background image

Ricoh StreamPunch Pro, Pro EX & MP Installation Manual 

4

3.2 

SR4050 & SR4080 Finisher 

 

Follow the same steps as in 3.1 but in step a) connect the 7 pin connector into CN138 on the finisher 
board. 
 
d) There are two entrance paper guides provided 
with the StreamPunch. Use the shorter paper 
guide measuring about 12” long when used in 
conjunction with the SR4050 finisher. Install the 
paper guide, using the size #8 screws provided, 
to the lower entrance guide of the StreamPunch. 

 

Go to Section 4 to complete the installation. 
 

3.3 

SR5020, SR5030, SR5040, SR5050, SR5060

 

Finishers 

 

Follow the same steps as in 3.1 but in step a) connect the 7 pin connector into CN110 on the finisher 
board. 
 
d) There are two entrance paper guides 
provided with the StreamPunch. Use the 
longer paper guide measuring about 14” long 
when used in conjunction with the SR5020, 
SR5030 or SR5040 finishers. Install the 
paper guide, using the size #8 screws 
provided, to the lower entrance guide of the 
StreamPunch. 
 
If installing the StreamPunch directly downstream from the Pro C651/C751 EX or Pro C751, contact 
your local service representative to obtain the correct entrance guide. 
 
Go to Section 4 to complete the installation. 
 

3.4 

SK5010 High Capacity Stacker 

 

Follow the same steps as in 3.1 but in step a) connect the 7 pin connector into CN150 on the finisher 
board and in step b) replace the shorter finisher to printer cable with the longer one provided, 
plugging the 8 pin cable in to loose connector and the 9 pin into CN101 on the finisher board. 

 

There are two lower exit guides that can be used with the StreamPunch. The standard 90 degree 
bend is used for most configurations and comes ready installed. When the SK5010 is installed 
directly downstream from the StreamPunch, the angled guide shown below should be fitted in place 
of the 90 degree guide. The angled exit guide is provided with the installation kit. 

 

 

Standard 90 
degree exit guide 

Angled 
exit guide 

Lower exit 
guide 

Summary of Contents for Ricoh StreamPunch Pro

Page 1: ...1 Recommendations and Pre requisites 2 2 Unpacking 2 3 Cable Connections 2 4 Installing the Sound Deadening Foam 5 5 Docking Bracket Installation 7 6 Leveling Height Adjustment 8 7 Final Steps 9 Part...

Page 2: ...DO NOT lift using the front door panel Retain the smaller accessory box it contains parts required for correct installation of the StreamPunch Inspect for any concealed damage to the unit If there is...

Page 3: ...from step a into the right side of the StreamPunch Plug the free end of the cable from step b into the connector on the printer d There are two entrance paper guides provided with the StreamPunch Use...

Page 4: ...he paper guide using the size 8 screws provided to the lower entrance guide of the StreamPunch If installing the StreamPunch directly downstream from the Pro C651 C751 EX or Pro C751 contact your loca...

Page 5: ...pped loose for field installation These are not attached at the factory to avoid compression and or damage during shipping To install simply peal the back off to reveal the adhesive using the followin...

Page 6: ...per Entrance Side Printer Side Apply one of the two remaining long strips to the right side of the printer side of the StreamPunch as shown Apply the last remaining short strip to the top cover edge o...

Page 7: ...the bottom corner Install as shown with the bracket marked R on the right side facing you as you look at the exit side of the upstream device Install the bracket marked L on the left side facing you...

Page 8: ...pstream of the SK5000 the StreamPunch will need to be lowered by approximately 5mm Follow the same adjustment procedure as in Section 6 2 and use the table below for a reference height Finisher Refere...

Page 9: ...ro C651 751 EX Pro C751 OFF ON ON ON ON OFF ON OFF MP6002 7502 9002 OFF ON ON OFF ON ON OFF OFF MP C8002 Pro C5100s OFF ON ON OFF ON OFF ON OFF Pro 8100S 8110S 8120S OFF ON ON OFF OFF OFF ON OFF 7 3 E...