background image

 

15

 

9.

         

W

ARRANTY

 

a.

 

Gate Drive Systems Australia warrants that the goods manufactured by it shall be free from defect in 

manufacture for a period of 12 months from the date of invoice.  Should any fault occur within that period as a 

result of faulty workmanship or materials, Gate Drive Systems Australia at its discretion, replace the product at 

no charge to the Customer except for installation & freight.  The appropriate Serial Number must be quoted for 

all warranty claims. 

b.

 

For the goods not manufactured by Gate Drive Systems Australia, we shall pass on the manufacturers warranty 

to the Customer from the date of invoice.  It is the manufacturers discretion to repair or replace goods deemed 

to be defective as a result of faulty workmanship or materials. 

c.

 

All goods must be returned to Gate Drive Systems Australia or its representative for inspection or testing to 

assess if a claim is justified.  It is the responsibility and at the cost of the Customer, to remove & return the 

goods for inspection and freight costs are the responsibility of the Customer. 

d.

 

The warranty is negated and will not apply in the following circumstances:- 

i.

 

If no proof of date of purchase can be produced. 

ii.

 

If the product has been used in a manner beyond its design parameters. 

iii.

 

If the product is tampered with or repaired by personnel not authorised to do so.  

iv.

 

In respect of loss or damage caused by rough treatment. 

v.

 

If the product is not used and maintained in accordance with instructions or recommendations listed in 

this Installation and Maintenance Manual. 

vi.

 

In respect of loss or damage caused by an Act of God or any other cause not within the manufacturers 

control. 

e.

 

Goods returned under warranty for repair or testing will incur a charge to be fixed by the manufacturer if no 

fault is found. 

f.

 

The Customer shall bear freight charges for removing & returning the goods for inspection and for the delivery 

& installation of any replacement or repaired product from a justified warranty claim. 

g.

 

Save for the express conditions and warranties herein contained all other conditions or warranties (whether as 

the quality, fitness for purpose or any other matter) expressed or implied by statute, common law, equity, trade 

custom, usage or otherwise are hereby expressly excluded provided that nothing in these terms and conditions 

shall exclude or limit any breach or condition implied by law, the exclusion or limitation of which is not 

permitted by law. 

 

Summary of Contents for 630L series

Page 1: ...ty imported components Installation and Maintenance Manual Sliding Gate Operators Models GDS 450L 630L Range Made in Australia from Australian quality imported components A B N July N14870 Installatio...

Page 2: ...the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freel...

Page 3: ...he gate travels is in accordance with the opening and closing status LED s if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening...

Page 4: ...Precautions 5 2 Wiring Requirements 6 3 Installation Details 6 10 Electrical cabling Mechanical installation Electrical connections Operator dimensions CB 6 control board layout Inputs Outputs Mode de...

Page 5: ...ateposts or mounting structure has the necessary strength and rigidity to support the operator and the load of the opening and closing gate motion Always incorporate the appropriate Photo Electric Cel...

Page 6: ...sed positions These stops need to be engineered and installed such that they will be strong enough to stop the gate should the limits fail at any time Remove the gate operator cover and position mount...

Page 7: ...7 Operator Dimensions...

Page 8: ...ver 7 Motor 2 Limit Switch Inputs no t shown 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface 9 Pedestrian Access Co...

Page 9: ...din rail to switch the 12 volts to an electric lock if fitted The load switched by the lock output terminals must not exceed 30v AC DC 5Amps If a electro magnetic lock is used change one wire on the c...

Page 10: ...t also resets the P E triggered auto close mode so that the P E input will need to be triggered again before a P E auto close cycle will be initiated Position 5 M 2 OUTPUTS STATUS OFF The M2 output co...

Page 11: ...tor led s go out when the corresponding limit switch is activated If they are the wrong way around swap over the M1 op and cl limit wires They can be roughly set so they activate approx 500 to 800mm b...

Page 12: ......

Page 13: ...pened by hand To re engage the clutch move the gate by hand Into approx The half way position and turn the Knurled knob clockwise until it is very tight If when turning the knurled knob clockwise and...

Page 14: ...Failure to maintain equipment may result in injury or death and or damage to property and equipment Recommended maintenance to be performed on the operator and gate are as follows Operator performs o...

Page 15: ...ircumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not...

Reviews: