loudspeakers
-Long-Time-Mode not active
Signal >15sec.)
-Increase the volume level of the audio
source
Audio output not complete or
chopped off
-Threshold trigger value too high
-Volume too low
-Reduce threshold trigger value (Turn
the potentiometer a little to the left)
-Increase volume of the audio source
Volume difference between the
various audio sources
-Different output levels from the
audio sources
-Adjust the output volume of the audio
sources
-Use external volume control
Bluetooth® connection not possible
/ not stable
(only in combination with
BT Link 1
or
BT Link 2
)
-BT-Module already used
-Pre-existing faulty connection
-Incorrect PIN entry
-Signal range too weak
-Only one unit can be connected for
each BT-Profile (e.g. Mobile telephone
and Audio player)
-Switch off the equipment (observe
switch off delay), after start up create
a new connection
-Enter PIN: 0000 to pair the equipment
-Reduce the range. Do not cover the
equipment with metal parts.
Noise on the Hands Free Function
-Ambient noise
-Mobile phone emitting maximum
transmit power
-Microphone placed incorrectly
-Radio, ventilation or other ambient
noise is reaching the microphone
-Mobile telephones often switch to
maximum transmit power in vehicles.
These transmissions can affect the
microphone. The distance between
the microphone and the mobile phone
must be increased.
-Place the microphone facing the
driver or reduce the distance between
the microphone and the driver.
What are the unconnected cables
on the ISO-Adapter for
External Mute, in combination with
Hands Free equipment
See Point 5/e. Page 6. If the
connection is unused, please
electrically isolate the cable end
10. Declaration of Conformity
The company ge-tectronic, declares in its sole responsibility that the Product:
FastMute
Sonic XL
to
which this declaration refers, conforms to the following standards or standardising documents:
EMV:
Emissions
EN
61000-6-3:200
Immunity EN 61000:6-1:2001
Equipment safety
EN 60335-1:2002
Complies with the guideline regulations:
89/336/EWG EMV-Directive
73/23/EWG
Low Voltage Directive
11. Options, Accessories