GE 60-806-95R-16Z - Security Concord Express System Control... Installation Instructions Manual Download Page 36

Programming the Panel

31

Touchpad Options Menu

The 

TOUCHPAD OPTIONS

 

menu lets you set up touchpad panic and arming operation. The fol-

lowing describes how to program the touchpad option settings that appear under 

PARTITION 1

.

Entry Delay (0310)

Timers-Partition 1 (Default=30 sec.)

This setting determines how much time (30-240 seconds) users have to disarm 
the system (after entering the armed premises through a designated delay 
door) to avoid causing an alarm.

Note  

For UL Listed residential installations, the Entry Delay must be set to 45 seconds or 
less. The combined time for the Entry Delay and Dialer Abort Delay (02006) must 
not exceed 60 seconds.

¾

To set the Entry Delay:

1. With the display showing 

ENTRY DELAY nnn 

SECONDS

 (current setting)

, enter the desired 

time value (30-240 using 8-second inter-
vals). The display flashes the entered set-
ting. 

2. Press 

ƒ

 and the display shows the new set-

ting.

Exit Delay (0311)

Timers-Partition 1 (Default=60 sec.)

This setting determines how much time (45-184 seconds) the user has to leave 
the premises through a designated delay door (after arming the system) with-
out causing an alarm.

Note  

For UL Listed residential installations, the Exit Delay must be set to 60 seconds or 
less.

¾

To set the Exit Delay:

1. With the display showing 

EXIT DELAY nnn 

SECONDS 

(current setting), 

enter the desired 

time value (45-184 using 8-second inter-
vals). The display flashes the entered set-
ting. 

2. Press 

ƒ

 and the display shows the new set-

ting.

Extended Delay (0312)

Timers-Partition 1 (Default=4 min.)

This setting determines how much time (1-8 minutes) the user has to enter or 
exit the premises through a designated extended delay door without causing 
an alarm.

Note  

For UL Listed systems, Extended Delay shall not be used.

¾

To set the Extended Delay:

1. With the display showing 

EXTENDED DELAY 

nn MINUTES

 (current setting)

, enter the 

desired time value (1-8). The display flashes 
the entered setting. 

2. Press 

ƒ

 and the display shows the new set-

ting.

Siren Timeout (0313)

Timers-Partition 1 (Default=4 min.)

This setting determines how long sirens sound (1-30 minutes) if no one is 
present to disarm the system.

Note  

For UL Listed systems, Siren Timeout must be set to 4 minutes or more.

¾

To set the Siren Timeout:

1. With the display showing 

SIREN TIMEOUT nn 

MINUTES

 (current setting)

, enter the desired 

time value (1-30). The display flashes the 
entered setting. 

2. Press 

ƒ

 and the display shows the new set-

ting.

Fire Panic (0400)

Touchpad Options-Partition 1 (Default=on)

This setting determines whether touchpad fire panic buttons are enabled (on) 
or disabled (off).

¾

To change the Fire Panic setting:

1. With the display showing 

FIRE PANIC OFF/

ON

 (current setting)

, press 

1

 (off) or 

2

 (on). 

The display flashes the entered setting. 

2. Press 

ƒ

 and the display shows the new set-

ting.

Summary of Contents for 60-806-95R-16Z - Security Concord Express System Control...

Page 1: ...h d e l a y d o o r 2 3 1 P r e s s 2 C O D E C l o s e a l l p r o t e c t e d d o o r s a n d w i n d o w s P r e s s 4 t o a r m d e l a y d o o r s i n s t a n t l y A r m t o A W A Y Z o n e S e...

Page 2: ...mpliant See the Installation Instructions for details Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation It must be able to do this even if oth...

Page 3: ...unication Le mat riel doit galement etre install en suivant une m thod accept e de raccordement Dans certains cas les fils int rieurs de l enterprise utilis s pour un service individuel a ligne unique...

Page 4: ...12 Connecting Siren Drivers Self Contained Sirens and Bells 13 Connecting Touchpads 14 Installing an RJ 31X Phone Jack 13 081 14 Connecting the Phone Line to the Panel with a DB 8 Cord 15 Connecting...

Page 5: ...lay LCD Touchpad Chime and Trouble Beep Tones 49 Troubleshooting 50 Appendix A System Configuration Worksheets 54 Cross Zoning 57 Appendix B Programming Mode Menus and Settings 66 Specifications 68 Wi...

Page 6: ...y 12 VDC 4 AH 60 681 SuperBus 2000 2x16 LCD Touchpad 60 746 01 SuperBus 2000 Fixed Display Touchpad 60 820 SuperBus 2000 2x20 LCD Touchpad 60 803 or SuperBus 2000 2x20 VFD Touchpad 60 804 Standard Cla...

Page 7: ...ts The following table describes programming requirements to meet ANSI SIA CP 01 The following table describes non programmable hard coded system operation as required to meet ANSI SIA CP 01 and is pr...

Page 8: ...to power the panel Residential Burglary Alarm System Unit CAN ULC S309 Same as UL Basic System and Household Burglary Alarm System Unit UL 1023 described previously and siren timeout must be set to 5...

Page 9: ...not installer or dealer programming Displays system messages and indi cates system status SnapCard The following SnapCards expand the system as described 8Z Input SnapCard Provides eight additional ha...

Page 10: ...by a nonconductive barrier OR B Class 2 Class 3 and power limited fire alarm cir cuit conductors must be installed as Class 1 or higher circuits Table 1 describes panel voltage current output ranges...

Page 11: ...ting Holes 5 Install anchors where studs are not present 6 Partially insert screws into the two top mounting hole locations then hang the panel on the two screws 7 Recheck for levelness insert the two...

Page 12: ...es and making wiring connections familiarize yourself with the main components of the panel Figure 4 shows the main component locations on the circuit board Figure 4 Main Component Locations Connectin...

Page 13: ...lace with two screws included with the card Figure 6 Connect all necessary input output wiring using the installation instructions included with the SnapCard Figure 6 Installing a SnapCard Note Use of...

Page 14: ...Devices Figure 8 shows the typical wiring for N C and N O door window intrusion detection Figure 8 Connecting N C and N O Intrusion Detection Circuits Figure 9 shows the typical wiring for Optex mode...

Page 15: ...t up for 2 wire smoke detectors zone 6 can handle up to 10 smoke detectors with 120 A maximum idle current per detector Maximum total loop current allowed in an alarm condi tion is 80 mA The maximum l...

Page 16: ...01500 For more information on output configuration numbers see the section Programming the Panel and the tables in Appendix A Use only 4 wire smoke detectors that operate on 8 5 to 14 2 VDC Note The...

Page 17: ...terminal 7 OUT1 12V is a 12V programmable output At the default configuration setting 00410 this output can provide up to 1 25 A during an alarm 650 mA for UL Listed systems if the backup battery is...

Page 18: ...stead of panel ter minal 4 the supply voltage must be limited to 9 5 VDC maximum and the negative side of the power supply must be connected to panel ground terminal 3 Figure 14 Connecting an Interior...

Page 19: ...PBX phone line These systems are designed only for digital type devices that operate any where from 5 volts DC and up The panel uses an ana log modem and does not have a digital converter adapter or i...

Page 20: ...e corrections where neces sary Proceed to the Troubleshooting section of this manual if problems persist Connecting the Phone Line to the Panel with a DB 8 Cord After installing the RJ 31X jack you ar...

Page 21: ...steps described in the following section Power Up the Panel Figure 18 Connecting the Power Transformer Powering Up the Panel Note Without AC power shut down will occur if battery voltage falls below...

Page 22: ...dealer code default 4321 The system can be put into program mode only when it is disarmed To enter programming mode using an alphanumeric touchpad connected to the panel terminals 1 Make sure the syst...

Page 23: ...pertain to that menu Only when a specific menu is displayed can you advance to those settings For example pressing from the SENSORS menu gives you access to learning sensors programming sensor text de...

Page 24: ...R Zone 4 hardwire Group 01 Panic Zone 5 wireless Group 01 Keychain Touchpad Zone 6 wireless Group 13 Kitchen Window COMM FAILURE off Entry Delay 8 seconds Exit Delay 8 seconds Extended Delay 1 minute...

Page 25: ...de 0000 Security Global Default 12345 The 5 digit downloader code is used in conjunction with downloader pro gramming The down loader operator must have the panel account number and downloader code in...

Page 26: ...ys Silent feature is disabled for users if this setting is on OR can be controlled by users if the setting is off Silent Arming on Demand is not affected To turn SIA False Alarm Reduction off or on 1...

Page 27: ...remises for a forgotten item When Exit Extension is on the panel restarts the exit delay timer if the user reenters the premises through a designated delay door before the exit delay time expires When...

Page 28: ...lts in false alarms due to code entry errors If a duress code is absolutely necessary use it with an Interrogator audio verification mod ule AVM to reduce false alarms and accidental dispatches Note T...

Page 29: ...2 on The display flashes the entered setting 2 Press and the display shows the new set ting Open Close Rpts 0103 cs phone 1 0113 cs phone 2 Phones CS Phone 1 2 Default off When this setting is on the...

Page 30: ...er enter the desired pager phone number including pauses The dis play flashes the entered number 2 Press and the display shows the new number To delete a Pager Phone Number 1 With the display showing...

Page 31: ...1 off or 2 on The display flashes the entered setting 2 Press and the display shows the new set ting Streamlining 0125 pager 1 0135 pager 2 0145 pager 3 Phones Pager Phone 1 3 Default on This setting...

Page 32: ...l phone test Thus any successful panel report to the central monitoring station resets the Next Phone Test setting to the Phone Test Freq value The panel only conducts an Auto Phone Test if no other r...

Page 33: ...lay shows the new set ting Cancel Message 02007 Phones Options Global Default on This setting determines whether or not the panel displays a cancel message after the user disarms the system to clear a...

Page 34: ...G HANG RING OFF ON current setting press 1 off or 2 on The display begins flashing the entered selection 2 Press and the display shows the new set ting Supervisory Time 0300 Timers Global Default rand...

Page 35: ...mber of days 1 255 The display flashes the entered setting 2 Press and the display shows the new set ting Output Trip Time 0304 Timers Global Default 4 sec This setting determines how long onboard and...

Page 36: ...nnn SECONDS current setting enter the desired time value 45 184 using 8 second inter vals The display flashes the entered set ting 2 Press and the display shows the new set ting Extended Delay 0312 T...

Page 37: ...e system When set to ON pressing the LOCK button arms the system directly to AWAY with no Entry and Exit Delay When set to OFF pressing the LOCK button increments the arming level from OFF to STAY and...

Page 38: ...station or a pager whenever sensors or zones are bypassed To turn Bypass Reports off or on 1 With the display showing BYPASS REPORTS OFF ON current setting press 1 off or 2 on The display flashes the...

Page 39: ...nsor trip does not occur within a 4 minute time period then the panel sends an error report to the central monitor ing station When this feature is turned off the panel does not send Two Trip Error re...

Page 40: ...el reports to the central monitoring station or pager daily or weekly when the panel detects a wireless device supervisory condition To set RF Supv Report to daily or weekly 1 With the display showing...

Page 41: ...sends a recent closing report to the central station or a pager if an alarm occurs within two minutes after the exit delay time expires Such a report is used to identify a possible exit fault To turn...

Page 42: ...le A 3 Sensor Group Characteristics Note For UL Listed systems Alarm Verify must be turned off To turn Alarm Verify off or on 1 With the display showing ALARM VERIFY OFF ON current setting press 1 off...

Page 43: ...te For UL Listed systems this feature must be off To turn Disable Trouble Beeps off or on 1 With the display showing DISABLE TR BEEPS OFF ON current setting press 1 off or 2 on The display flashes the...

Page 44: ...il the LED flashes two times c Press and hold the UNLOCK button until the LED flashes once 6 Continue tripping sensors to learn them into the selected sensor group To stop learning sen sors into a gro...

Page 45: ...mber P1 partition 1 G13 sensor group 13 NC normally closed HW hardwired and BACK DOOR is the programmed text name You can also change the zone sensor group assignment to eliminate the need to delete a...

Page 46: ...ction Press and the display shows the new setting Key Beeps Acc Modules Bus Devices Default on This setting determines whether or not selected touchpads sound beeps when their buttons are pressed This...

Page 47: ...d num ber Press and the display shows the new setting Note For California State Fire Marshall Listed installations this feature must be off Two Wire Smoke 0901 Onboard Options Inputs Default off This...

Page 48: ...tant Each security access code Installer Dealer System Master or User must be unique Do not use the same combination of numbers for any two codes The USER CODES menu lets you program change regular us...

Page 49: ...irect Bypassing 10nn1 nn user 00 thru 15 User Codes Default off User Codes perform basic arm ing and disarming functions The system allows up to 16 user codes user numbers 00 15 User numbers that show...

Page 50: ...y flashes the entered selection Press and the display shows the new setting Silent Arming 21 Options Default off This setting determines whether the partition arms the system with off or without on so...

Page 51: ...ic System Commands Testing Zones Sensors Testing Phone Communication Testing Central Station Pager Communication You should test the system after installing or servicing and after adding or removing d...

Page 52: ...ireless Sensor Does Not Test 4 Press the STATUS button when you think all zones sensors are tested The touchpad displays any untested sensors zones and touchpad panics If all sensors zones and touchpa...

Page 53: ...when displayed depending on pager service Account numbers are not displayed if Streamlining is turned on 1 Call the central station and tell the operator that you will be testing the system 2 Arm the...

Page 54: ...ch 3 When the desired pitch is heard release the button If there is no touchpad activity for about 15 seconds the steady tone stops sounding Table 5 Pager System Event Codes Code System Event 009 Zone...

Page 55: ...ng see the user programming OPTIONS menu Touchpad buttons don t beep when pressed 1 Check for touchpad power and or bus miswiring opens or shorts 2 Check that key beeps option is set to on see the ACC...

Page 56: ...wire Zones System doesn t go into alarm when zone is tripped 1 System is disarmed Arm system and then trip the zone 2 Zone is not learned into panel memory Enter installer dealer program mode and use...

Page 57: ...om backup battery 1 Check the AC circuit breaker to be sure the circuit is live 2 Check for proper panel and transformer wiring 3 Check that the transformer is plugged into a nonswitched outlet and se...

Page 58: ...niffer 60 401 to verify that sensor is transmitting If sensor is not transmit ting check battery for low or no voltage and replace 2 Change mounting position of sensor from horizontal to vertical or v...

Page 59: ...BXT na 1 2 mA for 10 detectors Panel limited to 100 mA 13 463 Visus LP60 PIR Motion Detector 10 mA 10 mA 13 464 DS940 PIR Motion Detector 17 mA 17 mA 13 468 Optex RX 040 PI PIR Motion Detector 17 mA 1...

Page 60: ...e emergency buttons Police Instant 1 2 3 02 Fixed Panic 24 hour silent fixed emergency buttons Silent Instant 1 2 3 03 Portable Panic 24 hour silent portable emergency buttons Silent Instant 1 2 3 04...

Page 61: ...l Instant Interior 24 hour local alarm zone protecting anything that opens and closes Police Instant 1 2 3 22 Local Delayed Interior Same as group 21 plus activation initiates a delay before going int...

