GE 229C4053P447-3 1 Installation Instructions Manual Download Page 6

Installation Instructions

Electrical Connections 

cont.

B

B3

Complete 4 wire
cord kit. Below are
step by step
instructions on
how to install the
kit.

B4

Remove the screws on
the terminal block with
a 1/4” nut driver or
phillips screwdriver.

Remove

3 screws

B5

B6

Remove the ground
screw using a 5/16”
nut driver, then
remove and discard
the ground strap. Do
not discard the
ground screw, you
will need it later.

B7

Install the four-wire
cord and strain
relief through the
hole in the
connection plate.

NEW CONSTRUCTION AND FOUR
WIRE CORD CONNECTION KIT

6

3 Screws

Gound 

Screw and

Ground Strap

Location

Strain 

Relief

Clamp

Connection

Plate

Knockout in center 

of connection plate

may be taken out

B8

Attach the green lead
below the junction
block with the ground
screw that was
removed earlier.

B9

Connect the red
and black leads to
the outside
terminals and the
white lead to the
center terminal.

B10 Push the cord upward (to relieve strain),

while tightening the strain relief clamp.

B11 Re-install the wire cover with the 5

screws removed earlier. Make sure the
wires do not become pinched between
the wire cover and mainback.

Wire
Cover

Three-wire connection continued on following page

Ground

Screw

Ground

Strap

Ground

Screw

Red or

Black

White

Red or

Black

Ground
(Green)

Connection

Plate

Strain

Relief

Clamp

4 wire

cord kit

Summary of Contents for 229C4053P447-3 1

Page 1: ...30 JBP35 JBP48 JBP64 JBP65 JBP66 JBP67 JBP70 JBP78 JBP79 JBP85 JB940 JB960 JB965 NOTE TO INSTALLER Be sure to leave these instructions with the consumer OWNER Keep these instructions for future refere...

Page 2: ...nstalled and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F generated by the range WARNING For personal safety...

Page 3: ...ons for future reference Note This appliance must be properly grounded if applicable Before you begin Read these instructions completely and carefully IMPORTANT Save these instructions for local inspe...

Page 4: ...range can with stand the heat up to 200 F generated by the range Allow 30 Minimum clearance between surface units and bottom of unprotected wood or metal cabinet and 15 Minimum between countertop and...

Page 5: ...ve January 1 1996 the National Electrical Code requires that new but not existing construction utilize a 4 conductor connection to an electric range When installing an electric range in new constructi...

Page 6: ...ound Screw and Ground Strap Location Strain Relief Clamp Connection Plate Knockout in center of connection plate may be taken out B8 Attach the green lead below the junction block with the ground scre...

Page 7: ...al Do not remove the ground strap Push the cord upward to relieve strain while tightening the strain relief clamp B9a Re install the wire cover with the 5 screws removed earlier Make sure the wires do...

Page 8: ...ecide whether the bracket will be installed on the right or left side of range location b If the bracket side of the range has an adjacent cabinet place the bracket against the back wall and cabinet a...

Page 9: ...range must be level for proper cooking and baking Use an adjustable wrench to adjust all four leg levelers until the range is level Continued on following page D9 Pick the Oven Door up by placing both...

Page 10: ...and or the rail is in the guide IF DRAWER IS CROOKED Lower the front of the drawer and push in until it closes Remove and replace making sure the rail is in the guide SPECIAL INSTRUCTIONS IF YOU HAVE...

Page 11: ...eck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended that the clock...

Page 12: ...12 NOTES Pub No 31 10463 229C4053P447 3...