Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions

 

4. Reattach the keypad to the mounting plate.

Testing the Keypad After Mounting

Note 

While the sensor test is a 

valuable installation and ser-

vice tool, it only tests sensor 

operation for the current 

conditions. You should per-

form a sensor test after any 

change in environment, 

equipment, or programming.

Repeat the steps listed in the “Performing a Sensor Test” section in this manual.

Keypad Operation

• Numeric Buttons (0 - 9) - Used to enter an access code or turn individual lights on and off.
• Disarm Button - The control panel is disarmed to level 0 or 1. (Level 0 all sensors except 

smoke alarms are disarmed. Level 1 doors, windows, and motion sensors are disarmed). Dis-

arm also requires the access code to be entered.

• ARM Doors & Windows Button - The control panel is armed to level 2.
• ARM Motion Sensors Button - The control panel is armed to level 3. If the ARM Doors & 

Windows button was previously pressed, the control panel is armed to level 4 (Doors/Win-

dows and Motion Sensors armed).

• Lights On Button - Pressing this button twice quickly turns on all lights controlled by the sys-

tem. Pressing this button once plus 1-8 will turn on that individual numbered light.

• Lights Off Button - Pressing this button twice quickly turns off all lights controlled by the sys-

tem. Pressing this button once plus 1-8 will turn off that individual numbered light.

• Emergency Buttons - The panel will react according to the sensor group they are learned in to 

(00-07) Intrusion, Silent or Emergency. Press and hold both keys OR press both keys twice 

quickly, to activate alarm reports to the central station.

Battery Replacement

When the batteries get low on the keypad, the keypad announces “Touchpad low battery”. The 

panel announces “<Sensor name> low battery”.

Note 

Avoid pressing the buttons 

on the keypad during battery 

replacement.

Remove the touchpad from the mounting plate and replace all three batteries with AAA alkaline 

batteries.
After replacing the batteries, run a sensor test to realign the keypad to the panel.

Specifications

Compatibility:

..........................Simon 3 (version 3.3 and later)

Power Requirements:

..............3 AAA Alkaline batteries

Storage Temperature:

..............-40° to 140° F (-34° to 60° C) 

Operating Temperature:

.........32° to 120° F (0° to 49° C)

Maximum Humidity:

...............90% relative humidity, non-condensing

Dimensions:

..............................3.6 x 1.2 x 5.4 in. (W x D x H)

Installation:

..............................Wall mounting

Listings:

FCC Notice

7KLVGHYLFHFRPSOLHVZLWK)&&5XOHV3DUWV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV

1.

This device may not cause harmful interference.

2.

This device must accept any interference that may be received, including interference that may cause undesired 
operation.

&KDQJHVRUPRGLILFDWLRQVQRWH[SUHVVO\DSSURYHGE\*(6HFXULW\FDQYRLGWKHXVHU·VDXWKRULW\WRRSHUDWHWKHHTXLSPHQW
)&&,'%=7:73

Notices

5HG)R[5RDG

$UGHQ+LOOV01

7HFKQLFDO6XSSRUW

)

‹*(6HFXULW\/HDUQ0RGHLVDWUDGHPDUNRI*(6HFXULW\6LPRQLVDUHJLVWHUHG

WUDGHPDUNRI*(6HFXULW\$OORWKHUWUDGHPDUNVDUHSURSHUWLHVRIWKHLURZQHUV

$OOULJKWVUHVHUYHG

*(6HFXULW\

Summary of Contents for 60-924-3-01 - ITI Simon 3 Wireless Touch Talk Keypad

Page 1: ...anels version 3 3 and newer In chime mode all voice feedback that is heard in key mode plus trouble beeps entry exit beeps and alarm sounds Fire Aux Police are heard at the keypad The keypad will also respond to panel broadcast messages at multiple keypads While in chime mode the keypad can be supervised and will send supervision messages to the panel In chime mode the keypad is compatible with Si...

Page 2: ... programmed into the panel To program the keypad into panel memory 1 Open the control panel cover 2 Enter Utility Access Code 1 or 2 using the red numbered keys 3 Press Add The panel announces Select from Main Menu 4 Press Sensor Remote The panel announces Press button on sensor Note If the keypad doesn t announce OK press Can cel at the panel and repeat process starting from Step 3 5 Press the Li...

Page 3: ...faulty keypad Two or three beeps from the RF Sniffer indicates the keypad is functional but may have to be relocated If the keypad is faulty replace it How to Improve Sensor Communication Relocate the keypad If necessary replace the keypad To Relocate a Keypad 1 Test the keypad a few inches from the original position 2 Increase the distance from the original position Retest until an acceptable loc...

Page 4: ...mbered light Emergency Buttons The panel will react according to the sensor group they are learned in to 00 07 Intrusion Silent or Emergency Press and hold both keys OR press both keys twice quickly to activate alarm reports to the central station Battery Replacement When the batteries get low on the keypad the keypad announces Touchpad low battery The panel announces Sensor name low battery Note ...

Reviews: