GE Security NetworX Series NX-8V2 Installation Instructions Manual Download Page 2

NX-8V2-Control Panel

Installation Instructions

2

Module list 

Table 3

 shows the modules that are compatible with the NX-

8V2 system. Additional information and a catalog listing all 
system components is available from GE Customer Support.

Note:  

The NX-8V2 control panel sends a trouble condition once each 

hour if it senses that no devices have been enrolled. This report 
shows expander trouble--device zero (0).

Control panel programming

Programming the control panel requires you to enter 
program mode, select the module to program, program a 
location, and then exit the location and program mode.

Enter program mode

To enter program mode, do the following:
1.

Press 

∗, 

8

. The five function LEDs (Stay, Chime, Exit, 

Bypass, and Cancel) begin flashing.

2.

Enter the go to program code (default is 

9

,

 7

,

 1

,

 3

). If the 

g

o to program code entry is valid, the Service LED 

flashes, and the five function LEDs illuminate. You are 
now in program mode and can select the module to 
program. 

Select the module to program

Since all modules connected to the NX-8V2 are programmed 
through the keypad, the module you are programming should 
be the first entry. To select the module to program, enter 

0

#

The 

0

 is the module number of the control, and 

#

 is the entry 

key. You can find other module entry numbers in the module 
documentation.

Program a location

Once you enter the module number, the Armed LED illumi-
nates, indicating the keypad is waiting for you to enter a 
programming location. To program a location, do the 
following: 
1.

To access any location, enter the desired programming 
location, followed by 

#

. If the location is a valid location, 

the Armed LED extinguishes, the Ready LED illuminates, 
and the binary data for the first segment of the location 
is shown by the Zone LEDs. 

2.

While entering new data, the Ready LED begins flashing 
to indicate a data change in process.

3.

Press 

∗ 

to store the newly entered data. The keypad 

advances to the next segment and displays its data. 
Repeat this procedure until the last segment is reached. 

4.

To move to another location after exiting a location 
(Armed LED illuminated):

• Press the 

Police

 key for the next sequential location. 

• Press the 

Fire

 key for the previous location.

• Press the 

Medical

 key for the same location.

5.

To review the data in a specific location, repeat the 
above procedure, pressing 

 but with no numeric data 

entry. Each time you press 

, the programming data of 

the next segment displays.

Exit a location

To exit the current programming location, do the following:
1.

Press the 

 key. The Ready LED goes off and the Armed 

LED goes on. You must press the 

∗ 

key to save the data.

2.

To exit before the last segment, press 

(Armed LED illu-

minates). 

You are now ready to enter another programming location. If 
you attempt to program an invalid entry for a particular 
segment, the keypad beeps three times indicating an error 
and remains in that segment awaiting a valid entry. 

Exit program mode

To exit program mode, do the following:
1.

When you have completed all programming, press 

Exit

 

to leave the selected module.

2.

If there is another module to be programmed, select it by 
entering its address, followed by 

#

. The procedure for 

programming these devices is the same as for the 
control panel, except the locations are for the module 
selected.

3.

If no additional modules are to be programmed, press 

Exit

 again to leave program mode.

Table 3.

Modules that can be added to the NX-8V2

Part

Description

NX-108E

8-zone LED keypad

NX-116E

16-zone LED keypad

NX-124E

24-zone LED keypad

NX-148E

Alphanumeric 48-zone LCD keypad

NX-148E-RF

b

Alphanumeric 48-zone LCD keypad with built-in 48-zone 

wireless receiver

NX-200 

a

a.

These products have not been tested and approved by Un-
derwriters Laboratories, In.

Zone doubling kit (includes one hundred 3.74k and one 

hundred 6.98k resistors)

NX-320E

Smart power supply and bus extender

NX-408E 

b

b.

These wireless devices are UL listed only for residential ap-
plications.

8-zone wireless expansion module
(UL listed part #60-904)

NX-416E 

b

16-zone wireless expansion module
(UL listed part #60-904)

NX-448E 

b

48-zone wireless expansion module
(UL listed part #60-904)

NX-508E

Eight-output module

NX-534E 

a

Two-way listen-in module

NX-540E 

a

Operator telephone interface module

NX-548E

b

48-zone wireless receiver

NX-591E-GSM

a

Cell interface

NX-1192E

192-zone LCD keypad

NX-1208E

8-zone LED keypad

NX-1248E

48-zone LCD keypad

NX-1308E

8-zone LED door design keypad

NX-1316E

16-zone LED door design keypad

NX-1324E

24-zone LED door design keypad

NX-1448E

48-zone fixed language icon keypad

Summary of Contents for NetworX Series NX-8V2

Page 1: ...ted in location 37 this output becomes voltage output 12 VDC 1 Amp maximum load Note A 3 3 kohm resistor may be required across the bell terminals when a 12 VDC siren is used If no resistor is used you may experience voltage leakage into the siren which will cause these devices to output a small signal KP DATA Connect to the data terminal on the keypads and the expanders Maximum number of devices ...

Page 2: ...previous location Press the Medical key for the same location 5 To review the data in a specific location repeat the above procedure pressing but with no numeric data entry Each time you press the programming data of the next segment displays Exit a location To exit the current programming location do the following 1 Press the key The Ready LED goes off and the Armed LED goes on You must press the...

Page 3: ...f numerical data Use this loca tion to program the communicator format used to transmit to the receiver connected to phone 1 Refer to your central station receiver documentation to determine which format is compatible Table 4 describes the formats for this location If you need a format other than those listed review the over ride options described in Location 18 Custom communicator format on page ...

Page 4: ... restores 2 Opening and closings 3 Zone bypass and bypass restores 4 Zone trouble and trouble restores 5 Power fail low battery power restore and low battery restore 6 Bell cut telephone line cut bell cut restore telephone line restore 7 Test reports 8 Start and end programming download complete Segment 2 1 Zone and box tamper and tamper restore 2 Auxiliary power overcurrent ground fault and resto...

Page 5: ...tomatically bypasses if enabled in segment 1 16 Instant with group bypass This zone creates an instant alarm whenever it is tripped and the armed LED is on This zone bypasses when the group bypass command is entered at the keypad 17 Entry exit delay 1 with tamper A trip starts entry delay 1 The lack of a trip during exit delay enables the automatic bypass or instant mode if programmed This zone ty...

Page 6: ...ad sounder If the late to close early to open feature is enabled the opening and closing reports must be enabled For Canadian installations the class II transformer secure tab must not be employed The four wire smoke detector employed must be rated to operate over the voltage range of 11 5 to 12 4 V Compatible listed devices special applications Bell output sirens Wheelock models NS 1215W NS 12157...

Page 7: ... based on three 17 A batteries Table 6 Use markings Model number Use marking Subassemblies NX 8 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8E S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8V2 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 508 NX 508E Res Fire1 and Burg2 Com Burg4 Acc5 Output ...

Page 8: ...structions 8 CAUTION Observe polarity when installing a new battery Installing the battery backwards may cause damage to the panel Dispose of used batteries according to the manufacturer s instructions and or local government authorities ...

Page 9: ...is feature is not programmable in the panel Exit time and progress are always enabled Enabled disabled for remote arming Entry delays b b Combined abort window time and entry delay must not exceed one minute Entry 1 delay 24 1 30 30 to 240 seconds Entry 2 delay 24 3 30 30 to 240 seconds Abort window for nonfire zones Dialer delay 40 8 30 Enabled may be disabled by zone zone type but no cancel repo...

Page 10: ... draw Without sounder Dimensions 110 mA max 75 mA 6 4 x 5 3 x 1 0 in 16 3 x 13 5 x 2 5 cm Metal enclosure dimension 11 25 x 11 25 x 3 50 in 28 58 x 28 58 x 8 90 cm Shipping weight 9 lb 4 1 kg FCC This device complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received inc...