- 16 -
lamp will light;if the connection of N,L,G is wrong,then the green lamp doesn’t light,please check
the power supply.
10
High voltage output indicator lamp:This lamp is out of control of the electric circuit.If the
voltage in the high voltage output port is greater than 110V,this lamp will flash.If in the reset
state,the lamp will flash,then the high voltage output port may have high output,it is prohibited to
touch any part of the test circuit.
11
Super leakage indicator lamp This lamp is on when the test is not qualified.
12
Test indicator lamp This lamp is on when the start button is pressed.
13
Voltage display window
14
Current display window
15
Time display window:The range of time is 0.0s~999s.When the time is less than 100s,the
time resolution is 0.1s;when the time is greater than or equal to 100s,the time resolution is 1s.If the
time is set to 0.0s,then the test time to add count;when the time is not set to 0,the time to reduce
count.
16
UP button When setting the time, press this key, the time setting value will increases;
17
DOWN button When setting the time, press this key, the time setting value will decreases;
18
Current preset adjusting potentiometer:When the "test/preset"(18)button is pressed for the
current preset state,the current display window shows the preset current value,adjust clockwise the
preset current will increases;adjust anticlockwise the preset current will decreases.
19
"test/preset":button This button is pressed for the preset current state, and pop-up for the
test status.
20
2mA/20mA switch button This button is pressed for the 20mA file,pop-up for the 2mA
file.
21
AC/DC switch button This button switches the display voltage is the AC voltage or DC
voltage;the window display the DC voltage when it is pressed,the window display the AC voltage
when it is pop-up.
5.
ZX2671A