Page 62: ...plication Alarm Delay Restoral Supervisory CS Report Chime Active Levels D i n i n g R o o m H a l l B e d r o o m B e d r o o m B e d r o o m P a t h o f P e r s o n W a l k i n g M o t i o n S e n s...

Page 63: ...4 Chime 074 Force 114 Mat 154 Screen 194 9 035 Closed 075 Foyer 115 Medical 155 Second 195 A 036 Closet 076 Freeze 116 Memory 156 Sensor 196 B 037 Closing 077 Front 117 Menu 157 Service 197 C 038 Code...

Page 64: ...___ ____________ ____________ ____________ ____________ Immediate Trouble Beeps Off 0600 Installer Code 4321 0001 Keychain TP Arming Off 0403 Keyswitch Sensor None 0015 Latchkey Reports Pagers 1 2 3 a...

Page 65: ...m Reduction 0003 Siren Timeout 4 minutes 0313 Siren Verify Off 0610 Smoke Verify Off 0900 SnapCard Output 1 01400 keychain Touchpad button activation 081000 SnapCard Output 2 00410 any audible alarm 0...

Page 66: ...ff System Tests off 10070 10071 10072 ___________ ___________ ___________ User Code 08 None Direct Bypassing off System Tests off 10080 10081 10082 ___________ ___________ ___________ User Code 09 Non...

Page 67: ...xterior Siren 016 Interior Siren 017 AVM Trip pulse 018 Table A7 Sensor Group Event Trigger Numbers Sensor Group Trigger No Group 00 in alarm 064 Group 01 in alarm 065 Group 02 in alarm 066 Group 03 i...

Page 68: ...or 05 in alarm 133 open 233 Sensor 06 in alarm 134 open 234 Sensor 07 in alarm 135 open 235 Sensor 08 in alarm 136 open 236 Sensor 09 in alarm 137 open 237 Sensor 10 in alarm 138 open 238 Sensor 11 in...

Page 69: ...rm 214 No Activity in alarm 216 Fire Panic in alarm 217 Police Panic in alarm 218 Auxiliary Panic in alarm 219 Opening Report in alarm 220 Closing Report in alarm 221 Latchkey Report in alarm 222 Dure...

Page 70: ...s siren time response times activate outputs only if sirens are active for another reason 3 If an alarm event does not necessarily require disarming no activity closing report etc out puts set up for...

Page 71: ...Rpts On Off Backup On Off 0114 0104 Reporting Format SIA CID 0115 0105 0124 Latchkey Rpts On Off 0134 Latchkey Rpts On Off 0144 Open Close Rpts On Off Open Close Rpts On Off Open Close Rpts On Off 012...

Page 72: ...to Phone Test On Off Ring Hang Ring On Off Dialer Abort On Off Pager Delay 15 secs 0 30 02000 02003 02001 02005 02008 0210 0211 B A Auto Test Reset On Off 02002 Dialer Abt Delay 30 secs 15 45 02006 B...

Page 73: ...level is NOT annunciated on exterior siren output B A B A B B B A B B Smoke Verify On Off 2 Wire Smoke On Off Sn nn Item n 0 A B Maximum of 4 bus devices 0 3 Press B to return to Security Menu A B Se...

Page 74: ...k After disarming and canceling an alarm the system now displays all the alarms that have occurred since the last disarming Downloader Eavesdrop delay for carrier detect on downloader call in is now 5...

Page 75: ...t 24 hours with no AC and specified standby load Radio Frequency 319 5 MHz Nominal Range 750 feet 305 meters typical open air Storage Temperature Range 30 to 140 F 34 to 60 C Operating Temperature Ran...

Page 76: ...U S R e d B l a c k 4 1 2 V I n t e r i o r P i e z o S i r e n 3 0 0 0 6 M a x i m u m 1 0 m A O u t p u t 2 I s O p e n C o l l e c t o r T h a t H a n d l e s U p T o 2 0 0 m A D e f a u l t C o n...

Reviews: