15
SOMFY ROLLIXO QUICK COMMISSIONING
Page 5
L1
L2
N
M
1
2
3
4
Bleu
Marron
Noir
Sec
Safety Edge
Stop
K
5
6
7
8
9
1
Green/Y
ellow
Brown
Blue
Black
Sec
Safety Edge
Stop
K
5
6
7
8
9
1
L1
L2
N
M
1
2
3
4
Bleu
Marron
Noir
Sec
Safety Edge
Stop
K
5
6
7
8
9
1
Green/Y
ellow
Brown
Blue
Black
Sec
Safety Edge
Stop
K
5
6
7
8
9
1
Safety brake
jjuum
mppeerr
Connect the electrical safety brake
into terminals 5 & 6.
Use the link provided to
connect terminals 5 & 6
3
4
2
1
Prog
STOP
Unfold the aerial so
that it points verti-
cally downwards.
Powering up the Rollixo RTS
Screw the bulb
supplied into the
light fitting.
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
Refit the panel
cover and secure
with the screw.
Plug in the supply cable and con-
nect the the mains supply.
3
4
2
1
Prog
STOP
Refit the
courtesy light
cover.
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
If the motor LED comes on, check the
safety brake or link connection.
If the safety edge LED comes on, the safety
edge transmitter has not been recognised.
Prog
3
4
2
1
Prog
STOP
Prog ProgProg Prog
Prog
All the LED’s
come on briefly
and then go out.
Prog
(This is normal if the safety edge transmitter has
not been paired to the Rollixo RTS yet).
OR
Rollixo Quick GuideHW_A5_02.indd 5
12-07-17 14:02
The safety brake jumper is pre-fitted to terminals
5 and 6.
Page 8
Hard wired safety edge connection
Se c
Safety Edge
Stop
KeySwitch
5
6
7
8
9
10
11
1
Brown
Brown
Brown
White
White
White
Green
Green
Green
Dipswitch 4 receiver position
Pairing Keygo RTS keyfob’s (supplied paired)
Press the ‘Prog’ button on the Rollixo RTS front panel until the LED above the Prog button
lights up RED.
Press the button on the Keygo RTS keyfob that you want to control the Rollixo RTS controller
with until the ‘Prog’ LED on the Rollixo RTS controller flashes and then goes out.
sol
sol
3
4
2
1
Prog
STOP
20 mm
max
1 2 3 4
ON
3 screws
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
sol
sol
3
4
2
1
Prog
STOP
20 mm
max
1 2 3 4
ON
3 screws
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
Rollixo Quick GuideHW_A5_02.indd 8
12-07-17 14:02
The cable connects via a
plug-in connector block,
(this comes pre-wired).
IMPORTANT! Make sure you connect the
pre-wired green terminal block before
bringing power to the control board.
Pre-wired block
Control panel
connector
Push to fit
Pre-wired block in place
Summary of Contents for ThermaRoll 55
Page 27: ...27 ...