Installation Required Clearances

A

***6"

MIN

**30" MIN

**15" MIN

*0"

*0"

See Ilustrations below for all rough-in and spacing
dimensions.
The range may be placed with 0” clearance (flush) at
the back wall and side walls of the cabinet.

MINIMUM DIMENSIONS BETWEEN
COOKTOP, WALLS, AND ABOVE THE
COOKTOP.

*

Make sure the wall covering, countertop
and cabinets around the range can with-
stand the heat (up to 200°F.) generated by
the range.

**

Allow 30” Minimum clearance between
surface units and bottom of unprotected
wood or metal cabinet, and 15” Minimum
between countertop and adjacent cabinet
bottom.

***

Recommended spacing to heat sensitive
surfaces.

7 1/2"

30"

36"

2 1/2"

Acceptable electrical
outlet area.
Orient the electrical 
receptacle so the 
length is parallel to the floor.

25"

2 1/2"

NOTE: Use a 4 foot power cord to prevent interference 
with the storage drawer. Power cords 4.5 or 6 foot long 
may have to be dressed to allow for proper drawer closing.

Summary of Contents for 229C4053P447-3 1

Page 1: ...30 JBP35 JBP48 JBP64 JBP65 JBP66 JBP67 JBP70 JBP78 JBP79 JBP85 JB940 JB960 JB965 NOTE TO INSTALLER Be sure to leave these instructions with the consumer OWNER Keep these instructions for future refere...

Page 2: ...nstalled and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up to 200 F generated by the range WARNING For personal safety...

Page 3: ...ons for future reference Note This appliance must be properly grounded if applicable Before you begin Read these instructions completely and carefully IMPORTANT Save these instructions for local inspe...

Page 4: ...range can with stand the heat up to 200 F generated by the range Allow 30 Minimum clearance between surface units and bottom of unprotected wood or metal cabinet and 15 Minimum between countertop and...

Page 5: ...ve January 1 1996 the National Electrical Code requires that new but not existing construction utilize a 4 conductor connection to an electric range When installing an electric range in new constructi...

Page 6: ...ound Screw and Ground Strap Location Strain Relief Clamp Connection Plate Knockout in center of connection plate may be taken out B8 Attach the green lead below the junction block with the ground scre...

Page 7: ...al Do not remove the ground strap Push the cord upward to relieve strain while tightening the strain relief clamp B9a Re install the wire cover with the 5 screws removed earlier Make sure the wires do...

Page 8: ...ecide whether the bracket will be installed on the right or left side of range location b If the bracket side of the range has an adjacent cabinet place the bracket against the back wall and cabinet a...

Page 9: ...range must be level for proper cooking and baking Use an adjustable wrench to adjust all four leg levelers until the range is level Continued on following page D9 Pick the Oven Door up by placing both...

Page 10: ...and or the rail is in the guide IF DRAWER IS CROOKED Lower the front of the drawer and push in until it closes Remove and replace making sure the rail is in the guide SPECIAL INSTRUCTIONS IF YOU HAVE...

Page 11: ...eck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended that the clock...

Page 12: ...12 NOTES Pub No 31 10463 229C4053P447 3...

Reviews: