1/10/2011
3.
Configure the Base as follows:
System Configuration Menu
-==========================================================================-
A) Unit Type Base
B) Base Unit Zone A
C) Window Size 2
D) ITCS UDP Receive Port 50000
E) Timing Signal Timeout 60 Seconds
F) ITCS Translation Table
Select a letter to configure an item, <ESC> for the prev menu
ITCS Translation Table Menu
-==========================================================================-
Dest Addr Addr Mask Dest IP Addr Dest Port RSSI Opt
--------------------------------------------------------------------------
A) 12345678 FFFFFFFF 10.4.147.170 53000 NO
B) New Entry
Select a letter to configure an item, <ESC> for the prev menu
Radio Configuration Menu
-==========================================================================-
A) Base Transmit Frequency 221.900000 MHz
B) Mobile Transmit Frequency 221.900000 MHz
C) Transmit Slots 4
D) Output Power 2 W
E) Force Tx Key Normal
F) TX Key Timeout 5 sec
Select a letter to configure an item, <ESC> for the prev menu
4.
Reboot the Base
5.
Obtain the Parametric Poller (parm_poller.exe) from GE MDS. This utility saves its settings
to parm_poller.ini in the current directory, so make one directory for the base and a
different directory for the mobile.