Summary of Contents for AGX10

Page 1: ...Find these numbers on a label on the side of the air conditioner Safety Instructions 2 3 Operating Instructions 4 5 Care and Cleaning Air Filter 6 Grille and Case 6 Outdoor Coils 6 Installation Instru...

Page 2: ...uirements HOW TO CONNECT ELECTRICITY 2 Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION READ AL...

Page 3: ...g wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in...

Page 4: ...cooling NOTE If you move the switch from a cool setting to OFF or to a fan setting wait at least 3 minutes before switching back to a cool setting Cooling Descriptions For Normal Cooling Select HIGH C...

Page 5: ...rge grille When set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside Air Direction The side to side air direction levers a...

Page 6: ...fore replacing it Replace the filter and close the inlet grille CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance 4 3 2 1 Outdoor Co...

Page 7: ...c basis by first pressing the TEST button and then the RESET button If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a q...

Page 8: ...Care and Cleaning Operating Instructions Safety Instructions 8 Filler panel frame Filler panel Side guide 2 Leveling bolt and nut Support angle Support platform Air conditioner Type A 2 Washer 2 and N...

Page 9: ...Cord Exit You may change the power cord exit from the bottom to the side if desired for appearance or window sill clearance Grasp both sides of the inlet grille and pull forward The inlet grille will...

Page 10: ...place a piece of wood between the stool and the support platform to make it 1 16 higher than the top of the window track Attach securely with nails or screws provided by the installer Measure and mark...

Page 11: ...Measure the height of the window opening from the top of the support platform Subtract 203 4 inches Mark this measurement on the filler panel and cut it evenly across Insert the uncut end of the fill...

Page 12: ...s NOTE Check all seals and plug any remaining air gaps with a suitable weatherproof caulk C B A 8 Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructio...

Page 13: ...urely NOTE If you removed the catch handle and crank handle assembly fill the holes with caulk to protect against weather NOTE Window molding may need to be modified for proper installation C B A 1 Sa...

Page 14: ...linds or furniture not cool as it should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum coo...

Page 15: ...the product caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this air conditioner Damage caused after deli...

Page 16: ...al discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be the...

Reviews: