Installation Instructions
WINDOW REQUIREMENTS
•
These instructions are for a standard
double-hung window. You will need to
modify them for other types of windows.
•
The air conditioner can be installed
without the accordion panels if needed
to fit in a narrow window. See the
window opening dimensions.
•
All supporting parts must be secured
to firm wood, masonry or metal.
•
The electrical outlet must be within
reach of the power cord.
1
14
″
min.
22
″
to 36
″
(With accordion panels)
19
″
min.
(Without accordion panels)
6,000, 8,000 and 10,000 BTU models
(See last illustration for AGM10 dimensions)
AGM10, 12,000 and 14,000 BTU models
24
″
min.
(Without accordion panels)
16
″
min.
27
″
to 39
″
(With accordion panels)
STORM WINDOW REQUIREMENTS
A storm window frame will not allow the
air conditioner to tilt toward the outside,
and will keep it from draining properly.
To adjust for this, attach a piece of wood
to the stool.
WOOD PIECES–
WIDTH: 2
″
LENGTH:
Long enough to fit inside the
window frame.
THICKNESS:
To determine the thickness,
place a piece of wood on the stool to
make it 1/2
″
higher than the top of the
storm window frame.
Attach securely with nails or screws
provided by the installer.
1/2
″
higher
than frame
Storm
window
frame
Wood
Stool
2
11