background image

6/44

EN

The obligations stipulated in the supply agreement, our general terms and conditions of business, the 

manufacturer’s terms and conditions of supply and the statutory regulations in force at the time of contract 

conclusion apply.

1.5. COPYRIGHT

The contents of these instructions are protected by copyright. They may be used in connection with the 

operation of the system. Any other use above and beyond the aforementioned is only permitted with the 

written consent of the manufacturer.

1.6. SPARE PARTS

WARNING!

• 

Risk of injury from using incorrect spare parts!

• 

The use of incorrect or defective spare parts can result in risks for the operating staff  and in damages, 

malfunctions or total failure of the system.

• 

Only use original spare parts from the manufacturer or spare parts authorized by the manufacturer.

• 

Always consult the manufacturer if in doubt.

LOSS OF WARRANTY

• 

The manufacturer’s warranty lapses if unauthorized spare parts are used.

1.7. WARRANTY PROVISION

In principle, our "General Terms and Conditions of Sale and Delivery" shall apply. These are available to the  

customer at the latest since the conclusion of the contract.

1.8. CUSTOMER SERVICE

Please do not hesitate to provide us with information and experiences gained through use; we welcome any 

valuable input that will help to improve our products.

2. SAFETY

This section provides an overview of all the important safety aspects to ensure the protection of your staff  

and the safe and trouble-free operation of the equipment. Further safety information relating to specifi c tasks 

can be found in the sections on the individual life cycle phases.

2.1. INTENDED USE

The point of use regulator PXLHXFT is only usable for the defi ned standard gases and pressures  observing 

the given temperature range. The nominal fl ow is 20 m3/h (Air).
Intended use also includes compliance with all the information in these instructions and compliance with  

reparation, maintenance working, type label and data sheets.
Any use other than, or above and beyond, the intended use constitutes improper use.

WARNING!

• 

Danger from improper use!

• 

Improper use of the system can lead to dangerous situations.

• 

Never use the line regulator with liquid fl uids.

2.1.1. STRUCTURAL MODIFICATIONS TO THE POINT OF USE REGULATOR

Do not make any changes, additions or modifi cations to the point of use regulator without the written consent 

of the manufacturer.
Withdrawal pressure reducers that are not in perfect condition must be replaced immediately.

Clean the gas equipment and dispose of the residues

Used point of use regulator awaiting repair must be fl ushed with an inert gas (nitrogen).

Summary of Contents for PPLH0FT

Page 1: ...IG Vor Gebrauch sorgf ltig lesen Bewahren Sie die Gebrauchsanweisung f r sp teres Nachschlagen auf INSTRUCTION FOR USE GEBRAUCHSANLEITUNG POINT OF USE REGULATOR ENTNAHMEDRUCKREGLER EN DE PPLH0FT PPLHE...

Page 2: ...1 SIGNS THAT GIVE ORDERS 11 2 8 2 SIGNS INDICATING BANS 11 2 8 3 WARNING SIGNS 11 3 TECHNICAL SPECIFICATIONS 12 3 1 DIMENSION SHEET POINT OF USE REGULATOR 12 3 2 GENERAL INFORMATION 13 3 3 CONNECTION...

Page 3: ...E WORK 17 8 3 1 CLEANING 17 8 3 2 REQUIREMENTS FOR MAINTENANCE 17 8 3 3 NECESSARY MAINTENANCE 18 8 4 MEASURES FOLLOWING MAINTENANCE 18 9 TROUBLESHOOTING 18 9 1 SAFETY NOTES FOR TROUBLESHOOTING 18 10 D...

Page 4: ...ensure a basic understanding of the system and may differ from the actual version 1 2 INFORMATION ON THE POINT OF USE REGULATOR Point of use regulators of this type may only be used with the gases def...

Page 5: ...to particular risks DANGER This combination of symbol and signal word indicates an im mediately dangerous situation involving electrical current Ig noring such a warning could result in severe or fat...

Page 6: ...ormation and experiences gained through use we welcome any valuable input that will help to improve our products 2 SAFETY This section provides an overview of all the important safety aspects to ensur...

Page 7: ...d or icing THEREFORE Observe suitable temperatures Protect component from liquids from outside Protect component from dust from outside Protect component from weather conditions Grounding has to be mo...

Page 8: ...he system is mandatory in addition to the safety information in these instructions THE FOLLOWING APPLIES IN PARTICULAR The operator must be aware of the applicable work safety regulations and must per...

Page 9: ...2 4 2 UNAUTHORIZED PERSONNEL WARNING Risks associated with unauthorized personnel in the hazard and work areas can be life threatening Unauthorized individuals without the qualifications described in...

Page 10: ...hand Familiarize the staff with accident reporting first aid and emergency procedures Keep the access routes free for emergency service vehicles MEASURES IN THE EVENT OF FIRE OR ACCIDENT If there is n...

Page 11: ...nce with the requisite operating information This could result in injury Make sure all safety warning and operation information is legible at all times Immediately replace any damaged signs or labels...

Page 12: ...12 44 EN 3 TECHNICAL SPECIFICATIONS 3 1 DIMENSION SHEET POINT OF USE REGULATOR...

Page 13: ...ting mm Hose nozzle Outlet 1 8 3 8 3 6 8 10 12 4 8 6 4 8 0 Fitting inch Fitting mm Hose nozzle Outlet relief valve H0 Version FKM seat HE Version EPDM seat 1 8 3 8 3 6 8 10 12 Fitting inch Fitting mm...

Page 14: ...l The pressure can be read on the rear pressure gauge 5 TRANSPORT PACKAGING AND STORAGE TIPS AND RECOMMENDATIONS The installation and start up of this gas supply panel is normally done by the supplier...

Page 15: ...rt conditions Without exception all packaging is made of environmentally friendly material The packaging is intended to protect the individual components against transport damage corrosion and other d...

Page 16: ...4 REQUIRED QUALIFICATIONS FOR INITIAL START UP AND CYLINDER CHANGING The test protocols from the piping according to tightness and if necessary moisture and particles are available In process gas tubi...

Page 17: ...d to reflect the actual wear and tear NOTE Please contact the manufacturer if you have any questions relating to maintenance works and intervals see 1 8 for contact details Interval Maintenance work P...

Page 18: ...rial or similar 3 Make sure that safety relevant components are working perfect 9 TROUBLESHOOTING The following section describes possible causes of malfunction and how to eliminate them If malfunctio...

Page 19: ...Difference between flow pressure with gas flow and Zero Pressure without gas flow No failure nor mal operating state Heavy drop of outlet pressure Required flow to high for pressure regulator Choose...

Page 20: ...gas tanks e g N2O CO2 No failure nor mal operating state ATTEN TION keep functionality of contact gauges in mind raise quantity of pressure gas tanks This table is not exhaustive For questions and amb...

Page 21: ...included in the list of Substance of Very High Concern SVHC The most commonly used brass alloys used for bodies and other brass components contain 2 3 of lead Pb EC no 231 468 6 CAS no 7439 92 1 The l...

Page 22: ...TZ 30 2 8 BESCHILDERUNG 31 2 8 1 GEBOTZEICHEN 31 2 8 2 VERBOTZEICHEN 31 2 8 3 WARNZEICHEN 31 3 TECHNISCHE DATEN 32 3 1 MASSBLATT ENTNAHMEDRUCKREGLER 32 3 2 ALLGEMEINE ANGABEN 32 3 3 ANSCHLUSSWERTE 32...

Page 23: ...1 REINIGUNG 36 8 3 2 VORAUSSETZUNG ZUR WARTUNG 36 8 3 3 NOTWENDIGE WARTUNGSLEISTUNG 37 8 4 MASSNAHMEN NACH ERFOLGTER WARTUNG 37 9 ST RUNGEN 37 9 1 SICHERHEITSHINWEISE F R DIE ST RUNGSBEHEBUNG 37 10 D...

Page 24: ...hrung abweichen 1 2 INFORMATION ZUM ENTNAHMEDRUCKREGLER Entnahmedruckregler dieses Typs d rfen nur mit denen als Standardgas definierten Gasen verwendet werden Der maximale Arbeitsdruck f r diese Ent...

Page 25: ...sondere Gefahren aufmerksam zu machen werden in Sicherheitshinweisen folgende Symbole eingesetzt GEFAHR Diese Kombination aus Symbol und Signalwort weist auf eine unmittelbar gef hrliche Situation dur...

Page 26: ...erlischt die Herstellergarantie 1 7 GEW HRLEISTUNGSBESTIMMUNGEN Grunds tzlich gelten unsere Allgemeinen Verkaufs und Lieferbedingungen Diese stehen dem Kunden sp testens seit Vertragsabschluss zur Ver...

Page 27: ...meiden m ssen die hier aufgef hrten Sicherheitshinweise und die Sicherheitshinweise in den weiteren Abschnitten dieser Anleitung beachtet werden GEFAHR Gase k nnen lebensgef hrlich sein Gase k nnen di...

Page 28: ...e zust ndige Wartungsfirma ist unbedingt zu informieren Nie Abblaseleitungen verschlie en 2 3 VERANTWORTUNG DES BETREIBERS BETREIBER Betreiber ist diejenige Person die das Ger t zu gewerblichen oder w...

Page 29: ...n zu erkennen 2 4 2 UNBEFUGTE WARNUNG Lebensgefahr f r Unbefugte durch Gefahren im Gefahren und Arbeitsbereich Unbefugte Personen die die hier beschriebenen Anforderungen nicht erf llen kennen die Gef...

Page 30: ...griffbereit aufbewahren Personal mit Unfallmelde Erste Hilfe und Rettungseinrichtungen vertraut machen Zufahrtswege f r Rettungsfahrzeuge freihalten MASSNAHMEN BEI FEUERAUSBRUCH UND UNF LLEN Wenn kei...

Page 31: ...ndige Bedienhinweise nicht befolgt werden k nnen Dadurch besteht Verletzungsgefahr Alle Sicherheits Warn und Bedienungshinweise in stets gut lesbarem Zustand halten Besch digte Schilder oder Aufkleber...

Page 32: ...152 152 Breite mm 118 118 H he mm 374 374 3 3 ANSCHLUSSWERTE Angabe Wert Einheit Eingang 1 8 3 8 3 6 8 10 12 4 8 6 4 8 0 Klemmring z llig Klemmring mm Schlaucht lle mm Ausgang 1 8 3 8 3 6 8 10 12 4 8...

Page 33: ...vom Eingangsdruck bar 3 5 BETRIEBSBEDINGUNGEN UMGEBUNG Angabe Wert Einheit Temperaturbereich 20 bis 60 C Relative Luftfeuchte max 98 4 AUFBAU UND FUNKTION 4 1 AUFBAU PPLH0FT PPLHEFT PSLH0FT PSLHEFT 4...

Page 34: ...TIPPS UND EMPFEHLUNGEN Jeden Mangel reklamieren sobald er erkannt ist Schadensersatzanspr che k nnen nur innerhalb des Gew hrleistungszeitraums geltend gemacht werden 5 3 VERPACKUNG Die einzelnen Pac...

Page 35: ...nem maximalen Druck von 15 bar mit Schlaucht lle erh ltlich Durch die kegelf rmige Form der T lle l sst sich der Schlauch einfach aufstecken 6 4 VORAUSSETZUNG ZUR ERSTINBETRIEBNAHME Die Pr fprotokolle...

Page 36: ...sintervalle entsprechend den tatsachlichen Verschlei erscheinungen verk rzen HINWEIS Bei jeglichen Fragen bez glich Wartungsarbeiten und Wartungsintervallen kontaktieren Sie den Kunden service siehe K...

Page 37: ...TSPANNUNGSSTATION DES DRUCKREGLER ODER DES VENTILS DIE FOLGENDEN SCHRITTE DURCHF HREN 1 Sicherstellen dass alle verwendeten Werkzeuge Materialien und sonstige Ausr stungen aus dem Arbe itsbereich entf...

Page 38: ...eg Abblaseventil ffnet Leckage im Druckregler sitz Reparatur durch Herstel ler Leichter Hinter druckanstieg Abblaseventil ffnet nicht Vordrucka bfall Kein Fehler normaler Be triebszustand Leichter Hin...

Page 39: ...n Druck reglers f r ge forderten Druck Durchfluss Keine Ver nderung der Ventilsteu erung trotz drehen des Handrades Handrad defekt durch zu hohes Drehmo ment Spin del defekt Gewinde defekt Reparatur d...

Page 40: ...rialien entfernen und umweltgerecht entsorgen Anschlie end Baugruppen und Bauteile fachgerecht reinigen und unter Beachtung geltender rtlicher Arbeitsschutz und Umweltschutzvorschriften zerlegen WARNU...

Page 41: ...ponenten Schmier und andere Hilfsstoffe von zugelassenen Fachbetrieben entsorgen lassen Im Zweifel Auskunft zur umweltgerechten Entsorgung bei der rtlichen Kommunalbeh rde oder speziel len Entsorgungs...

Page 42: ......

Page 43: ......

Page 44: ...esk republika http www gcegroup com Doc Nr IFU PXLHX DOI 2022 09 21 Rev 00 TI A5 CB V1 UNITED STATES OF AMERICA CHINA INDIA RUSSIA MEXICO SWEDEN POLAND GERMANY FRANCE SPAIN ITALY IRELAND UNITED KINGDO...

Reviews: