![GDS GDS 4 Installation And Maintenance Manual Download Page 4](http://html.mh-extra.com/html/gds/gds-4/gds-4_installation-and-maintenance-manual_571747004.webp)
4
2.
S
PECIFICATIONS
(subject to change without notice)
GDS 4
GD 6,7
(A
DJUSTABLE
)
(A
DJUSTABLE
)
W
EIGHT OF OPERATOR
:
38 kgs
GDS 6 = 61 kgs GDS 7 = 80.00 kgs
(
NOT INCLUDING ARMS
)
WIRING AND SUPPLY REQUIREMENTS:
240vac single phase on the Control Box side.
1 x 3 core plus earth 1.5mm 3 phase shielded motor cable to each operator.
1 x 3 core 0.5mm (min) control cable for limit switches to each operator
*
Control input cables, Output signal cables, Lock cabling
*
*
Wiring preferably to be shielded if over 8m runs and or run directly next to 240v cabling, to avoid interference
induced back to controls. Do not use twisted pair data cable as the wire is to small and brittle.
A suitably rated Isolator and 240vac single phase power supply should be available where the gate operator
control box is to be mounted.
In some cases, nuisance RCD tripping may occur, especially if more than one VSD is being connected to the same
supply circuit. If so, see below.
*To conform to latest RCD protection regulations and to reduce the chance of nuisance tripping, use a super
immune type of RCD such as in the Clipsal 4 series, or similar. If false trips still occur, the EMC circuit may have to
be de activated on the VSD, refer to VSD manual for de activation. This leakage current is inherent with VSD
operation and is usually minimal at around 3ma + or -, dependant on installation conditions, loading on motor etc.
If electrical cabling needs to be run across the driveway (for dual operators or where the single gate operator is on
the opposite side to the control box) then ensure the appropriate number of cables (see wiring requirements) are
run in conduit and are installed at the correct depths and manner for both the mains voltage cables and low voltage
cables.
M
OTOR
:
230v 180w
230v
25
0w
D
UTY CYCLE
:
100%
100%
S
PEED
:
8-12 sec/90
o
10-13 sec/90
o
Summary of Contents for GDS 4
Page 11: ...11 6 COMMISSIONING ...