background image

Safety Instructions

Operating Instructions

Care and Cleaning

Installation Instructions

Tr

oubleshooting T

ips

Consumer Support

Preparing to install the air conditioner.

Read these instructions completely and carefully.

NOTE TO INSTALLER:

Leave these instructions

with the air conditioner after installation is
completed.

NOTE TO CONSUMER: 

Keep Owner’s Manual

and Installation Instructions for future use.

CAUTION:

Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.

Do not change the plug on the power cord of
this air conditioner.

Aluminum house wiring may present special
problems—consult a qualified electrician.

IMPORTANT NOTES:

For personal safety, this air conditioner must be
properly grounded.

It is important to have the wall outlet and circuit
checked by a qualified electrician if there is any
doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or
local codes and ordinances.

Power cord includes a current interrupter
device. A test and reset button is provided on
the plug case. The device should be tested on a
periodic basis by first pressing the 

TEST

button

and then the 

RESET

button. If the 

TEST

button

does not trip or if the 

RESET

button will not stay

engaged, discontinue use of the air conditioner
and contact a qualified service technician.

Before You Begin

Some models require 115/120-volt a.c.,
60 Hz grounded outlet protected with
a 15-amp time delay fuse or circuit
breaker.

The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet, 
it is your responsibility to have it replaced with 
a properly grounded 3-prong wall outlet.

Some models require 230/208-volt 
a.c., protected with a time delay fuse 
or circuit breaker. These models 
should be installed on their own single
branch circuit for best performance 
and to prevent overloading house 
or apartment wiring circuits, which 
could cause a possible fire hazard 
from overheating wires.

Electrical Requirements

■ 

Screwdrivers

■ 

Ruler or tape measure

■ 

Scissors or knife

■ 

Pencil

■ 

Level

■ 

Drill and 1/8

bit

Tools You Will Need

Open the inlet grille and remove the filter.
See the 

Air Filter

section.

Secure the front grille frame with the two
screws packed with the Owner’s Manual.

Replace the filter and close the inlet grille.

C

B

A

Before Installing the Air Conditioner

Inlet grille

7

Summary of Contents for AGX10

Page 1: ...Find these numbers on a label on the side of the air conditioner Safety Instructions 2 3 Operating Instructions 4 5 Care and Cleaning Air Filter 6 Grille and Case 6 Outdoor Coils 6 Installation Instru...

Page 2: ...uirements HOW TO CONNECT ELECTRICITY 2 Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION READ AL...

Page 3: ...g wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in...

Page 4: ...cooling NOTE If you move the switch from a cool setting to OFF or to a fan setting wait at least 3 minutes before switching back to a cool setting Cooling Descriptions For Normal Cooling Select HIGH C...

Page 5: ...rge grille When set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside Air Direction The side to side air direction levers a...

Page 6: ...fore replacing it Replace the filter and close the inlet grille CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance 4 3 2 1 Outdoor Co...

Page 7: ...c basis by first pressing the TEST button and then the RESET button If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a q...

Page 8: ...Care and Cleaning Operating Instructions Safety Instructions 8 Filler panel frame Filler panel Side guide 2 Leveling bolt and nut Support angle Support platform Air conditioner Type A 2 Washer 2 and N...

Page 9: ...Cord Exit You may change the power cord exit from the bottom to the side if desired for appearance or window sill clearance Grasp both sides of the inlet grille and pull forward The inlet grille will...

Page 10: ...place a piece of wood between the stool and the support platform to make it 1 16 higher than the top of the window track Attach securely with nails or screws provided by the installer Measure and mark...

Page 11: ...Measure the height of the window opening from the top of the support platform Subtract 203 4 inches Mark this measurement on the filler panel and cut it evenly across Insert the uncut end of the fill...

Page 12: ...s NOTE Check all seals and plug any remaining air gaps with a suitable weatherproof caulk C B A 8 Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructio...

Page 13: ...urely NOTE If you removed the catch handle and crank handle assembly fill the holes with caulk to protect against weather NOTE Window molding may need to be modified for proper installation C B A 1 Sa...

Page 14: ...linds or furniture not cool as it should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum coo...

Page 15: ...the product caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this air conditioner Damage caused after deli...

Page 16: ...al discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be the...

Reviews: