background image

AGM06
AGM08

AGQ08

AGV08

AGM10

AGQ10

AGV10

AGM12

AGQ12

AGV12

AGQ14

AGV14

Safety Instructions

 . . . . . . . .2, 3

Operating Instructions

Control Knob Models  . . . . . .6, 7
Touch Pad Models . . . . . . . . .4, 5

Care and Cleaning

Air Filter  . . . . . . . . . . . . . . . . . .8
Grille and Case  . . . . . . . . . . . . .8
Outdoor Coils  . . . . . . . . . . . . . .8

Installation Instructions

Preparing to Install the
Air Conditioner  . . . . . . . . . . . . .9
Window Installation  . . . . . .10–14

Troubleshooting Tips

 . . . . . .15

Normal Operating Sounds  . . .16

Consumer Support

Consumer Support  . . . . . . . . .20
Product Registration  . . . . .17, 18
Warranty  . . . . . . . . . . . . . . . . .19

3828A21031E

49-7521    11-05 JR   

Owner’s Manual and

Installation Instructions

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the
side of the air conditioner.

A

ir Condit

io

ners

Room

ge.com

Summary of Contents for AGM06

Page 1: ...ng to Install the Air Conditioner 9 Window Installation 10 14 Troubleshooting Tips 15 Normal Operating Sounds 16 Consumer Support Consumer Support 20 Product Registration 17 18 Warranty 19 3828A21031E 49 7521 11 05 JR Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a label ...

Page 2: ... disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazard from this appliance...

Page 3: ...perly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug with the othe...

Page 4: ...ll continue to run for a short time after the compressor cycles off OFF The fan runs all the time while the compressor cycles on and off This feature must be set at OFF in order to use the fan settings on the mode control NOTE On some models the ENERGY SAVER feature cannot be set on the air conditioner It must be set using the remote control CIRCULAIRE on some models For continuous side to side ai...

Page 5: ...ode and LOW F1 fan with a middle set temperature NOTE If you switch from a COOL setting to OFF or to a fan setting wait at least 3 minutes before switching back to a COOL setting FAN Mode Use the FAN at HIGH F3 MED F2 or LOW F1 to provide air circulation and filtering without cooling Since fan only settings do not provide cooling a temperature setting will not be displayed Consumer Support Trouble...

Page 6: ...t number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the indoor air will become cooler Turn the knob to a lower number and the indoor air will b...

Page 7: ...IRCULAIRE on some models For fixed side to side air direction set the Circulaire switch to ON until the desired air direction is obtained then move it to OFF For continuous side to side air circulation cool settings only set the Circulaire switch to ON Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results in wider vari...

Page 8: ...perate the air conditioner without a filter because dirt and lint will clog it and reduce performance 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water and a...

Page 9: ... 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard from overhea...

Page 10: ...acket Frame guide 2 Top mounting rail Top mounting rail seal strip Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 3 Type C 5 Bolt 2 Nut 2 PARTS INCLUDED Appearance may vary 10 Installation Instructions ...

Page 11: ...8 000 and 10 000 BTU models See last illustration for AGM10 dimensions AGM10 12 000 and 14 000 BTU models 24 min Without accordion panels 16 min 27 to 39 With accordion panels STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 ...

Page 12: ...ide Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail Install the top mounting rail with 3 type A screws on the inside of the case Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordion panels to the side of the case using 4 type A screws on each side D C B 4 Installation Instructio...

Page 13: ...int on the sill Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support E D C B A 5 Installation Instructions Bolt Nut Sill support OUTDOOR INDOOR Frame guide INSTALL THE CASE IN THE WINDOW CONT Adjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside Use a level about 1 3 bubble w...

Page 14: ...t of the case Push the grille in until it snaps into place Lift the inlet grille and secure the front frame with a type A screw through the front grille Lower the inlet grille back into place D C B A Installation Instructions INSTALL A SUPPORT BRACKET AND THE FOAM TOP WINDOW GASKET Attach a support bracket with a Type C screw Cut the foam top window gasket to the window width Stuff the foam betwee...

Page 15: ...u need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the air flow and On models with control knobs set the mode control at freezing up stops the air conditioner HIGH FAN or HIGH C...

Page 16: ...cked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit The fan may run even when the compressor...

Page 17: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Page 18: ...ut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Read your Owner s Manual carefully It...

Page 19: ...duct caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this air conditioner Damage caused after delivery Product not accessible to provide required service What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If ...

Page 20: ...ut special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and...

Page 21: ...r de aire 9 Solucionar problemas 15 16 Sonidos normales de operación 16 Apoyo al consumidor Apoyo al consumidor 20 Garantía 19 Escriba los números de modelo y serie aquí de Modelo ___________________ de Serie _____________________ Puede encontrar estos números en una etiqueta en el costado del acondicionador de aire Manual del propietario e Instrucciones de Instalación Acondicionadores de Aire ge ...

Page 22: ...ntacto con la compañía que se encarga de recoger su basura para que le indiquen qué hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o remueva la tercera púa tierra del cable eléctrico En pos de la seguridad personal este electrodoméstico debe siempre conectarse a tierra El cable eléctrico de este electrodoméstico está equipado con un enchufe de tres púas tierra que combina con un ...

Page 23: ...ible en la mayoría de las ferreterías La ranura mayor en el adaptador debe estar alineada con la púa mayor en la pared para proporcionar una polaridad apropiada en la conexión del cable eléctrico Cuando se disponga a desconectar el cable eléctrico del adaptador siempre sostenga el adaptador en su lugar con una mano mientras tira del cable eléctrico con la otra mano Si no hace esto la terminal de t...

Page 24: ... pasa por los ciclos de encendido y apagado Este interruptor debe estar en OFF APAGADO para usar los ajustes del ventilador en el control de modo NOTA En algunos modelos la función de ENERGY SAVER AHORRADOR DE ENERGÍA no puede ser ajustada en el acondicionador de aire Deben ser ajustadas usando el control remoto CIRCULAIRE en algunos modelos Para proporcionar circulación de aire continua de lado a...

Page 25: ... de un ajuste COOL FRÍO a OFF APAGADO o a un ajuste de ventilador espere aproximadamente 3 minutos antes de cambiar otra vez al ajuste de COOL FRÍO Modo de FAN Ventilador Use el FAN Ventilador en High F3 ALTO MED F2 MEDIO o LOW F1 BAJO para proporcionar circulación de aire y filtración sin enfriamiento Debido a que los niveles de ventilador únicamente no proporcionan enfriamiento el nivel de tempe...

Page 26: ...IENTO ALTO con el control de temperatura en el número mayor disponible en su teclado Para enfriamiento silencioso durante la noche Seleccione LOW COOL ENFRIAMIENTO BAJO con el control de temperatura en el nivel medio Controles de temperatura El control de temperatura es usado para mantener la temperatura de la habitación El compresor hará ciclo entre encendido y apagado para mantener el mismo nive...

Page 27: ...tenida luego muévalo hasta OFF APAGADO Para circulación del aire de lado a lado continua función enfriamiento solamente ajuste el Circulaire a la posición ON ENCENDIDO Ahorro de energía en algunos modelos El interruptor de ahorro de energía controla el ventilador ON ENCENDIDO El ventilador y el compresor hacen ciclo entre encendido y apagado Esto da como resultado mayores variaciones de temperatur...

Page 28: ...IÓN NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruirán y reducirán su rendimiento 2 1 Bobinas para exteriores Se deben inspeccionar con frecuencia las bobinas en el lado exterior del acondicionador de aire Si las mismas están obstruidas con suciedad u hollín podrían limpiarse profesionalmente Rejilla y caja Apague el acondicionador de aire y retir...

Page 29: ...xión a tierra del cable eléctrico No cambie el enchufe en el cable eléctrico de este acondicionador de aire Los cables caseros de aluminio podrían presentar problemas especiales Consulte a un técnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidadosamente IMPORTANTE Guarde estas instrucciones para uso del inspector local IMPORTANTE Observe todos los códigos y órd...

Page 30: ...echo Parte superior de la espuma de la junta de la ventana Banda de sello de la ventana Panel de acordeón izquierdo Tipo B 3 Tipo C 5 Tornillo 2 Tuerca 2 PARTES INCLUIDAS apariencia puede variar Instrucciones de instalación 10 HERRAMIENTAS QUE NECESITARÁ Un destornillador de estrella Una regla o cinta métrica Lápiz Nivel Tijeras o cuchilla Un destornillador con hoja plana ...

Page 31: ...s de 6 000 8 000 y 10 000 BTU Para AGM10 vea for AGM10 dimensions Modelo AGM10 y modelos de 12 000 y 14 000 BTU 24 mín sin paneles de acordeón 16 mín 27 a 39 con paneles de acordeón REQUISITOS DE UNA VENTANA DE TORMENTAS Un marco de ventana de tormentas no permitirá que el acondicionador de aire se incline hacia el exterior y evitará que drene apropiadamente Para solucionar este problema adhiera u...

Page 32: ... posterior de la banda de sellado del riel de montura superior y únala al fondo del riel de montaje superior Instale el riel de montaje superior con 3 tornillos tipo A en el interior de la caja Inserte los marcos para los paneles de acordeón en el riel de montaje superior y las guías del marco Una los paneles de acordeón al lado de la caja usando 4 tornillos tipo A en cada lado D C B 4 Instruccion...

Page 33: ... en el umbral Una los soportes del umbral al agujero de trayectoria de la caja en relación con la posición seleccionada usando dos tornillos tipo A en cada soporte E D C B A 5 Tornillo Tuerca Soporte del umbral EXTERIOR INTERIOR Guía del marco INSTALE LA CAJA EN LA VENTANA CONT Ajuste el tornillo y la tuerca en cada soporte de forma tal que la caja esté instalada con una inclinación ligera hacia e...

Page 34: ...e de la caja Empuje la parrilla hasta que encaje en su lugar Levante la parrilla de entrada y asegúrela al marco frontal con un tornillo tipo A Baje la parrilla de entrada a su lugar D C B A INSTALE EL SOPORTE DE CIERRE DE LA VENTANA Y LA JUNTA DE ESPUMA SUPERIOR DE LA VENTANA Una el soporte de cierre de la ventana con un tornillo tipo C Corte la parte superior de la espuma de la junta al ancho de...

Page 35: ...mperatura a un número mayor El filtro de aire está sucio Limpie el filtro cada 30 días por lo menos Ver la sección de Instrucciones de Operación La habitación podría haber Cuando el acondicionador de aire se enciende usted estado caliente necesita darle tiempo para que enfrié la habitación El aire frío se está escapando Cerciórese de que los registros de la calefacción no están abiertos y se encue...

Page 36: ... hace Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación Problema Causas posibles Qué hacer Se acumula agua en La humedad es removida Esto es normal por un corto período en áreas con poca la bandeja del aire interno y drenada hacia humedad normal por un período de tiempo más la parte posterior del gabinete postergado en áreas más húmedas donde un ventilador la empuja contra e...

Page 37: ...17 Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación ...

Page 38: ...Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación 18 ...

Page 39: ...tos de la naturaleza de fuerza mayor Daños incidentales o consecuenciales causados por defectos posibles con este acondicionador de aire Daños causados después de la entrega Producto no accesible para facilitar el servicio requerido Lo que no está cubierto Esta garantía se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados U...

Page 40: ...tras su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios ge com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden pedir que se les manden las piezas o accesorios directamente a sus ...

Reviews: