Connect the slave to the master unit with 2 core flex (maximum load 8Amp at 12volts) (Figure 3) 

 

 

 

Figure 3: Master/Slave connections 

 

The  units  are  set  in  the  factory  for  a  standard installation  with  the  master  placed  on  the  left  hand  side 
(from  inside  looking  out).    If  the  master  is  to  be  located  on  the  right  then  the  motor  wires  need  to  be 
reversed.  To do this, locate the connection blocks for each motor on the circuit board.  Swap the brown 
and blue wires for motor one.  Do the same for motor two (Figure 3) 

 
4.

 

The gate bracket should be positioned so that the arms are almost in a straight line when the gates are 
closed (Figure 4)  To check the location of the gate brackets, first disengage the main arm from the drive 
shaft (using the spanner provided), unscrew the bolt until the arm swings freely.  Clamp the gate bracket 
in position.  Open and close the gate to ensure the gate bracket is appropriately located. 

 

Pillar 

 

 

Figure 4: Arm position when gate closed 

5.

 

Connect Receiver Board 

6.

 

Connect power to the master operator. 

7.

 

The limit switches may now be adjusted (Figure 5).  Each unit has its own pair of cams, one to set the 
open  position  and  one  to  set  the  closed  position.    Loosen  the  screw  holding  the  cams.    Operate  the 
operator  with  the  transmitter  and  note  which  cam  controls  the  opening/closing  motion  (the  cam  lobe 
activates  a  limit  switch  to  turn  off  the  motor).    Reposition  each  cam  and  operate  the  operator  again.  
Repeat until the gates open and close to the required positions. 

 

 

Figure 5: Limit Switches 

Summary of Contents for 3

Page 1: ...1 Installation and Maintenance Manual Light Industrial Swing Gate Operators Model GDS 3 A B N 62 059 806 405 March 2017 V1 01 ...

Page 2: ...age Standard Installation 3 Side Mount Installation 5 Restricted Side Room Outswing Installation 6 Circuit Board Settings 6 Options 7 Transmitter Poor Range 8 Specifications Emergency Release Maintenance Warranty 9 ...

Page 3: ...from the operators to access the slotted fixing holes in the rear of the chassis Bend the tabs out and back against the rear of the chassis In this position they act as spacers allowing clearance for the cover 3 Position each unit on the gate pillars or posts approximately 50mm from the edge of the pillar The vertical position is found by locating the gate bracket This is best placed where there i...

Page 4: ... of the gate brackets first disengage the main arm from the drive shaft using the spanner provided unscrew the bolt until the arm swings freely Clamp the gate bracket in position Open and close the gate to ensure the gate bracket is appropriately located Pillar Figure 4 Arm position when gate closed 5 Connect Receiver Board 6 Connect power to the master operator 7 The limit switches may now be adj...

Page 5: ... the side room available In most situations this problem can be overcome by cutting down the Secondary arm the link joining the gate bracket to the Primary arm The new length can be approximated by the following procedure 1 Move the Primary arm to a position suitable for the close gate Remembering that in the closed position the Primary and Secondary arms must stop short of straight line alignment...

Page 6: ...matically close after a specific period This feature is activated by fitting a jumper across the appropriate connection block Figure 9 and adjusting the Auto Close dial to the required time delay Turning the dial anticlockwise increases the time until the gates automatically close Figure 9 Settings OVERLOAD The overloads Figure 9 are preset to maximum sensitivity i e slight pressure on the gate du...

Page 7: ...ations where the master unit is on the right hand side from inside looking out R24 sets the opening delay and R27 sets the closing delay Turning the dials anticlockwise gives the minimum delay OPTIONS PUSH BUTTON KEY PAD ETC A variety of hard wired input devices can be used to operate the Light Industrial Operators Input should be in the form of a momentary closed circuit Warning Voltage must not ...

Page 8: ...olved by using special frequency transmitters and a matching receiver These may be ordered through your supplier OTHER FAULTS Other faults may be due to incorrect settings Refer to the Settings and Options sections of this manual to ensure the settings are correct SPECIFICATIONS Dimensions Case 245mm high x 140mm wide x 335mm deep Primary arm pivot centres 550mm Secondary arm pivot centres 570mm W...

Page 9: ...ircumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not authorised to do so iv In respect of loss or damage caused by rough treatment v If the product is not used and maintained in accordance with instructions or recommendations listed in this Installatio...

Reviews: