background image

49-7759-1

OPERA

TING INSTRUCTIONS

Controls

Controls

NOTE: 

 When the bucket is full or removed, the controls 

cannot be set.

1.    Power Pad

  Press to turn the dehumidifier on and off.

2.   Filter Timer

$IWHUKRXUVRIRSHUDWLRQWKH&OHDQWKH)LOWHU

indicator light will glow to remind you to clean the filter. 

Remove the filter and clean it. 

3UHVVWRWXUQRIIWKH&OHDQWKH)LOWHUOLJKW6HHWKH&DUH

and Cleaning section.

3. 

 

  Humidity Set Control Pads

7KHKXPLGLW\OHYHOFDQEHVHWZLWKLQDUDQJHRI

5+5XPLGLW\WR5+5XPLGLW\
LQLQFUHPHQWVRUDW16IRUFRQWLQXRXVRSHUDWLRQ7R
VHWWKHXQLWIRUFRQWLQXRXVRSHUDWLRQSUHVVWKHźSDG
XQWLOWKHVFUHHQUHDGV16

  NOTE: 

,I161RQVWRSLVVHOHFWHGWKHGHKXPLGLILHUZLOO

RSHUDWHFRQWLQXRXVO\DWLWVPD[LPXPGHKXPLGLILFDWLRQ

settings if attached to a hose to drain or until the bucket 

is full.

)RUGULHUDLUSUHVVWKHźSDGDQGVHWWRDORZHU

SHUFHQWYDOXH

)RUGDPSHUDLUSUHVVWKHŸSDGDQGVHWWRDKLJKHU

SHUFHQWYDOXH

  When you first use the dehumidifier, set the humidity 

FRQWUROWRRU$OORZDWOHDVWKRXUVIRUWKH

dehumidifier to achieve the humidity level. If you still 

have damper air than desired, set the humidity level 

WRDORZHUVHWWLQJRUVHOHFW1RQVWRSIRUPD[LPXP

dehumidification.

4.   Display

6KRZVWKHVHWKXPLGLW\OHYHOZKLOHVHWWLQJWKHQVKRZV

WKHDFWXDO±DFFXUDF\URRPKXPLGLW\OHYHO

5.  Fan Speed Pad

  Controls the fan speed.

  Press to select either High, Medium or Low fan 

speed.

6HWWKHIDQFRLJKIRUPD[LPXPPRLVWXUH

removal. When the humidity has been reduced and 

quiet operation is preferred, set the fan control to 

Medium or Low.

6.   Delay Off

  While the dehumidifier is in operation, press this pad to 

VHWLWWRDXWRPDWLFDOO\WXUQRIILQKRXUVRUKRXUV

Other Features

Empty Light

Glows when the bucket is ready to be emptied, or when the 

bucket is removed or not replaced in the proper position.

Alarm

If the bucket is full or missing for more than 3 minutes, an 

DODUPZLOOVRXQGIRUDERXWVHFRQGVWRUHPLQG\RXWR

empty and replace the bucket.

Auto Shut Off

7KH:DWHU/HYHO&RQWURO6ZLWFKVKXWVRIIWKHGHKXPLGLILHU

when the bucket is full, or when the bucket is removed 

RUQRWUHSODFHGLQWKHSURSHUSRVLWLRQ127()DQZLOO
FRQWLQXHWRUXQDSSUR[LPDWHO\PLQXWHVDIWHUEXFNHWLV

removed.

Auto Defrost

When frost builds up on the evaporator coils, the 

compressor will cycle off and the fan will continue to run 

until the frost disappears.

Power Outage

In the case of a power outage or interruption, the unit will 

automatically restart, in the settings last used, after the 

power is restored.

Nonstop

On

Filter

Power

-

+

Fan

Hold 3 Sec To Rest

Filter

Timer

Delay

Off

Empty

%XFNHW)XOOOLJKWLQGLFDWHV

bucket needs to be 

emptied or is not in place 

in the unit

KRXURUKRXU

 

delay off  

indicator lights 

  Continuous 

Operation on 
indicator light

Power On 

indicator light

&OHDQWKH)LOWHU

indicator light

High, Medium 

and  Low fan 
indicator light

Summary of Contents for ADEW70

Page 1: ...k license OWNER S MANUAL DEHUMIDIFIER 49 7759 1 10 18 GEA ADEW30 ADEW50 ADEW70 SAFETY INFORMATION 3 OPERATING INSTRUCTIONS Controls 4 How the Dehumidifier Operates 5 Automatic Defrost 5 Choosing a Loc...

Page 2: ...to every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need...

Page 3: ...must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do R QRW XVH RXWGRRUV 7KLV GHKXPLGLILHU LV...

Page 4: ...d Pad Controls the fan speed Press to select either High Medium or Low fan speed 6HW WKH IDQ FRQWURO WR LJK IRU PD LPXP PRLVWXUH removal When the humidity has been reduced and quiet operation is prefe...

Page 5: ...tored 8VH WKH GHKXPLGLILHU LQ D EDVHPHQW WR KHOS SUHYHQW moisture damage 7KH GHKXPLGLILHU PXVW EH RSHUDWHG LQ DQ HQFORVHG DUHD to be most effective ORVH DOO GRRUV ZLQGRZV DQG RWKHU RXWVLGH RSHQLQJV WR...

Page 6: ...QLW 2 Open the drain cover on the side of the unit 7KUHDG D JDUGHQ KRVH QRW VXSSOLHG RQWR WKH QR OH FXW to length and lead it to the floor drain 5HSODFH WKH EXFNHW LQ WKH XQLW NOTE 7KH EXFNHW PXVW EH...

Page 7: ...27 RSHUDWH WKH GHKXPLGLILHU without a filter because dirt and lint will clog it and reduce performance NOTE Avoid using a dishwasher to clean the filter Grille and Case To clean the case 8VH ZDWHU DQG...

Page 8: ...U DW 16 1RQVWRS IRU PD LPXP dehumidification Doors and windows may not be closed tightly Check that all doors windows and other openings are securely closed Clothes dryer may be blowing moisure laden...

Page 9: ...49 7759 1 9 Notes NOTES...

Page 10: ...49 7759 1 NOTES Notes...

Page 11: ...d necessary maintenance Replacement of house fuses or resetting of circuit breakers DLOXUH GXH WR FRUURVLRQ RQ PRGHOV QRW FRUURVLRQ protected Damage to the product caused by improper power supply volt...

Page 12: ...DEOH ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty RU FDOO...

Page 13: ...MANUAL DESHUMEDIFICADOR 49 7759 1 10 18 GEA ADEW30 ADEW50 ADEW70 INFORMACI N DE SEGURIDAD 3 INSTRUCCIONES DE OPERACI N Controles 4 C mo funciona el deshumedificador 5 Descongelado autom tico 5 Selecci...

Page 14: ...reemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Registre...

Page 15: ...s en la proximidad de ste o alg n otro electrodom stico 1R XVH HO GHVKXPHGLILFDGRU HQ H WHULRUHV VWH GHVKXPHGLILFDGRU HVWi GLVHxDGR H FOXVLYDPHQWH SDUD DSOLFDFLRQHV UHVLGHQFLDOHV GH LQWHULRU 1R GHEH X...

Page 16: ...cionar la velocidad del ventilador en alta High medio Medium o bajo Low Coloque el control del ventilador a alta High velocidad para lograr remover la mayor cantidad de humedad Cuando la humedad haya...

Page 17: ...HQ HO VyWDQR SDUD D XGDU D prevenir los da os causados por la humedad El deshumedificador debe usarse en reas cerradas para mayor efectividad Cierre todas las puertas ventanas y otras aberturas hacia...

Page 18: ...rosque una manguera para jard n no provista en la boquilla cut to length y dir jala al drenaje de piso 9XHOYD D FRORFDU HO WDQTXH HQ OD XQLGDG NOTA El tanque debe estar en su lugar y bien sujeto para...

Page 19: ...ido a que la suciedad y las pelusas lo obstruir n y reducir n su rendimiento NOTA Evite usar una m quina lavavajillas para limpiar el filtro Rejilla y gabinete Para limpiar el gabinete 8VH DJXD XQ GHW...

Page 20: ...DUD obtener una m xima deshumidificaci n Las puertas y ventanas no est n cerradas completamente Revise que todas las puertas ventanas y otras aberturas est n cerradas completamente El secador de ropa...

Page 21: ...49 7759 1 9 Notas NOTAS...

Page 22: ...49 7759 1 NOTAS Notas...

Page 23: ...UHVXOWDGR GH PRGLILFDFLRQHV VREUH el mismo o debido a un uso irrazonable incluyendo la falta de mantenimiento razonable o necesario 5HHPSOD R GH IXVLEOHV GHO KRJDU R UHLQLFLR GH GLV XQWRUHV DOODV FRPR...

Page 24: ...st n disponibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los Servicios de GE Appliances a n HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEAppl...

Reviews: