– 40 –
in order to insure proper reinstallation.
4.
Remove the power cord ground wire from
the oven chassis. Note that this screw is
a machine screw with fine threads. Be
sure to mark this screw for proper rein-
stallation.
5.
Disconnect the two wire connectors from
the fuse holder.
6.
Disconnect the two red wires from the vent
motor capacitor.
6.
Disconnect the two power cord connec-
tor plugs and remove the power cord.
7.
Disconnect the upper halogen blower pair
connector plugs (one blue and one clear/
white).
8.
Disconnect the humidity sensor wire from
the smart board (red connector plug).
9.
Disconnect the oven cavity T.C.O. quick
disconnect plug (2 pin yellow quick dis-
connect plug) located in the same prox-
imity as the humidity sensor wires.
10.
CAUTION
Note the wire retainer clip in
the following illustration. This clip holds
the oven cavity thermistor wires. Be sure
to remove these wires from this clip prior
to proceeding with the removal of the up-
per halogen blower/lamp assembly. If you
do not remove these wires you can
damage or break them when removing
11. Remove the 12 screws securing the
blower/lamp assembly to the oven chas-
sis.
UPPER
HALOGEN
BLOWER
PLUG
OVEN
CAVITY
T.C.O.
PLUG
UPPER
HALOGEN
PLUGS
HUMIDITY
SENSOR
PLUG
WIRE
RETAINER
CLIP
BOTTOM SIDE OF UPPER HALOGEN
BLOWER/LAMP ASSEMBLY
the blower/lamp assembly. They must
be removed in order to remove the blower/
lamp assembly.
A
A
A
A
A
A
A
A
B
B
B
B
A
UPPER HALOGEN
BLOWER/LAMP ASSEMBLY
REMOVAL
THERMISTOR
LEADS
CONNECTOR
PLUG
CAPACITOR
H.V. WIRES
GROUND
WIRE
VENT MOTOR
CAPACITOR
FUSE
HOLDER
Summary of Contents for Advantium SCA2000BCC
Page 53: ... 51 ...