STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep it
from draining properly .
To adjust for this, attach a piece of wood to the sill .
WOOD PIECES
WIDTH: 2”
LENGTH
:
Long enough to fit inside the window
frame .
THICKNESS:
To determine the thickness, place a
piece of wood on the sill to make it 1/2
″
higher
than the top of the storm window frame or the vinyl
frame .
Attach securely with nails or screws provided by the
installer .
Installation Instructions
WINDOW REQUIREMENTS
•
These instructions are for a standard double-hung
window . You will need to modify them for other types
of windows .
•
All supporting parts must be secured
to firm wood, masonry or metal .
•
The electrical outlet must be within reach of the
power cord .
•
Follow the dimensions in the table and illustration
for your model .
1
18 15/32”
(With accordion panels)
PREPARE THE AIR CONDITIONER
Pull down the front panel and remove the filter .
Remove the front panel by lifting up at an
angle .
Remove the four front screws . Save them for
reinstalling the front housing .
Grasp the lower corners of the grille while
pressing in on the case sides with your finger
tips . Pull out to release and lift it up .
NOTE: Do not pull the bottom edge toward you
more than 3” or you may damage the tabs of
the grille .
When the front grille is removed the control
panel will still be attached by a harness . Turn
the grille around so you can see the back side
of the grille . Remove the 2 screws to separate
the control panel housing from the grille .
NOTE: Be sure to save these screws. You will
need them later in the installation.
3
A
B
26”- 41”
2
1/2
″
higher
than storm
window
frame
Storm window
frame
Wood
Sill
1/2
″
higher
than vinyl frame
(on some windows)
Vinyl frame
9
C
D
Remove Screws