(THE FOLLOWING NOTE APPLIES ONLY
TO THE UNITS RATED 115V 60HZ.)

This equipment has been tested and found
to comply with the limits for a Class A
digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference when the equipment
is operated in a commercial environment.
This equipment generates, uses, and can
radiate radio frequency energy and, if not
installed and used in accordance with the
Operator Manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential
area is likely to cause harmful interference
in which case the user will be required to
correct the interference at his/her own
expense. 

CAUTION: CHANGES 
OR MODIFICATIONS NOT
EXPRESSLY APPROVED 
BY GENERAL BINDING
CORPORATION COULD VOID
YOUR AUTHORITY TO OPERATE
THE EQUIPMENT.

This Class A digital apparatus meets all
requirements of the Canadian Interference-
Causing Equipment Regulations. 

By purchasing the PF-3200, you have
invested in a highly capable binding
machine that will give you years of reliable
service. To help protect this investment be
certain to take advantage of the GBC
Equipment Maintenance Agreement
(EMA). The EMA provides your PF-3200
with proper ongoing maintenance and
care, helping to ensure the years of quality
performance and long life built into the
machine. Without an EMA, a charge for
time and labor would result from every
normal maintenance or repair service call.
An EMA for your PF-3200 eliminates this
possibility by providing you with a low,
fixed annual cost for protecting your
valuable machine investment. For full
details about purchasing an EMA, contact
your local GBC Branch Office or contact:

General Binding Corporation
500 Bond Street
Lincolnshire, IL 60069

Or Call: 1-800-790-7787

(THE FOLLOWING NOTE APPLIES ONLY
TO THE UNITS RATED 220V 50HZ.)

CAUTION: WHEN CHOOSING A
DETACHABLE LINE CORD FOR
USE WITH YOUR PF-3200,
ALWAYS OBSERVE THE
FOLLOWING PRECAUTIONS:

The cordset consist of three parts; the
attachment plug, cordage and appliance
inlet. Each of these components must
have European regulatory approvals for
safety.

The following minimum electrical ratings
for the specific cordset are published for
safety purposes. DO NOT USE
CORDSETS THAT DO NOT MEET THE
FOLLOWING MINIMUM ELECTRICAL
REQUIREMENTS.

PLUG: 3 ampere, 250 volts, 50/60 Hz,
Class 1, 3 conductor, European safety
approved.

CORDAGE: Type H03VV-F3G0.75,
Harmonized   (  < HAR >  ).  The “< >”
symbols indicate cordage approved to
appropriate European standard (NOTE:
“HAR” may be substituted for approval
mark of European safety agency which
approved the cordage. An example would
be “ < VDE > ”.)

APPLIANCE CONNECTOR: 3 ampere,
250 volts, 50/60 Hz, European safety
approved, Type IEC 320.  The cordset
shall not exceed 3 meters in length.  A
cordset with component electrical ratings
greater than the minimum specified
electrical ratings may be substituted.

MAIN CORDSET SELECTION

FCC NOTE

EQUIPMENT MAINTENANCE AGREEMENT

Summary of Contents for PF3200

Page 1: ...Operation Manual Perfect Binder Model No PF3200...

Page 2: ...the PF 3200 Binder only for its intended purpose of binding paper and covers according to the indicated specifications Before operating the machine make certain that the PF 3200 is placed on a secure...

Page 3: ...an EMA a charge for time and labor would result from every normal maintenance or repair service call An EMA for your PF 3200 eliminates this possibility by providing you with a low fixed annual cost f...

Page 4: ...eanwhile the LED DISPLAY of the control panel will display and flash the STOP symbol 2 Correct the problem Then turn the EMERGENCY stop button to the right in order to reset the machine The START LED...

Page 5: ...255 LBS 116 Kg Machine Dimension 46 L x 22 W x 15 H 1150x560x370mm SPECIFICATIONS Name Specification Quality Cover Sheet Holder 1 Bottom Cover 1 Screw Driver 6 150mm 1 Hex Wrench 0 16 4mm 1 Hex Wrenc...

Page 6: ...clamp station as shown Then reinstall the screws in clamp station Step 2 Remove two red shipping brackets that are located around the nipping station as shown Step 3 Slide in the glue draining tray un...

Page 7: ...Operating status 3 Perform self test and stir the hot melt glue 4 Error messages Clears the display counter for books bound Displays the current total amount of binding Indicates the START button is r...

Page 8: ...temperature has reached the working temperature PF 3200 performs the self test and stirs the melting glue 6 PF 3200 is ready for bookbinding and set to MANUAL mode for your desired operation At this...

Page 9: ...3200 and the LED display of the control panel will display and flash LOAD COVER 3 Center the cover sheet and adjust the side guide Measure the width of the book plus half the thickness of the spine Th...

Page 10: ...tion Having completed one bound book the LED display of control panel will count once for the total binding amount as shown Then the control panel will display and flash LOAD BOOK for binding next boo...

Page 11: ...splay again C Press the START button The LED DISPLAY of control panel will show the sign The clamp station will move to the left side of PF 3200 and will remain there 4 Place the cover sheet onto the...

Page 12: ...ce for the total binding amount as shown The PF 3200 will flash LOAD BOOK display 5 Place the same thickness of book block onto the clamp as the label instructions on the clamp The clamp station will...

Page 13: ...ion will automatically move back to the right position and display BIND C Wait for a few seconds until the LED display of control panel displays PUSH OPEN as shown 4 Then press the OPEN button to open...

Page 14: ...lue tank to the working temperature then the READY LED will be lit and waiting for your desired operation Note that you have to wait a few minutes when LED displays WARM00 status The glue tank of PF 3...

Page 15: ...OR Too much glue on both sides Nail head OR Min Max GLUE SCRAPER SPINE OF BOOK MAX Min Max GLUE SCRAPER SPINE OF BOOK MIN CAUTION GREAT CARE MUST BE TAKEN WHEN HANDLING HOT MOLTEN GLUE BE SURE NOT TO...

Page 16: ...lue that might be on the nipping plates and plate surfaces 4 Press the START and CLEAR keys the clamp station will return to its home position Open the clamps to the maximum position 5 Turn the PF 320...

Page 17: ...lowed by START button to recover the factory settings CAUTION WE ONLY RECOMMEND YOU TO CHANGE TR1 SETUP FOR TIMERS Name Default Time Range Description TR1 4 sec 2 0 10 sec TR2 1 sec 0 5 5 sec TR3 2 se...

Page 18: ...General Binding Corporation Northbrook IL 60062 4195 http www GBC com Printed in the U S A Rev A1 GBC Part 7301322...

Reviews: