GE 10000 Instruction Manual Download Page 5

Masoneilan 10000 Series Globe Valve Instruction Manual  |  2

© 2015 General Electric Company. All rights reserved.

1.  Introduction

The following instructions are designed to assist maintenance 
personnel in performing most of the maintenance required on the 
10000 Series valve.

GE has highly skilled service people around the world available 
for startup, maintenance and repair of our valves and component 
parts. In addition, a regularly scheduled training program is 
conducted to train customer service and instrumentation personnel 
in the operation, maintenance and application of our control valves  
and instruments. Arrangements for these services can be 
made through your local GE Representative. When performing 
maintenance use only GE replacement parts. Parts are obtainable 
through your local Masoneilan Representative. When ordering 
parts always include Model and Serial Number of the unit being 
repaired. These installation and maintenance instructions apply 
to all sizes and ratings of the Masoneilan 10000 Series control 
valves, regardless of the type of trim used. The model number, 
size and rating of the valve are shown on the identification 
tags located on the actuator. Refer to Figure 1 to identify 

 

valve nomenclature.

2.  Unpacking

Care must be exercised when unpacking the valve to prevent 
damage to the accessories and component parts. Should any 
problems arise, contact your GE Representative or Sales Office.

3.  Installation

The valve must be installed with the flow entering between the 
seats. In addition, the upper plug must be installed so that the larger 
of the two V-notches in the plug is oriented to face the inlet of the 
valve.

3.1   Before installing the valve in the line, clean piping and valve of 

all foreign materials, such as welding chips, scale, oil, grease or 
dirt. Gasket surfaces should be thoroughly cleaned to ensure 
leak-proof joints.

3.2   To allow for in-line inspection, maintenance and removal of 

the valve without service interruption, provide a manually 
operated stop valve on each side of the 10000 Series valve with 
a manually operated throttling valve mounted in the bypass 
line (See Figure 2).

Figure 2 

3.3   The valve must be installed so that the control substance 

will flow through the valve body in the direction indicated by 
the flow arrow located on the body or the words 

in and out 

stamped on end connections. In addition, see CAUTION above.

3.4   Where insulation of the valve body is required, do not insulate 

the valve bonnet.

4.  Air Piping

The actuator is designed to accept 1/4" NPT air supply piping. Use 
1/4" OD tubing or equivalent for all air lines. If the air line exceeds 25 
feet in length or if the valve is equipped with volume boosters, 3/8" 
tubing is preferred. All connections must be free of leaks.

Do not exceed loading pressure indicated on the warning tag 
located on the diaphragm cover. If no tag is present please consult 
the actuator instruction manual or consult the factory.

2nd

2nd

0

5th

4th

3rd

1st

1

1st

8

Control Characteristics

 

3.   Equal Percentage

6.  Quick Opening

7.   Linear

Body Series

10

87   Spring Diaphragm: 

direct, Air to close  
(fail open action)

88   Spring Diaphragm: 

reverse, Air to open  
(fail close action)

Actuator Type

(1)

Seat Type

 

2.   Down 

seating

Plug Type

 1.   Double Seat

(1) For Valve Travel > 2.5" use Actuator Model 37/38.

Figure 1

Numbering System

Summary of Contents for 10000

Page 1: ...GE Oil Gas 10000 Series Masoneilan Double Ported Globe Valve Instruction Manual GE Data Classification Public...

Page 2: ...E SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE...

Page 3: ...s Page 1 Introduction 2 2 Unpacking 2 3 Installation 2 4 Air Piping 2 5 Body Disassembly Refer to Figure 9 3 6 Maintenance Repair 3 6 1 Seat Ring Removal 3 6 2 Bushing Removal 3 6 3 Lapping Seats 3 6...

Page 4: ...Please report any errors or questions about the information in this manual to your local supplier These instructions are written specifically for the 10000 Series Control Valve and do not apply for ot...

Page 5: ...o that the larger of the two V notches in the plug is oriented to face the inlet of the valve 3 1 Before installing the valve in the line clean piping and valve of all foreign materials such as weldin...

Page 6: ...g Removal Threaded seat rings 15 and 16 are installed tightly at the point of manufacture and after years of service they are often difficult to remove To facilitate removal seat ring wrenches can be...

Page 7: ...ce bonnet 6 on the body and using body stud nuts 12 spaced equally apart fasten to the body using only slight pressure and tighten evenly Do not tighten nuts to torque specifications at this time The...

Page 8: ...his could prevent smooth operations of the valve If all compression is used up and the valve leaks new packing is required Valve must be isolated and pressure vented before performing packing box main...

Page 9: ...f the two V notches in that plug is in line with the inlet of the valve Placement of a witness mark on the stem may be helpful E Install bonnet gasket 13 bonnet 6 and loosely install body stud nuts 11...

Page 10: ...ure 10 Ref No Description 1 Plug Stem 2 Packing Flange Nut 3 Packing Flange 4 Packing Flange Stud 5 Drive Nut 6 Valve Bonnet 7 Valve Body 8 Plug Pin 9 Plug 10 Lower Flange 11 Body Stud Nut 12 Body Stu...

Page 11: ...Masoneilan 10000 Series Globe Valve Instruction Manual 8 2015 General Electric Company All rights reserved Notes...

Page 12: ...tered trademarks or trademarks of their respective owners General Electric Company All rights reserved Visit our web site www fr eps com E P S FRANCE 24 bis rue de Picpus 75012 PARIS Tel 33 0 9 83 01...

Reviews: