9
EN
of the red and green indicator lights. When a failure
occurs, remove the battery and then insert it into the
charger again. If the failure continues, change with
a new battery. If the new battery can be charged,
then the old battery maybe damaged. If the charging
indicator lights indicate same failure as before while
changing with a new battery, then the charger maybe
damaged, take the charger to be repaired by qualified
serviceman.
5
4
3
2
1
1.negative pole
2.positive pole
3.indicator light
4.bettery pack
5.charger
Continuous Use
If the tool is operated continuously until the
battery cartridge has discharged, allow the tool to
rest for 15minutes before proceeding with a fresh
battery.
MAINTENANCE
CAUTION:
Always be sure that the tool is switched
off and unplugged before attempting to perform
inspection or maintenance.
Cleaning air vents
Always keep air intake and outtake clean. Clean
them regularly or if they are jammed.
Inspecting the mounting screws
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
Cleaning
Clean dust and debris from vents. Keep the machine
handles clean, dry and free of oil or grease)
●
Cleaning dustproof net
Pry the dustproof net out from the two places in with
a flat blade screwdriver and clean the net to allow the
air to circulate.
Clean up the dustproof net when it is clogged with
dirt and foreign matters to protect damage from the
machine.
2
1
※
To maintain product SAFETY and RELIABILITY,
repairs, any other maintenance or adjustment should
be performed by authorized centers, always using
original replacement parts.
For battery tools:
Ambient temperature range during operation and
storage: 0
℃
- 45
℃
.
Recommended ambient temperature range during
charging: 5
℃
- 40
℃
.
Charger
Battery Pack
Model
GC1000
GC1001
GC1040
GC1050