background image

Summary of Contents for AEN08 Series and

Page 1: ...15 16 Warranty for Customers in Canada 17 Warranty for Customers in the USA 18 AEN08 Climatiseur Lo section ffonqoise commence _ Io poge 19 Acondicionodor deoire Lo secci6n en espohol empiezo en Io p...

Page 2: ...to do These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R2...

Page 3: ...erious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Conditioner GEAppliances com READAND FOLL...

Page 4: ...ile setting O Fan Speed Pads Useto set the fan speed to Low Med High or Auto on the unit NOTE On the remote control use the fan speed Increase Decrease pads to set the fan speedsto Low Med or High Use...

Page 5: ...ider variations of room temperature and humidity Normally used when the room is unoccupied NOTE The fan may continue to run for a short time after the compressor cycles off OFF The fan runs all the ti...

Page 6: ...CAUTION NOT o erote the air conditioner without o filter becousedirt and lint will clog it and reduce performance Outdoor Coils The coils on the outdoor side of the air conditioner should be checked r...

Page 7: ...n to use is only a 2 prong outlet it is your responsibility to hove it replaced with o properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or cir...

Page 8: ...ARTS INCLUDED appearance may vary Foam top window gasket Window sash seal thin adhesive backed Left accordion panel Top mounting rail Top meO _ Right accordion panel Window locking Type A 6 Type B 5 T...

Page 9: ...h to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the sill to make it 1 2 higher than the top of the storm window frame or the vinyl frame Attach securely...

Page 10: ...long the front edge Top mounting rail _ emove backing from seal strip FRONTVIEW Top mounting rail I Sealstrip rsl INSTALL THE TOP MOUNTING RAIL ONTO THE CASE Attach the top mounting rail onto the top...

Page 11: ...Pull the accordion panels to each window sash track Attach them on each side to the window sash and the window sill using 4 Type C screws r91 INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET CAUTIO...

Page 12: ...one on each side of the case IMPORTANT The ground screws must be reinstalled to ensure a proper ground 5 Reinstall the control to the panel housing be replacing the three screws you removed earlier J...

Page 13: ...cool down Cold air is escaping Checkfor open furnace registers and cold air returns Cooling coils hove iced up See Air conditioner freezing up below Air conditioner freezing up Ice blocks the air flow...

Page 14: ...Notes 14...

Page 15: ...Notes 15...

Page 16: ...Notes 16...

Page 17: ...ocation where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to...

Page 18: ...necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models...

Page 19: ...tance a la clientble 36 Garantie 35 Enregistrement du titre de propriOt_ 33 34 AEN08 Produits homologuds ENERGY STAR ENERGY STAR En rant que partenaire d ENERGY STAR GE a dO terminal que ce produit dt...

Page 20: ...le de l dliminafion Ces systames de climatisafion R410A demandent clue les contracteurs et les techniciens utilisent des outils de l dquipement et des mesures de sdcuritd homology pour une utilisadon...

Page 21: ...blessures graves ou la mort NE PASutiliser de rallonge avec ce climatiseur NE PASutiliser de parasurtenseur ou d adaptateur _ prises multiples avec ce climatiseur www electromenagersge co LISEZ ETSUI...

Page 22: ...tilis_es pour r_ gler la vitesse du ventilateur de l appm eil sur Low faible Med moyenne High elevde ou Auto mlmmatique REMARQUE Sur la t_l_commande udlisezles touches Increase Decrease pour r_gler la...

Page 23: ...ompresseur Ceci pemmt une plus grande variation de la temp amre et du taux d humidit_ dm_s la piece Est en g _ ralutilis lorsque la piOce est inoccup e REMARQUE Leventilateur peutcontinuer _fonctionne...

Page 24: ...filtre sous peinedele boucher avecdelapoussiere et delacharpie et derOduire son efficacitO Serpentins ExtOrieurs Les serpentins simds du c6td extdrieur du climafiseur dokent _tre rdg uliOrement vd rif...

Page 25: ...remplacer par une prise triphasee correctement raise a la terre Certains modules necessitent une prise raise a la terre de 230 208 Volts AC proteg6e par un fusible a action differ6e ou _ par un disjo...

Page 26: ..._ _ _ mousse de la _ _ fenetre Joint d 6tancheit6 de la fen6tre guillotine fin adhesif au dos Panneau en accord6on gauche _ Bande d_ du rail de _age J superleur Rail de montage superieur Panneau en ac...

Page 27: ...LONGUEUR Suffisamment long pour se Ioger I interieur du cadre de la fen6tre EPAISSEUR Pour determiner 1 6paisseur placez un morceau de bois sur le rebord de la fen6tre de fa on ace que le morceau de b...

Page 28: ...ntage superieur Illi _ etirez la pellicule de la bande d etanch6it6 VUEFRONTALE Rail de montage superieur J I Bande d etanch6it6 D INSTALLATION DURAILDEMONTAGE SUPI_RIEUR SURLELOGEMENT Fixez le rail d...

Page 29: ...s panneaux en accordeon vers chaque rail de la fen re a guillotine Fixez les de chaque c6te du cadre et du rebord de la fen6tre a I aide de 4 vis de type C INSTALLATION D UNE FERRURE DE SUPPORT ETDU J...

Page 30: ...rees plus t6t une de chaque c6te IMPORTANT Lesvis de mise a la terre d0ivent _tre remises en place pourgarantir une mise a la terre adequate d INSTALLATION DU CLIMATISEURDANS SONLOGEMENT SUITE Montez...

Page 31: ...la circulation Sur les modules dotds de boutons de commande rdglez le mode g_le d air et empOche le climatiseur sur High Fan vitessedu ventilateur dlevde ou High C001 fort de refroidir la chambre ref...

Page 32: ...Notes 32...

Page 33: ...Notes 33...

Page 34: ...Notes 34...

Page 35: ...nt off ilest accessible pax un technicien parficulier Le remplacement des fl_sibles de la maison ou la rdacfivation des disjoncteurs Les pannes occasionndes pax la corrosion sur les modbles qui ne son...

Page 36: ..._nles leurs dlecu omdnagers peuvent recevoir pibces et accessoires directement ala maison cartes VISA MasterCard et Discover acceptdes Lesdirectives stipulees danslepresent manuelpeuvent etreeffectuee...

Page 37: ...Sonidos de operaci6n normales 49 Servicio al consumidor Garantia 50 Servicio al consumidor 51 AEN08 Producto etiquetado ENERGY STAR _ Como socio de ENERGY STAR GE ha confirmado que este producto cumpl...

Page 38: ...encarga de recoger su basura para que le indiquen qud hacer Estos sistemas de acondicionadores de aire R410A requieren quelos contratistas y t_cnicos usen herramientas equipos y estandares de seg_rida...

Page 39: ...NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi6n ni adaptadores pare mOItiples tomacorrientes con este Acondicionodor de Aire de Ventono GEAp...

Page 40: ...h Alto o Auto AutomStica en la unidad NOTA en el control remoto utilice las teclas Aumento ReducciOn velocidad de ventilador pare ajustar la velocidad del venfilador en Low Baj0 Med Medi0 o High Ait0...

Page 41: ...abitaci6n no estfi ocupada NOTA puede queelventilador sigafuncionando durante un cortotiempodespu0s dedesactivarse elciclodelcompresor OFF APAGADO _E1 ventilador flmciona todo el fiempo mienu as que e...

Page 42: ...un lm_avajillas _4 PRECAUCION No OPERE el acondicionador deairesinelfiltrodebido aquela suciedad y laspelusas Io obstruirSn y reducirSn surendimiento Bobinas para exteriores Se deben inspeccionar con...

Page 43: ...S Algunos modelosrequierentomacorrientesde 115 120 voltios de corrientealternay 60 Hzconectados a tierra protegidoscon unfusiblede dilataciOnde tiempo de 15amperios o uncortacircuitos Elenchufe detres...

Page 44: ...japlana L iz Nivel Unaregla o cintam6trica PARTES INCLUIDAS Empaque superior de espu_ de la ventana Sellodel marco dela ventana fino conadhesivo enla parteposterior Panelde acorde6n izquierdo Rieldemo...

Page 45: ...entemente largo comoparaajustarenel interiordelmarco delaventana GRUESO Para determinar elgrueso coloque unpedazo de madera enelumbralparahacerla 1 2 mSs altaquelaparte superior delmarco delaventana d...

Page 46: ...Rieldemontaje superior _ etire laparte postenor dela ban de sellado VISTAFRONTAL Rieldemontajesuperior J I Banda desellado I 611NSTALE ELRIELDEMONTAJESUPERIOR ENLACAJA Pegueel riel de montajesuperior...

Page 47: ...de acordeOnhacia cada paso del marco de la ventana Onalos a cada lado del marco de la ventana y el umbral de la ventana usando 4 tornillos tipo C INSTALE UNSOPORTE DECIERRE Y LAJUNTADE ESPUMA SUPERIO...

Page 48: ...daladode lacaja IMPORTANTE Lostornillos a tierra deben ser instalados a nuevo para asegurar una conexiOna tierra correcta Reinstaleel control enel espaciodel panelreemplazando lostres tornillos que re...

Page 49: ...le_Cacci6n no estfin abiertos v se encuentran retornando el aire fifo Las bobinas deenfriamiento Vet Acondicionador deairecongelandose rodsadelmlte secongelaron E acondicionador deaire seesta congelan...

Page 50: ...arevision porparte deuntOcnico individual Reemplazo defusibles delacasao reajuste delsistema decircuitos Fallos debido a lacorrosion enmodelos quenoestSn protegidos contralacorrosion Da_oal producto c...

Page 51: ...mienu_s su ga _antfa est_ adn acfiva Puede comprarla en lfnea en cualquier momento o llamar al 800 626 2224 dumnte horas normales de oficina GE Consumer Home Services estar_ adn ahf cuando su garantf...

Page 52: ...u can purchase it on line anydme ox call 800 626 2224 during normal business hours GE Consumer Home Services will soil be there after your warranty expires InCanada call1 888 261 2133 Parts andAccesso...