Problem

Possible Causes

What To Do

Air conditioner

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

is unplugged.

into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Power failure.

The unit will automatically re-start in the settings last 
used after the power is restored.

There is a protective time delay (approximately 3 minutes)
to prevent tripping of the compressor overload. For 
this reason, the unit may not start normal cooling for 
3 minutes after it is turned back on.

The current interrupter 

Press the 

RESET

button located on the power cord plug.

device is tripped.

If the 

RESET

button will not stay engaged, discontinue  

use of the air conditioner and contact a qualified service 
technician.

Air conditioner does not

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

cool as it should

blocking the front of the air conditioner.

The temp control may not

In 

COOL

mode, press the 

DECREASE

pad. 

be set correctly.

The air filter is dirty.

Clean the filter at least every 30 days.
See the 

Operating Instructions

section.

The room may have been hot.

When the air conditioner is first turned on, you need to
allow time for the room to cool down.

Cold air is escaping.

Check for open furnace floor registers and cold air
returns.

Set the air conditioner’s vent to the closed position.

Cooling coils have iced up.

See “

Air conditioner freezing up

” below.

Air conditioner

Ice blocks the air flow and

Set the controls at 

HIGH (F3) FAN 

or 

HIGH (F3) COOL 

and

freezing up

stops the air conditioner

set the thermostat to a higher temperature.

from cooling the room.

The remote control  

The batteries are inserted

Check the position of the batteries. They should be 

is not working

incorrectly.

inserted in the opposite (+) and (–) direction.

The batteries may be dead.

Replace the batteries.

Water drips outside

Excessively hot and

This is normal.

humid weather.

Water drips indoors

The air conditioner is not

For proper water disposal, make sure the air conditioner

tilted to the outside.

slants slightly from the case front to the rear.

Water collects in 

Moisture is removed from 

This is normal for a short period in areas with little

base pan

indoor air and drains into

humidity; normal for a longer period in very humid areas.

rear of a cabinet where a fan
blows it against the outdoor
condenser coil.

TIMER feature not 

A power outage or interruption 

In the case of a power outage or interruption, the unit  

working properly

occurred.

TIMER

feature will reset to the original setting. You may 

need to set a new time if desired.

Troubleshooting Tips.

ge.com

Troubleshooting Tips. 
Save time and money!

13

Summary of Contents for AGH10

Page 1: ...ioner 7 Window Installation 8 12 Troubleshooting Tips 13 Normal Operating Sounds 14 Consumer Support Consumer Support 16 Warranty 15 3828A21031F 49 7519 11 05 JR Owner s Manual and Installation Instru...

Page 2: ...ck with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance mus...

Page 3: ...erly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provid...

Page 4: ...the air conditioner to COOL or FAN mode FAN Pad Use to set the fan speed to LOW F1 MED F2 or HIGH F3 TIMER Pad ON When the air conditioner is off it can be set to automatically come on in 1 to 12 hour...

Page 5: ...scriptions For Normal Cooling Select the COOL mode and HIGH F3 or MED F2 fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH F3 fan with a lower set temperature For Qui...

Page 6: ...d regularly If they are clogged with dirt or soot they may be professionally cleaned Outdoor Coils The air filter behind the front grille should be checked and cleaned at least every 30 days or more o...

Page 7: ...2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These...

Page 8: ...cket Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 3 Type C 5 Bolt 2 Nut 2 Frame guide 2 Top mounting rail seal strip Top mounting rail PARTS INCLUDED Appea...

Page 9: ...ame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough...

Page 10: ...and attach the seal to the underside of the window sash A 4 PREPARE THE WINDOW AND THE CASE CONT Carefully insert the plastic frame guides into the bottom of the case on each side Remove the backing f...

Page 11: ...nt on the sill Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support E D C B A 5 Installation Instructions Bolt Nut Sill support OU...

Page 12: ...grille Raise the inlet grille back into place D C B Installation Instructions INSTALL THE WINDOW LOCKING BRACKET AND THE FOAM TOP WINDOW GASKET Attach a support bracket with a Type C screw Cut the fo...

Page 13: ...en the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s ve...

Page 14: ...t the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Wate...

Page 15: ...equential damage caused by possible defects with this air conditioner What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home u...

Page 16: ...kitchen design ideas for people with disabilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to servi...

Page 17: ...el acondicionador de aire 7 Solucionar problemas 13 Sonidos normales de operaci n 14 Apoyo al consumidor Apoyo al consumidor 16 Garant a 15 3828A21031F 49 7519 11 05 JR Manual del propietario e Instru...

Page 18: ...ntenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indiquen qu hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o remueva la tercer...

Page 19: ...alineada con la p a mayor en la pared para proporcionar una polaridad apropiada en la conexi n del cable el ctrico Cuando se disponga a desconectar el cable el ctrico del adaptador siempre sostenga e...

Page 20: ...autom ticamente dentro de 1 a 12 horas en el nivel previo Cada toque ajustar el tiempo en horas OFF APAGADO Cuando el acondicionador de aire est encendido puede ajustarse para que se apague autom tic...

Page 21: ...mperatura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador COOL y LOW F1 BAJO con una temperatura de ajuste media NOTA Si cambia de un ajuste COOL...

Page 22: ...tro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por lo menos cada 30 d as o m s a menudo si fuese necesario Para retirarlo Abra la rejilla de entrada hacia abajo tirando de la...

Page 23: ...xi n a tierra del cable el ctrico No cambie el enchufe en el cable el ctrico de este acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico...

Page 24: ...na Panel de acorde n izquierdo Tipo B 3 Tipo C 5 Tornillo 2 Tuerca 2 Gu a del marco 2 Cinta de sellado del riel de montaje superior Top mounting rail PARTES INCLUIDAS apariencia puede variar Instrucci...

Page 25: ...arco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene apropiadamente Para solucionar este problema adhiera un pedazo de madera a la rep...

Page 26: ...ior de la banda de sellado del riel de montura superior y nala al fondo del riel de montaje superior Instale el riel de montaje superior con 3 tornillos tipo A en el interior de la caja Inserte los ma...

Page 27: ...en el umbral Una los soportes del umbral al agujero de trayectoria de la caja en relaci n con la posici n seleccionada usando dos tornillos tipo A en cada soporte E D C B A 5 Tornillo Tuerca Soporte d...

Page 28: ...a de control de ventilaci n localizada encima de los botones de control de la unidad como se muestra Una la parrilla del frente a la caja insertando las orejillas en la parrilla en las ranuras en el f...

Page 29: ...rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamien...

Page 30: ...ora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante d as lluviosos o con mucha humedad El agu...

Page 31: ...mayor Da os incidentales o consecuenciales causados por defectos posibles con este acondicionador de aire Lo que no est cubierto Esta garant a se extiende al comprador original y cualquier comprador...

Page 32: ...iscapacidades mire nuestra p gina Web hoy mismo Para personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios ge com Aquellos individuos con la calificaci n...

Reviews: