Chapter 2: Installation
Led Indicators
LED Indicators
LED
Color
Function
P1
Green
Lit:
indicates the power 1 has power.
P2
Green
Lit:
indicates the power 2 has power.
FAULT
Green
Lit:
indicates the either power 1 or power 2 has no power.
1000
Green
Lit:
indicates the Switch is successfully connecting to the network at 1000Mbps.
Off:
indicates that the Switch is successfully connecting to the network at 10 or
1000Mbps.
Blink:
indicates that the Switch is actively sending or receiving data over that port
100
Green
Lit:
indicates the Switch is successfully connecting to the network at 100Mbps.
Off:
indicates that the Switch is successfully connecting to the network at 10 or
100Mbps.
Switch Upper Panel
The upper panel of the Industrial Gigabit Ethernet Switch consists of one terminal
block connector within two DC power inputs. Figure 2 shows the upper panel of the
Industrial Gigabit Ethernet Switch.
Figure 2: Industrial Gigabit Ethernet Switch Upper Panel
Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Gigabit
Ethernet Switch is used for two DC redundant powers input. Please follow the steps
below to insert the power wire.
1.
Insert positive / negative DC power wires into the contacts 1 and 2 for POWER
1, or 5 and 6 for POWER 2.
GE-DSG-8 DSGH-5 and 8 Ethernet Switch User Manual
7