Technical Data GDH120-Air-Split
Outlet water max. temp. (°C) A10/W35
15,9 kW / COP 3,6
Outlet water max. temp. (°C) A7/W35
14,8 kW / COP 3,3
Outlet water max. temp. (°C) A2/W35
12,1 kW / COP 3,0
Outlet water max. temp. (°C) A-7/W35
9,7 kW / COP 2,2
Starting current
22 A
Operating current
20,2 A
Operating voltage
220V 1NAC 50 Hz
Compressor
Scroll
Max. water flow
2.500 l/h
Fuse
1 x C 25 A
Refrigerant quantity (R407c)
3,2 kg
Outdoor Unit
High
900 mm
Width
950 mm
Depth
420 mm
Weight
55 kg
Sound level (distance 1 m)
54 dB
Indoor Unit
High
1.400 mm
Width
950 mm
Depth
420 mm
Weight
28 kg
Sound level (distance 1 m)
26 dB