Specifications 

 
Voltage 

Regulated 24 VDC, 24 VFWR 

Strobe operating 
current 

See Table 3 

Light output 

Selectable at 15, 30, 75, and 95 cd 

Sound level output 

See  

Default settings 
 Signal 
 

Sound level output 

 Strobe 

signal 

 output 

 
Temporal 
High dB 
1 flash per second (fps) 

Wire size 

12 to 18 AWG (0.75 TO 2.50 mm²) 

Compatible electrical 
boxes 

North American 4 in. square electrical box, 
2-1/8 in. deep (no extension ring) 

Operating environment
 Temperature
 Relative 

humidity 

 
32 to 120°F (0 to 49°C) 
0 to 93% noncondensing 

 

Regulatory information 

 
Manufacturer 

GE Security, Inc., 8985 Town Center Parkway, 
Bradenton, FL 34202, USA 

Year of 
manufacture 

The first two digits of the DATE MFG number (located
on the product identification label) are the year of 
manufacture 

UL/ULC rating 

Regulated 24 DC and 24 FWR 
This device was tested to the regulated 24 DC/FWR 
operating voltage limits of 16 V and 33 V. Do not 
apply 80% and 110% of these values for system 
operation. 

Environmental class  UL: Indoor 

Synchronization 

Meets UL 1971 requirements. Maximum allowed 
resistance between any two devices is 20 

. Refer 

to specifications for the synchronization control 
module, this strobe, and the control panel to 
determine allowed wire resistance. 

Agency listings 

Meets ULC-S525, ULC-S526 
UL 464. UL 1638 and UL 1971 

 

Summary of Contents for ADTGC-HDVM

Page 1: ...ds and Canadian Electrical Code Part 1 Section 32 and CAN ULC S524 Standard for the Installation of Fire Alarm Systems and in accordance with the local authorities having jurisdiction Table 2 Compatible synchronization module models Description Number Auto sync output module SIGA CC1S SIGA MCC1S GSA CC1S GSA MCC1S Genesis signal master remote mount ADTG1M RM MG1M RM EG1M RM XLSG1M RM G1M RM ZG1M R...

Page 2: ... 50 45 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 1 2 1 Angle 2 Percentage of rated output Note Horizontal and vertical outputs have the same pattern Wiring Figure 4 Wiring Diagram 1 2 1 From NAC output 2 To next NAC output Note Signal polarity is sh...

Page 3: ...ak output at regulated 24 VDC set for temporal tone Table 7 Audible directional characteristics vertical pattern Angle 1 Sound output dBA 2 90 Ref 0 Ref 65 and 135 3 55 and 140 6 1 Angles are measured from a perpendicular axis positive angles are up 2 Peak output at regulated 24 VDC set for temporal tone Figure 6 Light output profile 0 20 40 60 80 100 120 140 160 0 5 10 15 20 25 30 35 40 45 50 55 ...

Page 4: ...formation Manufacturer GE Security Inc 8985 Town Center Parkway Bradenton FL 34202 USA Year of manufacture The first two digits of the DATE MFG number located on the product identification label are the year of manufacture UL ULC rating Regulated 24 DC and 24 FWR This device was tested to the regulated 24 DC FWR operating voltage limits of 16 V and 33 V Do not apply 80 and 110 of these values for ...

Reviews: