
will shut off automatically until the
coil reaches the correct operating

temperature. The fan will continue
to run to aid in the defrosting. For
models without the Auto Defrost
feature, we recommend that you
turn the Humidity Control knob to

“l” to allow the coil to defrost.

Then turn it back to your desired
setting.

The Auto Defrost feature is also
designed to prevent excessive on-off
cycling, and under certain conditions
may allow the frost to remain on
the coil for some time before the
compressor shuts off and the frost
is cleared. This is not unusual.

4

Summary of Contents for AHD15

Page 1: ...ce 7 Auto Defrost 4 Safety Instructions 2 Care and Cleaning 5 User Maintenance Instructions 5 Condenser Coils 6 Warrantv Back Cover Control Settings 4 5 Water Overflow Control 5 Electrical Requirements 3 Extension Cords 3 Grille and Cabinet 6 Grounding 3 GEAmwer CenteP Humidity Control 4 5 8W U62W Models AHD15 AHD24 AHD38 GE Qual Pmduti ...

Page 2: ...t sold you the dehumidifier Save time and money Before you request service Check the Problem Solver on page 7 It lists causes of minor operating problems that you can correct yourself hportant Safety Imtrudiom Read W instruction before us this apphnce When using this appliance always exercise basic safety precautions including the following Use thk appliance only for its intended purpose as descri...

Page 3: ... UL listed adapter Fig 2 available at most local hardware stores TEMPORARY METHOD PERMITTEOINCANADA AOAPTER PLUGS NOT P I ON Fig 2 BEFORE USE The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord ON Attaching an adapter ground terminal to all outlet cover screw does not ground appliance unless cover scr...

Page 4: ... the room through the tis around doors and windows and through the use of clothes dryers and similar equipment that add moisture to the air The continuous operation of the dehumidifier during such humid periods is normal and necessary to maintain desired conditions The first 3 or 4 days that you have your dehumidifier run it at 10 to allow it to remove large amounts of accumulated moisture from th...

Page 5: ...ket overflows Before removing the bucket move the control cord attached to the float to the OFF up position This will keep the float up and prevent the dehumidifier from operating when the bucket is not in place k H M ve Cord to OFF Full of Water t m I L Afier replacing the bucket move the control cord to the ON down position and make sure the float hangs freely inside the bucket For continuom dra...

Page 6: ...S SHOULD three or four days with the Humidity Control knob set at 10 maybe quired to achieve and maintain the desired dryness o obj fi bloc ng front d or back ofdehu difi r will restrict air flOW md reduce efficiency Hu Control maybe Wt too 10W Turn control knob to a higher setting Doom and or windows may not be tightiy closed o Clothes d er may b blming moisture laden air into the room WATER ON F...

Page 7: ...urther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations GE Appliances Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel 20...

Page 8: ...ges of your telephone directory for GENERAL ELECTRIC COMPANY GENERAL ELECTRIC FA RY SERVICE GENERAL ELECTRIC H POINT FA RY SERVICE or GENERAL ELECTRIC CU MER CARE SERVICE WHAT IS N COVERED Service trips to your home to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office...

Reviews: