GDS GDS 4 Installation And Maintenance Manual Download Page 3

3

1.

S

AFETY

P

RECAUTIONS

WARNING!

FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION INSTRUCTIONS COULD RESULT

IN INJURY OR DEATH AND

/

OR DAMAGE TO PROPERTY AND EQUIPMENT

.

Appropriately licensed and competent personnel only should install the automation equipment.

The operators are designed specifically to open and close sliding gates or doors and should not be used for any

other purpose.

Before commencing installation, read through this installation manual.

Check that the operator and controls are in new condition and have not been damaged in transit.

Check the gate or door and its associated support posts and walls to protect against shearing, compression and

other various traps which could cause serious injury or death. Take into consideration the general installation and

surrounding environment.

Check the gateposts or mounting structure has the necessary strength and rigidity to support the operator and the

load of the opening and closing gate motion.

Gate leaf`s over 2.4m in length, should have some form of electro mechanical, or magnetic locking fitted to

avoid possible damage to gearbox from forcing due to vandalism, negligence, ramming.

CAUTION!
Always incorporate the appropriate Photo Electric Cells, Induction Loops and any other safety devices to protect

both equipment and personnel. Extra caution should be employed when using operator in auto close mode.

Display any necessary signs to indicate any danger areas and automatic operation of the gate or door.

The operators are not designed to be used in any hazardous areas or areas subject to flooding etc.

All electrical connections and wiring must be performed with AS/NZS 3000-2018 as the guidelines. (Or its

counterpart for other countries outside of Australia and New Zealand)

WARNING! ELECTRICITY CAN KILL

The manufacturer of the automation equipment is not responsible for the damage which may be caused to either, the

operator, gate or door and any other person or equipment when: -

o

Wrong or poor installation practices were performed.

o

No or inadequate safety devices were used.

o

Either the surrounding structure or the gate or door strength and rigidity was not sufficient for the task in

hand.

o

Inefficient locking devices were employed.

o

Poor maintenance on the equipment.

o

Any other circumstances beyond the manufacturers control.

Isolate power before attempting any maintenance, qualified personnel only to carry out maintenance

Only original spare parts are to be used should there be a requirement for them.

Keep loose clothing and hands clear of the gate whilst in operation or potentially able to be operated.

The installer should provide all information concerning the use of the automation equipment as well as

instructions regarding the manual override and maintenance procedures to the users of the system.

Summary of Contents for GDS 4

Page 1: ...tallation and Maintenance Manual Swing Gate Operators Models GDS 4 6 7 Made in Australia from Australian quality imported components Delta VSD 10 Bennet Ave Melrose Park SA 5039 8374 3466 March 2020 V2 00 ...

Page 2: ...Electrical Connections Mode Selection Variable Speed Drive precautions for safe use and alternative power supply refer to Teco L510S quick start guide for parameter lists and settings 5 Commissioning 10 6 CB 6 control board layout 11 7 Schematic wiring diagram 12 8 Manual release instruction 13 9 Maintenance details 14 10 Warranty 15 ...

Page 3: ...d personnel Extra caution should be employed when using operator in auto close mode Display any necessary signs to indicate any danger areas and automatic operation of the gate or door The operators are not designed to be used in any hazardous areas or areas subject to flooding etc All electrical connections and wiring must be performed with AS NZS 3000 2018 as the guidelines Or its counterpart fo...

Page 4: ...s nuisance RCD tripping may occur especially if more than one VSD is being connected to the same supply circuit If so see below To conform to latest RCD protection regulations and to reduce the chance of nuisance tripping use a super immune type of RCD such as in the Clipsal 4 series or similar If false trips still occur the EMC circuit may have to be de activated on the VSD refer to VSD manual fo...

Page 5: ...ly using suitable chemical type anchors to ensure a firm mounting is obtained Fixing without mounting plate ensure spacers i e washers or nuts are used between the wall and the operator to allow for the cover to fit Lift operator into position and bolt to the mounting plate PLAN YOUR LIFT IF NO MECHANICAL AIDS ARE AVAILABLE FIND SOMEONE TO ASSIST Turn the knurled knob anticlockwise and position ar...

Page 6: ...contact and therefore should be left unconnected if not used All the switch inputs of this control board including the limit switch inputs require a switch contact only Do not connect any switches which provide a voltage to the control board as this will damage the control board If the inputs are 12 24v or has long wiring associated with it use an IM 1 module to isolate it from the control board s...

Page 7: ...ted POSITION 5 M 2 Outputs Status OFF The M2 output controls second motor ON The M2 output controls status lights POSITION 6 P E Stops Close Cycle OFF Activating the P E input while motors are closing causes the motors to reverse ON Activating the P E input while motors are closing causes the motors to stop but not reverse POSITION 7 P E Stops Open Cycle OFF Activating the P E input while motors a...

Page 8: ...eleased or the limit switches are reached The OPN status LED on the control board will flash at 1 second intervals to assist setting times Note when setting the OPEN and CLOSE cycle times when limit switches are used release the push button a few seconds after the limit switch cuts motor power This allows for the motors to slow down over the life of the operators without the need to adjust again V...

Page 9: ...inal MI2 Reverse close command input linked to MI3 for speed setting Terminal MI3 Closing Speed Multi Step speed command input Terminal DCM command output terminal used for common PARAMETER NUMBER PARAMETER DESCRIPTION SETTING VALUE 01 00 MAX upper Frequency Hz 70 00 01 01 Supply Frequency Hz 50 00 01 02 Max output voltage 240 01 07 Output Limit 100 01 09 Accel time 5 0 01 10 Decel time 2 5 02 00 ...

Page 10: ...ck which limit switch stops gate in each direction and adjust cams so gate will stop in the fully open and closed positions Limit switches should not switch off the gates too soon before reaching the stops and conversely not too late so the torque limiter is operating Once happy with limits settings now set the travel time Change the run set switch mode selection 1 switch to set Once in set run th...

Page 11: ...11 6 COMMISSIONING ...

Page 12: ...Gate Drive Systems Australia Gate Drive Systems Australia DELTA VDF EL ATA CB 6 DELTA VDF EL DELTA VDF EL ATA CB 6 ...

Page 13: ... arm to be released from gearbox If a magnetic lock is fitted turn off the power to the control box If an electric lock is fitted release with the electric lock key provided The gate will now open manually Ensure gate is held firm so it does not close on someone or something To engage drive turn knurled knob clockwise until tight Close and lock cover door with key ...

Page 14: ... will not run inadvertently Gate hinges in good condition and oiled greased Gate swings freely Gate stops in good condition Gate operator mounting bolts tight All arm joints lubricated and moving freely with nylock nuts tight on bolt No oil leaks from gearboxes Gearbox drive cogs tight on shafts Gearbox mounting bolts nuts tight Inside operator and control box clean Baygon Surface Spray around ope...

Page 15: ...ranty is negated and will not apply in the following circumstances A If no proof of date of purchase can be produced B If the product has been used in a manner beyond its design parameters C If the product is tampered with or repaired by personnel not authorised to do so D In respect of loss or damage caused by rough treatment E If the product is not used and maintained in accordance with instruct...

Reviews: