background image

Center the supporting bracket in the

window against the stool.
Attach it to the sill with two screws.

B

A

Install the Supporting Bracket

Safety Instructions

Operating Instructions

Care and Cleaning

Installation Instructions

Troubleshooting T

ips

Customer Service

Read completely, then follow step-by-step.

Window Requirements

These instructions are for a standard

double-hung window. You will need to

modify them for other types of windows.

All supporting parts must be secured to 

firm wood, masonry or metal.

The electrical outlet must be within 

reach of the power cord. Do not use an

extension cord.

Window opening dimensions are for a 

standard double-hung window.

14

min.

23

to 36

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will

keep it from draining properly. To adjust for

this, attach a piece of wood to the stool.

WOOD PIECES:

WIDTH:

2

LENGTH: 

Long enough to fit inside the 

window frame.

THICKNESS: 

To determine the thickness, 

place a piece of wood on the stool to make it

1/2

higher than the top of the storm window

frame.
Attach securely with nails or screws provided

by the installer.

1/2

higher

than frame

Storm

window

frame

Wood

Stool

1

2

3

9

Stool

Screws

Outside

Inside

Supporting
Bracket

Sill

Summary of Contents for ACV05

Page 1: ...Room Air Conditioners Pub No 49 7383 JR 8 99 ACV05 Owner s Manual Installation Instructions GE Appliances ...

Page 2: ... buying GE We appreciate your purchase and hope you will continue to rely on us whenever you need quality appliances for your home Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner READ THIS MANUAL GE You A Service Partnership F...

Page 3: ...individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires See the Installation Instructions Electrical Requirements section for specific electrical connection requirements HOW TO CONNECT ELECTRICITY Use this appliance only for its ...

Page 4: ...t a temporary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand wh...

Page 5: ...t 4 For Maximum Cooling Select HIGH COOL with the temp control at 8 For Quieter Nighttime Cooling Select LOW COOL with the temp control at 4 Temp Control The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the indoor air will become cooler Turn the knob to a lower numb...

Page 6: ...m soapy water Rinse and let the filter dry before replacing it Do not expose the filter to heat or direct sunlight when drying CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be profession...

Page 7: ...prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall o...

Page 8: ...ctions Care and Cleaning Operating Instructions Safety Instructions 8 Window installation instructions Read these instructions completely and carefully Parts Included Screws 5 Window locking bracket Foam top window gasket Air conditioner Supporting bracket 1 ...

Page 9: ...t be within reach of the power cord Do not use an extension cord Window opening dimensions are for a standard double hung window 14 min 23 to 36 Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit insi...

Page 10: ... window has a handle remove it Center the air conditioner in the window with the bottom rail between the window stool and the bracket B A 4 Lower the window Front grille Inside Outside Bracket Bottom rail Stool Install the Window Filler Panels and Locking Bracket Extend the filler panels to fill the window opening Secure the panels using two screws one on each side Attach the window locking bracke...

Page 11: ...air conditioner off and disconnect the power cord Wait 5 10 minutes before moving the air conditioner to allow the water to drain from the coil into the base pan Remove the foam gasket from between the windows Remove the window locking bracket Remove the screws securing the sliding panels on each side Close the sliding panels Keeping a firm grip on the air conditioner raise the window and carefull...

Page 12: ...rn the knob to a higher number The highest not be set high enough setting provides maximum cooling The air filter is dirty Clean the filter at least every 30 days See the Care and cleaning of the air conditioner section The room may have When the air conditioner is first turned on you need been hot to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers ...

Page 13: ...pletely satisfied with our service protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered...

Page 14: ... 432 2737 3 Read your Owner s Manual carefully It will help you operate your new appliance properly If you have questions or need more information call the GE Answer Center 800 626 2000 Model Number Serial Number Important If you did not get a registration card with your product detach and return the form below to ensure that your product is registered Consumer Product Ownership Registration Model...

Page 15: ...se contact your dealer or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual techn...

Page 16: ...Consumer Service will still be there after your warranty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualifie...

Reviews: