2
Gaylord Ventilator model numbers are made up of an alphabetic prefix followed by a series of
alphabetic and/or numeric suffixes to designate the style of the ventilator and various options.
Sequence of model numbers is as follows.
1.______ 2.______ 3._______ 4._______
5._________
6.________
7. _______
Series
Damper
Style
Front lip
Apron Design
Canopy Front Spark
Type
Design
(If Applicable)
Height Option Arrestor
Option
(If Applicable)
Explanation of Prefixes and Suffixes
1.
Series
"
ENER
G
LINK"
EL……………………..
Non water-wash ventilator with UL 1046 filters
ELX
........................... Non water-wash ventilator incorporating XGS Extractors
ELX-UV
.................... Non water-wash ventilator incorporating XGS Extractors and UV Lamps
ELX-ENL
……………. Non water-wash ventilator incorporating XGS18 Enlarged extractor.
2.
Damper Type
GBD
.......................... Gaylord Balancing Damper. Has a mechanical balancing damper located at the duct collar
(Standard)
GFBD
....................... Gaylord Fire Balancing Damper. Has an electric, thermostatically activated Fire/Balancing
damper located at the duct collar and back draft feature.
325°F Thermostat standard
.
GEBD
....................... Gaylord Electric Balancing Damper. Has an electric balancing damper located at the duct collar
with back draft feature.
FDD
…………….. ...... Weighted Fuse Link activated damper located at the duct collar.
280°F Fuse link standard
.
ND
............................ No Damper
3.
Style
Blank
........................ Wall Mounted canopy style
CL
............................. Island style for single line of cooking equipment using one extraction chamber (
Light-Medium
Duty only
)
BBC-CL
.................... Island style for single line of cooking equipment using one extraction chamber with one common
exhaust duct (
Light-Extra Heavy Duty
)
BBC
......................... Island style for double line of cooking equipment using one extraction chamber. Has one
exhaust duct.
BB
........................... Island style for double line of cooking equipment using two extraction chambers. Has two
separate exhaust ducts.
4.
Front Lip Design
(Front lower edge of the hood)
Blank
......................... Facetted front design with 6 inch return flange.
(3 Break or greater 90° at front lip)
C
............................... Chamfer (6 x 6) with 6 inch return flange
S
............................... Square front with 12" “Super Capture” lip
5.
Apron Design Designation
Blank
......................... Rear Wall to be added below hood
A
............................... Hood to have an Apron, which will terminate at the bottom lower edge of the canopy.
UW
............................ Utility Wall to be added below hood.
Note: DCR-WM model Utility Distribution System to be
added as a separate piece of equipment.
6.
Canopy Front Height Option
Blank
......................... 30 inch or greater Canopy Height
MP
............................
Medium Profile
- 24 inch Front height hoods. Extractors range from 24 to 30 inches tall.
Models containing UV are required to have 30 inch tall extractors.
LP
.............................
Low Profile
- 12 inch to 23 inch front height. Extractors range from 24 to 30 inches tall.
7.
Spark Arrestor
(If Applicable – 700
°
F Applications only)
SPA
.......................... Uses “XGS-SPA” or “XGS18-SPA” Spark Arrestor Extractors – for solid fuel applications.
Summary of Contents for ELX SERIES
Page 12: ...9 9 GFBD INTERNAL WIRING SINGLE SECTION FIGURE 16 GFBD GEBD Internal Wiring Diagram ...
Page 13: ...10 10 GFBD EXTERNAL WIRING MULTIPLE SECTION FIGURE 16B GFBD External Wiring Diagram ...
Page 25: ...22 20142 20143 20163 20139 20140 19289 20144 76047 UV MODULE PARTS ...
Page 26: ...23 UV HOOD WIRING BOARD SCHEMATIC ...
Page 28: ...25 ELX GBD OR ND NO UV WIRING DIAGRAM ...
Page 29: ...26 ELX GFBD NO UV WIRING DIAGRAM ...
Page 30: ...27 ELX UV GBD ND WIRING DIAGRAM ...
Page 31: ...28 ELX UV GFBD WIRING DIAGRAM ...
Page 32: ...29 ELX UV GFBD WITH GPC 6000D WIRING DIAGRAM ...