Step 6:
Set clamping range
You can set the desired clamping range by adjusting
the adjusting screw.
To set a clamping range from Ø 3mm to Ø 12mm,
use the adjusting mandrel with the Ø 12mm.
To set a clamping range from Ø 7mm to Ø 20mm,
use the adjusting mandrel with the Ø 20mm.
(ISO 2768 -f)
Winkelmaße
- 6
>6-30
>30-120
>120-400
>400-1000
>1000
0,05
0,1
0,15
0,2
0,3
0,5
- 10
>10-50
>50-120
>120-400
>400
1°
30`
20`
10`
5`
Längenmaße
1
F
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
A
B
C
D
E
F
A
B
C
D
E
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung
und Mitteilung seines Inhalts sind verboten, soweit nicht ausdr
ücklich gestattet.
Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte fü
r den Fall der Patent-, Gebrauchsmuster- oder Geschmacksmustere
intragung vorbehalten
Backenfutter SHARK
Schutzvermerk
DIN 34 beachten
GDS
Präzisionszerspanungs GmbH
System Walter SK50
1
1
A3
1:2
Material <nicht festgelegt>
16.65
Gewicht (kg):
/
Status
Material:
Blatt / von
Benennung:
Artikelnummer:
Format
Maßstab
Rohabmessung:
DIN 6 T1 -
Proj.methode 1
AR
Name
10.05.2019
Datum
Gepr.
Erstellt
Name
Datum
Änderung
Rev
Allgemein-
toleranzen
DIN ISO 2768-mK
Zeichnungsnummer:
020.172.000Z100
Oberflächenbehandlung:
400008000
Align the concentricity by tapping on the alignment
surface with the alignment hammer (9) supplied.
1.
Turn the A-axis evenly clockwise to the highest clock
deflection value. Now reduce this by half the value by
tapping.
2.
Repeat this process until you have achieved a runout
of 0.001mm. Then tighten the mounting screws
crosswise with 15Nm.
3.
Unclamp and clamp the adjusting mandrel three to
five times so that the chuck settles and the assembly
tensions are released.
4.
Check the concentricity again. Readjust if necessary.
Step 5:
Adjust concentricity
Alignment surface
To note:
•
The SHARK multi-range clamping system was designed for loading and changing rotationally
symmetrical blanks and tools in automatic mode.
•
For shank tools, all shanks according to DIN 1835 Form A, B, E or DIN 6535 form HA, HB, HE
can be clamped.
•
The SHARK multi-range clamping system may only be used within the scope of its technical
data. within the scope of its technical data.
•
This product is intended for industrial use.
•
Intended use includes compliance with all the information in these instructions.
•
Faultless function and warranty claims can only be guaranteed with original GDS accessories.
•
Inserting the blank by hand is prohibited.
GDS
SHARK error causes and solutions
Check the following points:
•
Check clamping pressure
•
Check blank
•
Contamination
•
All mounting screws correctly tightened
•
Chuck requires room temperature
•
Open everything again, clean and start from the beginning step by step
ATTENTION:
To ensure proper functioning, disassemble
and clean the chuck at least once a month.
When adjusting, use precision dial gauges
as well as the adjusting mandrel supplied.
Setting
concentricity and repeatability
Please take the time to adjust the runout. The more accurately the chuck is set during setup, the more accurately it
will behave.