BA100
15
UK
The settings are stored during the rest phase (door closed).
DIP
FUNCTION
STATUS
DIP 1
ON
OFF
DIP 2
ON
OFF
DIP 3
ON
OFF
DIP 4
ON
OFF
PHOTO 1 DISABLED
PHOTO 1 ENABLED
PHOTO 2 DISABLED
OPENING LIMIT SWITCH ENABLED
OPENING LIMIT SWITCH DISABLED
CLOSING LIMIT SWITCH ENABLED
CLOSING LIMIT SWITCH DISABLED
PHOTO 2 ENABLED
DEFAULT SETTINGS (DIP SWITCH SW2)
DIP 1 ON: PHOTO 1 DISABLED
DIP 2 ON: PHOTO 2 DISABLED
DIP 3 ON: CLOSING LIMIT SWITCH DISABLED
DIP 4 ON: OPENING LIMIT SWITCH DISABLEDSA APERTURA
TRIMMER ADJUSTEMENT
The trimmers TR1, and TR4 can be adjusted also during gate movement and thus the effect immediately
checked. The trimmers TR2, TR3 and TR5 are stored only during the rest phase (gate closed).
Trimmers Function Description
TR1
SLOW
Adjusts the DECELERATION level. Turning the trimmer clockwise the gate speed/force is increased)
NB. With an electromechanical motor (DIP 5 OFF) the trimmer is uninfluential and deceleration will be fixed.
TR2
CLOSE
Adjusts the CLOSING TIME from 2 to 100 seconds if JP2 is open. The value is increased by turning the trimmer clockwise.
Adjusts the CLOSING TIME from 2 to 200 seconds if JP2 is closed. The value is increased by turning the trimmer clockwise.
TR3
Adjusts the PAUSE TIME from 2 to 200 seconds. The value is increased by turning the trimmer clockwise.
PAUSE
TR4
FORCE
Adjusts the motor FORCE level. The force is increased by turning the trimmer clockwise.
NB. IN CASE OF HYDRAULIC OPERATORS THE FORCE MUST BE AT MAXIMUM
TR5
OPEN
Adjusts the OPENING TIME from 2 to 100 seconds if JP1 is open. The value is increased by turning the trimmer clockwise.
Adjusts the OPENING TIME from 2 to 200 seconds if JP1 is closed. The value is increased by turning the trimmer clockwise.
DEFAULT SETTINGS
TRIMMERS TR1, TR2, TR3, TR4, TR5 are adjusted to halfway their travel.
FINCTION PROGRAMMING (DIP SWITCH SW2)