Page 8 - 3
Maintenance
Digital Feeder Operation and Maintenance Manual
© GBC Pro - Tech February 2000
8.3 Cleaning the control
panel
ELECTRICAL
S H O C K
Remove power from the feeder before
cleaning. You can be severely shocked, killed
or cause a fire.
a) Use only a slightly damp ( water only ) non
abrasive cloth.
ELECTRICAL
S H O C K
Do not use liquid or aerosol cleaners on the
feeder. Do not spill liquid of any kind on the
feeder. You can be severely shocked, killed
or cause a fire. Use only a damp cloth for
cleaning unless other wise specified.
8.4 Emptying the water trap
The water trap on the feeder is designed to catch
the overflow of moisture from the compressor. This is the
last prevention of moisture from getting to the pneumatic
components.
It is essential that this water trap be emptied on a
daily to weekly basis depending on usage. If your
compressor in not equipped with a moisture trap device,
this procedure should be performed daily.
a) With a terry cloth towel, press up on the relief
pin below the water trap bubble.
Relief pin
Water trap
bubble
Air filter / regulator
b) If an excessive amount ( more than a 1/5 full )
hold a cup under the relief pin to catch most of
the water.