background image

3

Dialog QS1500 Touchtalk Interactive Keypad Installation Instructions

 

4. Press 

Test

.

The panel responds with 

Sensor test, press again to change or DONE to select.

5. Press 

DONE

.

Note 

To verify the communication 

between the panel and the 

keypad, close the panel’s 

cover to put the panel in run 

mode. Press the SYSTEM 

STATUS button on the key-

pad. The keypad should 

announce the correct sys-

tem status (i.e. “System Dis-

armed”).

The panel will prompt you to trip each sensor one at a time. To trip the keypad, press and hold the 

two Emergency buttons simultaneously for three seconds. You may follow the panel voice 

prompting or test the sensors in any order. Use the “Sensor Tripping Instructions” table in your 

Simon 3 Installation Manual to trip sensors.
We recommend that you test the keypad after all programming is completed and whenever a key-

pad-related problem occurs.

If a Keypad Fails a Sensor Test

If panel sirens do not beep when a keypad is tripped, use a GE Security RF Sniffer (60-401) test 

tool to verify that the keypad is transmitting. Constant beeps from the RF Sniffer indicate a run-

away (faulty) keypad. Two or three beeps from the RF Sniffer indicates the keypad is functional, 

but may have to be relocated. If the keypad is faulty, replace it.

How to Improve Sensor Communication

• Relocate the keypad.
• If necessary, replace the keypad.

¾

To Relocate a Keypad:

1. Test the keypad a few inches from the original position.
2. Increase the distance from the original position. Retest until an acceptable location is found.
3. Mount the keypad in the new location (see 

Mounting the Keypad

 section).

4. If no location is acceptable, replace the keypad.

¾

To Replace a Keypad:

1. Test a known good keypad at the same location.
2. If transmission beeps remain below the minimum level, avoid mounting a keypad at the loca-

tion.

3. If the replacement keypad functions, contact GE Security for repair or replacement of the 

problem keypad.

Mounting the Keypad

To mount the keypad on a wall, do the following:
1. Open the door of the keypad.
2. Gently pull down on the tab at the bottom of the keypad to separate the keypad body from the 

keypad mounting plate (Figure 1).

3. Hold the keypad mounting plate against the wall. Using the two screws included with the key-

pad, attach the keypad mounting plate to the wall through the mounting holes (Figure 2).

Figure 1. Keypad Bottom View

Figure 2. Keypad Mounting Plate

Mounting Holes

Tab

Summary of Contents for 60-924-3-01 - ITI Simon 3 Wireless Touch Talk Keypad

Page 1: ...anels version 3 3 and newer In chime mode all voice feedback that is heard in key mode plus trouble beeps entry exit beeps and alarm sounds Fire Aux Police are heard at the keypad The keypad will also respond to panel broadcast messages at multiple keypads While in chime mode the keypad can be supervised and will send supervision messages to the panel In chime mode the keypad is compatible with Si...

Page 2: ... programmed into the panel To program the keypad into panel memory 1 Open the control panel cover 2 Enter Utility Access Code 1 or 2 using the red numbered keys 3 Press Add The panel announces Select from Main Menu 4 Press Sensor Remote The panel announces Press button on sensor Note If the keypad doesn t announce OK press Can cel at the panel and repeat process starting from Step 3 5 Press the Li...

Page 3: ...faulty keypad Two or three beeps from the RF Sniffer indicates the keypad is functional but may have to be relocated If the keypad is faulty replace it How to Improve Sensor Communication Relocate the keypad If necessary replace the keypad To Relocate a Keypad 1 Test the keypad a few inches from the original position 2 Increase the distance from the original position Retest until an acceptable loc...

Page 4: ...mbered light Emergency Buttons The panel will react according to the sensor group they are learned in to 00 07 Intrusion Silent or Emergency Press and hold both keys OR press both keys twice quickly to activate alarm reports to the central station Battery Replacement When the batteries get low on the keypad the keypad announces Touchpad low battery The panel announces Sensor name low battery Note ...

Reviews: