GBC StreamWire
07/23/2020
General Procedures and Information
6-7
GP 6.2 User Interface Procedures
The following section describes the options contained in the eWire User
Interface. The user interface can be accessed by pressing the up or down
arrows on the LCD panel. If jam messages are displayed on the screen
then press down to access the user interface
GP 6.2.1.1 Alignment Setting Adjustment Procedure
Do the following to change the Alignment. Changing the alignment setting
will shift the nominal centerline of the sheets toward the front or the rear
of the eWire.
From the top level screen, press either the up arrow button or the
down arrow button.
READY
TO BIND
This displays the SETTINGS - INFORMATION screen
SETTINGS
INFORMATION
Select SETTINGS to enter the setting select menu.
Select ALIGNMENT to enter the alignment adjustment menu.
Press the up arrow or down arrow to change the alignment setting to
the desired value (range -2.0 mm to +2.0 mm). Record the initial
value so you have a reference point to base future adjustments on.
ALIGNMENT OFFSET
0.0 mm
Press the OK/ENTER button when the desired value is displayed for the
Alignment. This will return you to the SETTINGS menu.
Select EXIT and press OK/ENTER to return to the top level menu.
GP 6 .2.1.2 DEFLECTOR Procedure
Refer to GP 6.3.7 for DEFLECTOR Procedure
GP 6.2.2
Closing Setting Adjustment Procedure
Do the following to select the desired closer travel. A higher number
indicates increased close/crimp of element. A lower number will cause the
twin loop element to be crimped less.
Note: Changing the Closing Setting effects only the size that is currently
installed. For example, if the A size spool is currently loaded, changing
the Closing value will not have any impact on the settings for other sizes.
Note: It is recommended to increment Closing Settings by only one value
at a time. Adjusting in larger increments may cause over-adjustment.
From the top level screen, press either the up arrow button or the
down arrow button.
READY
TO BIND
This displays the SETTINGS - INFORMATION screen
SETTINGS
INFORMATION
Select SETTINGS to enter the setting select menu.
Select CLOSING to enter the closing depth adjustment menu.
Press the up arrow or down arrow to change the closing setting to the
desired value (range -5 to +5)
CLOSING
1
Press the OK/ENTER button when the desired value is displayed for the
Closing. This will return you to the SETTINGS menu.
Select EXIT and press OK/ENTER to return to the top level menu.
Summary of Contents for StreamWire
Page 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Page 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Page 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Page 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Page 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Page 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Page 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Page 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Page 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Page 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Page 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Page 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Page 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Page 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Page 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Page 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Page 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...