![GE 60-806-95R-16Z - Security Concord Express System Control... Installation Instructions Manual Download Page 61](http://html1.mh-extra.com/html/ge/60-806-95r-16z-security-concord-express-system-control/60-806-95r-16z-security-concord-express-system-control_installation-instructions-manual_4006173061.webp)
Appendix A: System Configuration Worksheets
56
08
Special Intrusion
Special belongings, such as gun cabinets
and wall safes.
Police
Instant
√
√
√
1, 2, 3
09
Special Intrusion
Special belongings, such as gun cabinets
and wall safes.
Police
Standard
√
√
√
1, 2, 3
10
Entry/Exit Delay
Entry and exit doors that require a standard
delay time. #
Police
Standard
√
√
√ √
2, 3
11
Entry/Exit Delay
Garage doors and entrances that require an
extended delay time. * #
Police
Extended
√
√
√ √
2, 3
12
Entry/Exit Delay
Driveway gates and entrances that require a
twice extended delay time. * #
Police
Twice
Extended
√
√
√ √
2, 3
13
Instant Perimeter
Exterior doors and windows. #
Police
Instant
√
√
√ √
2, 3
14
Instant Interior
Interior doors. #
Police
Follower
√
√
√
2, 3
15
Instant Interior
Interior PIR motion sensors. * #
Police
Follower
√
√
2, 3
16
Instant Interior
Interior doors. #
Police
Follower
√
√
√
3
17
Instant Interior
PIR motion sensors. * #
Police
Follower
√
√
3
18
Instant Interior
PIR motion sensors subject to false alarms. *
†
#
Police
Follower
√
√
3
19
Delayed Interior
Interior doors that initiate a delay before
going into alarm. * #
Police
Standard
√
√
√
3
20
Delayed Interior
PIR motion sensors that initiate a delay
before going into alarm. * #
Police
Standard
√
√
3
21
Local Instant Interior
24-hour local alarm zone protecting anything
that opens and closes.
Police
Instant
√
√
1, 2, 3
22
Local Delayed Interior Same as group 21, plus activation initiates a
delay before going into alarm.
Police
Standard
√
√
1, 2, 3
23
Local Instant Auxiliary 24-hour local alarm zone protecting anything
that opens and closes. ‡
Auxiliary
Instant
√
√
1, 2, 3
24
Local Instant Auxiliary 24-hour local alarm zone protecting anything
that opens and closes. Sirens shut off at
restoral. *
Auxiliary
Instant
√
√
1, 2, 3
25
Local Special Chime
Notify the user when a door is opened.
Sounds emit from a local annunciator. *
Special
Chime
Instant
√
1, 2, 3
26
Fire
24-hour fire, rate-of-rise heat, and smoke
sensors.
§
Fire
Instant
√
√
√
1, 2, 3
27
Output Module
Hardwire Output Module (HOM) lamp control
or other customer feature. ‡
Silent
Instant
√
√
1, 2, 3
28
Output Module
HOM, PIR motion sensor, sound sensor, or
pressure mat. ‡
Silent
Instant
√
1, 2, 3
29
Auxiliary
Freeze sensor.
Auxiliary
Instant
√
√
√
1, 2, 3
32
Output Module
HOM, PIR motion sensor, sound sensor, or
pressure mat. ‡
Silent
Instant
1, 2, 3
34
Gas
Carbon monoxide (CO) Gas Detectors ‡
Auxiliary
Instant
√
√
√
1, 2, 3
35
Local Instant Police
(Day Zone)
Local alarm in levels 1 and 2.
Reports to CS in level 3.
Police
Instant
√
√
√
(level
3
only)
1, 2, 3
Table A3: Sensor Group Characteristics (Continued)
No.
Name
Application
Alarm
Delay
R
esto
ral
Su
pervi
s
ory
CS Re
p
o
rt
Ch
im
e
Active
Levels