GE Oil & Gas
10000
Series
Masoneilan* Double Ported Globe ValveInstruction Manual
GE Data Classification : Public
Page 1: ...GE Oil Gas 10000 Series Masoneilan Double Ported Globe Valve Instruction Manual GE Data Classification Public...
Page 2: ...E SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE...
Page 3: ...s Page 1 Introduction 2 2 Unpacking 2 3 Installation 2 4 Air Piping 2 5 Body Disassembly Refer to Figure 9 3 6 Maintenance Repair 3 6 1 Seat Ring Removal 3 6 2 Bushing Removal 3 6 3 Lapping Seats 3 6...
Page 4: ...Please report any errors or questions about the information in this manual to your local supplier These instructions are written specifically for the 10000 Series Control Valve and do not apply for ot...
Page 5: ...o that the larger of the two V notches in the plug is oriented to face the inlet of the valve 3 1 Before installing the valve in the line clean piping and valve of all foreign materials such as weldin...
Page 6: ...g Removal Threaded seat rings 15 and 16 are installed tightly at the point of manufacture and after years of service they are often difficult to remove To facilitate removal seat ring wrenches can be...
Page 7: ...ce bonnet 6 on the body and using body stud nuts 12 spaced equally apart fasten to the body using only slight pressure and tighten evenly Do not tighten nuts to torque specifications at this time The...
Page 8: ...his could prevent smooth operations of the valve If all compression is used up and the valve leaks new packing is required Valve must be isolated and pressure vented before performing packing box main...
Page 9: ...f the two V notches in that plug is in line with the inlet of the valve Placement of a witness mark on the stem may be helpful E Install bonnet gasket 13 bonnet 6 and loosely install body stud nuts 11...
Page 10: ...ure 10 Ref No Description 1 Plug Stem 2 Packing Flange Nut 3 Packing Flange 4 Packing Flange Stud 5 Drive Nut 6 Valve Bonnet 7 Valve Body 8 Plug Pin 9 Plug 10 Lower Flange 11 Body Stud Nut 12 Body Stu...
Page 11: ...Masoneilan 10000 Series Globe Valve Instruction Manual 8 2015 General Electric Company All rights reserved Notes...
Page 12: ...tered trademarks or trademarks of their respective owners General Electric Company All rights reserved Visit our web site www fr eps com E P S FRANCE 24 bis rue de Picpus 75012 PARIS Tel 33 0 9 83 01...