GE 600-1064-95R b Installation Manual Download Page 11

 

Simon XTi Installation Guide 

11 

Function Default 

setting 

Required 

setting 

Duress/panic code 

Disabled 

Disabled   

Cross zone 

Disabled 

Disabled for zones with 
high probability of false 
alarms  

Table 9 below describes nonprogrammable (hard-coded) system 
operation, as required to meet ANSI-SIA CP-01. 

Table 9: Nonprogrammable system operation   

Function Operation 

Silent exit 

All annunciators enabled 

Remote arming exit time and 
progress annunciation 

All annunciators enabled 

Abort annunciation 

Enabled 

Cancel report annunciation 

Enabled 

Recent closing 

Enabled (2-minute window) 

Exit error 

Enabled 

Restoration of power 

Panel resumes operation in same 
arming state and disregards alarm 
signals from sensors for the first 60 
seconds after power restoration 

Cancel alarm 

Enter code only 

Central station reporting 

Note

: The panel shall not be set or programmed to place a call to 

a police station number that has not been specifically assigned by 
that police station for such service. 

Caution: 

If call waiting is used on a non-call waiting line, 

successful connection to the central station may be prevented. 

The panel has been tested with the following central station 
receivers using SIA and Contact ID reporting formats: 

Before beginning installation, installers must verify that the central 
station is equipped with the following receivers: 

• 

Radionics D6600 central station receiver 

• 

Sur-Gard central station receiver with models SG-DRL2A and 
SG-CPM2 

• 

CS5000 digital alarm communicator receiver 

UL Canada listed installations 

This section describes the requirements for CUL (UL Canada) listed 
installations. 

Canadian standards CSA certified accessories: 

• 

Standard Class 2, 9 VAC, 30 VA power transformer (UTC Fire & 
Security model 22-153-CN) or Standard Class 2, 9 VAC, 25 VA, 
(UTC Fire & Security model 22-155-CN). 

Residential burglary alarm system unit (ORD-C1023-1974): basic 
system as described for UL 1023 listed installations plus: 

• 

Hardwired magnetic contact (1038T) or wireless learn mode 
door/window sensor (60-670) 

• 

Siren timeout set to six minutes or more 

Residential fire warning system control unit (ULC-S545-M89): basic 
system as described for UL 985 listed installations plus: 

• 

Wireless smoke sensor 60-848-02-95, TX-6010-01-1 learned 
into sensor group 26 

• 

Siren timeout set to six minutes or more 

FCC compliance 

This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to Part 15 of the FCC 
rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a 
residential environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful 
interference to radio communications. 

Changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to 
operate the equipment. 

FCC Part 15 registration number: B4Z-910C-SIMON 
IC: 1175C-910CSIMO 
This Class B digital apparatus complies with Canadian ICES-001. 
Cet appareil numérique de la classe B est conforme à la norme 
NMB-003 du Canada. 

Part 68. This equipment complies with Part 68 of the FCC rules and 
the requirements adopted by ACTA. 

FCC registration number: US: B4ZAK02B55910 

Canada: 1175C-910CSIXT 
Ranger Equivalence 0.2B 
Load Number 0.2

 

Summary of Contents for 600-1064-95R b

Page 1: ...62N 10 319 5 10 Interior door 60 362N 10 319 5 14 Door Window sensor 60 362N 10 319 5 13 Smoke sensor TX 6010 01 1 c 26 Glassbreak sensor 60 873 95b 13 Device Part number Recommended sensor group 4 Bu...

Page 2: ...ecure the mounting screws provided to the locations on the wall marked in step 6 Do not tighten the screws Leave enough clearance to mount the mounting plate Note Use wall anchors if no studs are pres...

Page 3: ...he use of multiple devices on a single phone line simultaneously For DSL environments connect the panel line in jack to an available phone jack on the premises You might also need an inline filter to...

Page 4: ...et is not controlled by a switch or that it is not part of a ground fault circuit interrupt GFCI Note For Canadian installations plug the transformer into the wall outlet 1 Remove the center screw fro...

Page 5: ...es that you need to close the front door Correct the problem as indicated or press Bypass You will see the arming countdown message at the bottom of the screen You can touch Cancel and enter your code...

Page 6: ...ions Opening report Closing report Force armed report AC power failure report Panel low battery report Sensor alarm restoral report 24 hour sensor tamper Supervisory tamper report No usage report Swin...

Page 7: ...o six digits long Sensors These instructions describe how to add learn sensors touchpads and other system devices into panel memory The panel recognizes a sensor when you press a sensor program icon p...

Page 8: ...ted and whenever a sensor related problem occurs Note While the sensor test is a valuable installation and service tool it only tests sensor operation for the current conditions You should perform a s...

Page 9: ...good sensor functions contact UTC Fire Security for repair or replacement of the problem sensor Sensor Testing Notes Conduct sensor test in all possible environmental conditions For example interior d...

Page 10: ...s turned on Auto arm set to on Siren timeout set to 5 minutes or more Trouble beeps set to on RF jam detect set to on Hardwired siren supervision set to on Exit extension set to off Quick exit set to...

Page 11: ...UL Canada listed installations Canadian standards CSA certified accessories Standard Class 2 9 VAC 30 VA power transformer UTC Fire Security model 22 153 CN or Standard Class 2 9 VAC 25 VA UTC Fire Se...

Reviews: