GE Security NetworX Series NX-8V2 Installation Instructions Manual Download Page 10

NX-8V2-Control Panel

Installation Instructions

10

Specifications

 

Operating power 

16.5 VAC 40 or 50 VA transformer

Auxiliary power
     w/25 VA transformer
     w/40 or 50 VA transformer 

(MG Electronics part 

number 22-156 for US or 

22-156-CN for Canadian 

installations)

12 VDC regulated 500 mA
12 VDC regulated 1 A

Loop resistance
     Standard loop

300 ohms maximum

Fuse

Type T 200 mA 250 VAC

Built in siren driver 

Two tone (temporal and yelp)

Loop response

Selectable 50 mS or 500 mS

Operating temperature

32 to 120°F (0 to 49°C)

LED keypad
     Current draw
     Zones normal w/o sounder
     Dimensions

130 mA max.
55 mA
6.4 x 4.0 x 1.1 in. (16.3 x 10.2 x 2.8 cm)

NX148E LCD keypad
     Current draw
     Without sounder
     Dimensions

110 mA max.
75 mA
6.4 x 5.3 x 1.0 in. (16.3 x 13.5 x 2.5 cm)

Metal enclosure dimension

11.25 x 11.25 x 3.50 in. (28.58 x 28.58 x 8.90 

cm)

Shipping weight

9 lb. (4.1 kg)

FCC

This device complies with part 15 of the FCC rules. Operation is subject to the 

following conditions: 
1. This device may not cause harmful interference. 
2. This device must accept any interference received, including interference that 

may cause undesired operation. 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment. 
Complies with Part 68 FCC Rules.
ACTA (FCC) ID: GCQUSA-33408-AL-E
IC: 1175A-NXV2 

Technical support

888 GE Security (888.437.3287). Toll-free in the US, Puerto Rico, and Canada. 

503.885.5700 outside the toll-free area or contact your local dealer. 

www.gesecurity.com

  

   

 

Summary of Contents for NetworX Series NX-8V2

Page 1: ...ted in location 37 this output becomes voltage output 12 VDC 1 Amp maximum load Note A 3 3 kohm resistor may be required across the bell terminals when a 12 VDC siren is used If no resistor is used you may experience voltage leakage into the siren which will cause these devices to output a small signal KP DATA Connect to the data terminal on the keypads and the expanders Maximum number of devices ...

Page 2: ...previous location Press the Medical key for the same location 5 To review the data in a specific location repeat the above procedure pressing but with no numeric data entry Each time you press the programming data of the next segment displays Exit a location To exit the current programming location do the following 1 Press the key The Ready LED goes off and the Armed LED goes on You must press the...

Page 3: ...f numerical data Use this loca tion to program the communicator format used to transmit to the receiver connected to phone 1 Refer to your central station receiver documentation to determine which format is compatible Table 4 describes the formats for this location If you need a format other than those listed review the over ride options described in Location 18 Custom communicator format on page ...

Page 4: ... restores 2 Opening and closings 3 Zone bypass and bypass restores 4 Zone trouble and trouble restores 5 Power fail low battery power restore and low battery restore 6 Bell cut telephone line cut bell cut restore telephone line restore 7 Test reports 8 Start and end programming download complete Segment 2 1 Zone and box tamper and tamper restore 2 Auxiliary power overcurrent ground fault and resto...

Page 5: ...tomatically bypasses if enabled in segment 1 16 Instant with group bypass This zone creates an instant alarm whenever it is tripped and the armed LED is on This zone bypasses when the group bypass command is entered at the keypad 17 Entry exit delay 1 with tamper A trip starts entry delay 1 The lack of a trip during exit delay enables the automatic bypass or instant mode if programmed This zone ty...

Page 6: ...ad sounder If the late to close early to open feature is enabled the opening and closing reports must be enabled For Canadian installations the class II transformer secure tab must not be employed The four wire smoke detector employed must be rated to operate over the voltage range of 11 5 to 12 4 V Compatible listed devices special applications Bell output sirens Wheelock models NS 1215W NS 12157...

Page 7: ... based on three 17 A batteries Table 6 Use markings Model number Use marking Subassemblies NX 8 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8E S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 8V2 S Res Fire1 and Burg2 Com Burg4 Acc5 Homehealth Care Control Unit Motherboard NX 508 NX 508E Res Fire1 and Burg2 Com Burg4 Acc5 Output ...

Page 8: ...structions 8 CAUTION Observe polarity when installing a new battery Installing the battery backwards may cause damage to the panel Dispose of used batteries according to the manufacturer s instructions and or local government authorities ...

Page 9: ...is feature is not programmable in the panel Exit time and progress are always enabled Enabled disabled for remote arming Entry delays b b Combined abort window time and entry delay must not exceed one minute Entry 1 delay 24 1 30 30 to 240 seconds Entry 2 delay 24 3 30 30 to 240 seconds Abort window for nonfire zones Dialer delay 40 8 30 Enabled may be disabled by zone zone type but no cancel repo...

Page 10: ... draw Without sounder Dimensions 110 mA max 75 mA 6 4 x 5 3 x 1 0 in 16 3 x 13 5 x 2 5 cm Metal enclosure dimension 11 25 x 11 25 x 3 50 in 28 58 x 28 58 x 8 90 cm Shipping weight 9 lb 4 1 kg FCC This device complies with part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received inc...

Reviews: