![background image](http://html.mh-extra.com/html/ge/acb-ajcs-12-dcb/acb-ajcs-12-dcb_technical-service-manual_121993009.webp)
7
4. Remove 4 Phillips head screws that
mount plastic housing sides to coil hous-
ing.
BLOWER AND FAN SERVICE (Cont’d.)
5. Remove 4 Phillips head screws that
mount coil housing to bracket.
4. Remove 4 Phillips head screws that
mount motor to fan bracket.
REMOVE SIDES
REMOVE COIL HOUSING
REMOVE OUTSIDE FAN BLADE
OUTSIDE FAN
MOTOR
5/16” NUT
NOTE: In order to service inside blower/outside
fan and motors, you will have to disassemble to
this point. Both blower/fan are mounted with a
5/16” nut.
INSIDE FAN MOTOR