Problem

Possible Causes

What To Do

Air conditioner

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

is unplugged.

into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Power failure.

If power failure occurs, turn the air conditioner 

OFF

.

When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor 
overload.

Air conditioner does not

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

cool as it should

blocking the front of the air conditioner.

The temp control may

On models with touch pads: In 

COOL

mode, press the 

not be set correctly.

DECREASE

pad. 

On models with control knobs, turn the temperature
knob to a higher number. 

The air filter is dirty.

Clean the filter at least every 30 days.
See the 

Operating Instructions

section.

The room may have been hot.

When the air conditioner is first turned on you need to
allow time for the room to cool down.

Cold air is escaping.

Check for open furnace floor registers and cold air 
returns.

Set the air conditioner’s vent to the closed position.

Cooling coils have iced up.

See “

Air conditioner freezing up

” below.

Air conditioner

Ice blocks the air flow

On models with control knobs, set the mode control at 

freezing up

and stops the air conditioner

HIGH FAN 

or 

HIGH COOL

with the temp at 

1

or 

2

.

from cooling the room.

On models with touch pads, set the controls at 

HIGH (F3) FAN 

or 

HIGH (F3) COOL 

and set the thermostat 

to a higher temperature.

The remote control 

The batteries are inserted

Check the position of the batteries. They should be 

is not working

incorrectly.

inserted in the opposite (+) and (–) direction.

The batteries may be dead.

Replace the batteries.

Water drips outside

Excessively hot and

This is normal.

humid weather.

Water drips indoors

The air conditioner is not

For proper water disposal, make sure the air conditioner

tilted to the outside.

slants slightly from the case front to the rear.

Water collects in 

Moisture is removed from 

This is normal for a short period in areas with little

base pan

indoor air and drains into

humidity; normal for a longer period in very humid 

rear of a cabinet where a fan

areas.

blows it against the outdoor
condenser coil.

TIMER feature not 

A power outage or interruption 

In the case of a power outage or interruption, the unit  

working properly

occurred.

TIMER

feature will reset to the original setting. You may 

need to set a new time if desired.

Troubleshooting Tips.

GEAppliances.com

Troubleshooting Tips 
Save time and money! Review the chart below first
and you may not need to call for service.

Summary of Contents for AGF18

Page 1: ...tallation 10 14 Troubleshooting Tips 15 16 Normal Operating Sounds 16 Consumer Support Consumer Support 20 Product Registration 17 18 Warranty 19 3828A20292R 49 7476 11 03 JR Owner s Manual and Installation Instructions www GEAppliances com Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a label on the side of the air...

Page 2: ...aw must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding ...

Page 3: ...ade to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug w...

Page 4: ...ns of room temperature and humidity Normally used when the room is unoccupied Note The fan will continue to run for a short time after the compressor cycles off OFF The fan runs all the time while the compressor cycles on and off This feature must be set at OFF in order to use the fan settings on the mode control Note On some models the ENERGY SAVER feature cannot be set on the air conditioner It ...

Page 5: ...ng Select the COOL mode and LOW F1 fan with a middle set temperature NOTE If you switch from a COOL setting to OFF or to a fan setting wait at least 3 minutes before switching back to a COOL setting FAN Mode Use the FAN at HIGH F3 MED F2 or LOW F1 to provide air circulation and filtering without cooling Since fan only settings do not provide cooling a temperature setting will not be displayed Cons...

Page 6: ...t number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the indoor air will become cooler Turn the knob to a lower number and the indoor air will b...

Page 7: ...desired air direction is obtained then move it to OFF For continuous side to side air circulation cool settings only set the Circulaire switch to ON Air Direction Up and Down Fingertip pressure on the bank of horizontal louvers adjusts the air direction up or down Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results i...

Page 8: ...TION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Grille and Case Turn the air conditioner off and remove ...

Page 9: ...ded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models...

Page 10: ...pe D 2 Carriage Bolt 2 Lock Nut 4 Window locking bracket Frame guide 2 Top mounting rail Top mounting rail seal strip Right accordion panel Foam top window gasket Window sash seal Left accordion panel PARTS INCLUDED Appearance may vary Installation Instructions 10 ...

Page 11: ... power cord 1 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of th...

Page 12: ...ide Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail Install the top mounting rail with 3 type A screws on the inside of the case Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordion panels to the side of the case using 5 type A screws on each side D C B 4 Installation Instructio...

Page 13: ...k nuts in each support so that the case is installed with a slight tilt to the outside Use a level about 1 3 bubble will be the correct case slant to the outside Tighten the bolts CAUTION DO NOT drill a hole in the base pan The unit is designed to operate with approximately 1 2 of water in the base pan Secure the case to the window stool by using 3 type B screws Pull the accordion panels to each w...

Page 14: ...t of the case Push the grille in until it snaps into place Lift the inlet grille and secure the front frame with a type A screw through the front grille Lower the inlet grille back into place D C B A Installation Instructions INSTALL A SUPPORT BRACKET AND THE FOAM TOP WINDOW GASKET Attach a support bracket with a Type C screw Cut the foam top window gasket to the window width Stuff the foam betwee...

Page 15: ...sition Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the air flow On models with control knobs set the mode control at freezing up and stops the air conditioner HIGH FAN or HIGH COOL with the temp at 1 or 2 from cooling the room On models with touch pads set the controls at HIGH F3 FAN or HIGH F3 COOL and set the thermostat to a higher temperature The ...

Page 16: ...g picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit The fan may run even when the compre...

Page 17: ... will be completely satisfied with our service protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protectio...

Page 18: ...ber Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Read your Owner s Manual careful...

Page 19: ...ovide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God Incide...

Page 20: ...warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to...

Page 21: ...nas 10 14 Ideas para la identificación y reparación de problemas 15 16 Sonidos normales de operación 16 Apoyo al consumidor Apoyo al consumidor 20 Garantía 19 Manual del Propietario e Instrucciones de Instalación Escriba el modelo y número de serie aquí Número de modelo__________________ Número de serie____________________ Usted puede encontrar estos números al costado del acondicionador de aire A...

Page 22: ...ederan deben ser removidos antes de desecharlos Si usted planea deshacerse de algún producto que contenga refrigerantes póngase en contacto con la compañía que se encarga de recoger su basura para que le indiquen qué hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o retire la tercera púa tierra del cable eléctrico En pos de la seguridad personal este electrodoméstico debe ser siem...

Page 23: ...iente listado UL disponible en la mayoría de las ferreterías La ranura mayor en el adaptador debe estar alineada con la púa mayor en la pared para proporcionar una polaridad apropiada en la conexión del cable eléctrico Cuando se disponga a desconectar el cable eléctrico del adaptador siempre sostenga el adaptador en su lugar con una mano mientras tira del cable eléctrico con la otra mano Si no hac...

Page 24: ...ue el compresor entre en el ciclo de apagado OFF APAGADO El ventilador funciona todo el tiempo mientras el compresor hace ciclo entre encendido y apagado Esta función debe estar colocada en OFF APAGADO para usar las funciones del ventilador en el modelo de control Nota En algunos modelos la función de ENERGY SAVER AHORRADOR DE ENERGÍA no puede ser ajustada en el acondicionador de aire Deben ser aj...

Page 25: ...ambia de un ajuste COOL FRÍO a OFF APAGADO o a un ajuste de ventilador espere aproximadamente 3 minutos antes de cambiar otra vez al ajuste de COOL FRÍO Modo de FAN Ventilador Use el FAN Ventilador en High F3 ALTO MED F2 MEDIO o LOW F1 BAJO para proporcionar circulación de aire y filtración sin enfriamiento Debido a que los niveles de ventilador únicamente no proporcionan enfriamiento el nivel de ...

Page 26: ... el control de temperatura en un número mayor disponible en su teclado Para enfriamiento silencioso durante la noche Seleccione LOW COOL ENFRIAMIENTO BAJO con el control de temperatura en el nivel medio Controles de temperatura El control de temperatura es usado para mantener la temperatura de la habitación El compresor hará ciclo entre encendido y apagado para mantener el mismo nivel de temperatu...

Page 27: ... CIRCULADOR DE AIRE a la posición ON ENCENDIDO y déjelo así Dirección del aire Hacia arriba y hacia abajo Una presión sencilla con los dedos en parte posterior de la persianita horizontal ajustará la dirección del aire hacia arriba o hacia abajo Ahorro de energía en algunos modelos El interruptor de ahorro de energía controla el ventilador ON ENCENDIDO El ventilador y el compresor hacen ciclo entr...

Page 28: ...N NO opere el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruirán y reducirán su rendimiento 2 1 Bobinas para exteriores Las bobinas en el lado exterior del acondicionador de aire debe ser inspeccionada regularmente Si la misma está obstruida con suciedad u hollín podría ser limpiada profesionalmente con vapor y nosotros en GE podemos proporcionarle tales serv...

Page 29: ...io por el sobrecalentamiento de los alambres REQUISITOS ELÉCTRICOS PRECAUCIÓN Bajo ninguna circunstancia corte o remueva la tercera púa conexión a tierra del cable eléctrico No cambie el enchufe en el cable eléctrico de este acondicionador de aire Los cables caseros de aluminio podrían presentar problemas especiales Consulte a un técnico electricista calificado ANTES DE INICIAR Lea estas instrucci...

Page 30: ...Soporte de cierre de la ventana Guía del marco 2 Riel de montaje superior Cinta de sellado del riel de montaje Panel de acordeón derecho Parte superior de la espuma de la junta de la ventana Banda de sello de la ventana Panel de acordeón izquierdo PARTES INCLUIDAS aparencia puede variar Instrucciones de instalación 10 ...

Page 31: ... a 41 con paneles de acordeón 261 4 mínimo sin paneles de acordeón REQUISITOS DE UNA VENTANA DE TORMENTAS Un marco de ventana de tormentas no permitirá que el acondicionador de aire se incline hacia el exterior y evitará que drene apropiadamente Para solucionar este problema adhiera un pedazo de madera a la repisa PIEZAS DE MADERA ANCHO 2 LONGITUD Suficiente longitud para ajustarse al interior del...

Page 32: ...parte posterior de la banda de sellado del riel de montura superior y únala al fondo del riel de montaje superior Instale el riel de montaje superior con 3 tornillos tipo A en el interior de la caja Inserte los marcos para los paneles de acordeón en el riel de montaje superior y las guías del marco Una los paneles de acordeón al lado de la caja usando 5 tornillos tipo A en cada lado D C B 4 Instru...

Page 33: ... una pequeña inclinación hacia el exterior Use un nivel aproximadamente 1 3 de burbuja será la inclinación correcta hacia el exterior Apriete los tornillos PRECAUCIÓN NO taladre un agujero en el cárter base La unidad está diseñada para operar con aproximadamente 1 2 de agua en el cárter base Asegure la caja a la repisa de la ventana usando 3 tornillos tipo B Tire de los paneles de acordeón hacia c...

Page 34: ...e de la caja Empuje la parrilla hasta que encaje en su lugar Levante la parrilla de entrada y asegúrela al marco frontal con un tornillo tipo A Baje la parrilla de entrada a su lugar D C B A INSTALE EL SOPORTE DE CIERRE DE LA VENTANA Y LA JUNTA DE ESPUMA SUPERIOR DE LA VENTANA Una el soporte de cierre de la ventana con un tornillo tipo C Corte la parte superior de la espuma de la junta al ancho de...

Page 35: ...amiento Ver Acondicionador de aire congelándose más adelante se congelaron El acondicionador de aire El hielo bloquea el flujo de En modelos con los botones de control coloque el se está congelando aire hacia el acondicionador control de modo en HIGH FAN Ventilador Alto ó de aire evitando que se enfríe HIGH COOL Frío Alto con la temperatura en 1 ó 2 la habitación En los modelos con teclas de toque...

Page 36: ...ompresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante días lluviosos o con mucha humedad El agua podría derramarse y gotear desde el lado externo de la unidad El ventilador podría funcionar aun si el compresor no lo hace Problema Causas posibles Qué hacer Se acumula agua en la La humedad es removida del Esto es normal por un corto período en áreas con poca bandeja ...

Page 37: ...17 Apoyo al consumidor Solución de problemas Instrucciones de operación Instrucciones de seguridad Instrucciones de instalación Notas ...

Page 38: ...18 Notas Apoyo al consumidor Solución de problemas Instrucciones de operación Instrucciones de seguridad Instrucciones de instalación ...

Page 39: ... mantenimiento razonable y necesario En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisión por parte de un técnico individual Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallos debido a la corrosión en modelos que no están protegidos contra la corrosión Daño al producto causado por voltaje inapropiado hacia el equipo accidente...

Page 40: ...detalles sobre descuentos especiales disponibles mientras su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios GEAppliances com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden pedi...

Reviews: